Secure the shower to
the wall mount, ensuring
filters are in place.
2
5
Identify the
required position of
the valve and prepare
the water supply pipes.
Supply pipes should
be 150mm apart.
Using the backplate
supplied with the
wall mount, mark
and drill holes.
Secure the isolators
onto the backplates;
ensuring the olives
are positioned
over the pipework
correctly.
Secure the shrouds against
the rubber fixing plates.
4
3
1
Installation
Rotate the shroud until
the opening aligns with
the isolation screw.
Turn the screw to isolate
the water. Reverse the
process when turning
the water back on.
1
Isolation
2
Remove the concealing
cap from the shroud.
Secure the rubber and metal
backplates into place.
21mm
21mm
REMEMBER
To service
your
product!
Operation
REMEMBER
hot on the left,
cold on the
right
IMPORTANT
Pack Contents
150mm
Centres
1.0
5.0
Pressure
BAR
0.2
4.0
2.0 3.0
Pressure
BAR
1.0
5.0
0.2
4.0
2.0
3.0
60°C
65°C
Specifications
Maximum Static Pressure:
10.0 bar
Inlet Water Temperature
15mm
Compression
Inlet Connections
Min:
0.2 bar
Max:
5.0 bar
Working Pressures
The inlet hot water must
be at least 10°C above the
required blend temperature.
Factory pre-set
42°C
Inlet Dimensions
5°C
25°C
Cold Water Supply
Min:
5°C
Max:
25°C
Hot Water Supply
Tools You’ll Need
Flat head
Screwdriver
Cross head
Screwdriver
Hexagonal Keys
Socket Spanner
Pipe Cutter
Pencil
Drill
Adjustable
Spanner
Installation Instructions
& User Guide
Please leave these instructions
with the end user
Product Code: QD SHXSMFF C (D3)
All products manufactured and supplied by Bristan are safe to use provided that
they are installed, operated and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999 and
current by-laws. For full Installation Requirements & Notes (IRN) please
visit
wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of future
maintenance.
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder etc.
This product must not be modified in any way as this will invalidate the
guarantee.
Full access must be made available for future maintenance/servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires,
cables or water supply pipes. This can be checked with the aid of an
electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
If in doubt, contact a registered plumber or your Local Water Authority or
the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Prior to Installation
60-65°C Recommended
Hot
Hot
Cold
Cold
On
On
Off
Off
x2
x2
x1
x1
x1
x1
x1
x1
x1
x1
150mm C
entr