Secure the shower to  

the wall mount, ensuring  

filters are in place.

2

5

         Identify the    

   required position of 

the valve and prepare 

the water supply pipes. 

Supply pipes should  

be 150mm apart.

Using the backplate 

supplied with the  

wall mount, mark  

and drill holes.

Secure the isolators 

onto the backplates; 

ensuring the olives 

are positioned 

over the pipework 

correctly.

Secure the shrouds against  

the rubber fixing plates.

4

3

1

Installation

Rotate the shroud until 

the opening aligns with 

the isolation screw.

Turn the screw to isolate 

the water. Reverse the 

process when turning  

the water back on.

1

Isolation

2

Remove the concealing 

cap from the shroud.

Secure the rubber and metal 

backplates into place.

21mm

21mm

REMEMBER 

To service 

your 

product!

Operation

REMEMBER 

hot on the left, 

cold on the 

right

IMPORTANT

Pack Contents

150mm

Centres

1.0

5.0

Pressure

BAR

0.2

4.0

2.0 3.0

Pressure

BAR

1.0

5.0

0.2

4.0

2.0

3.0

60°C

65°C

Specifications

Maximum Static Pressure: 

10.0 bar

Inlet Water Temperature

15mm 

Compression

 

Inlet Connections

Min: 

0.2 bar

Max: 

5.0 bar

Working Pressures

The inlet hot water must 

be at least 10°C above the 

required blend temperature.

Factory pre-set

42°C

Inlet Dimensions

5°C

25°C

Cold Water Supply

Min: 

5°C

 Max: 

25°C

Hot Water Supply

Tools You’ll Need

Flat head  

Screwdriver

Cross head  

Screwdriver

Hexagonal Keys

Socket Spanner

Pipe Cutter

Pencil

Drill

Adjustable 

Spanner

Installation Instructions 

& User Guide

Please leave these instructions 

with the end user

Product Code: QD SHXSMFF C (D3)

All products manufactured and supplied by Bristan are safe to use provided that 
they are installed, operated and receive regular maintenance in  
accordance with these instructions. 

This product needs to be installed in accordance with, and meet the  
requirements of the Water Supply (Water Fittings) Regulations 1999 and  
current by-laws. For full Installation Requirements & Notes (IRN) please  
visit 

wras.co.uk/directory. 

Isolation valves must be fitted to the inlet water supplies to ensure ease of future 
maintenance.  

Before installing this product the water supply must be thoroughly flushed in 
order to remove any swarf, solder etc. 
 
This product must not be modified in any way as this will invalidate the  
guarantee. 

Full access must be made available for future maintenance/servicing purposes.

Before drilling into walls, check that there are no hidden electrical wires,  
cables or water supply pipes. This can be checked with the aid of an  
electronic detector. 

If power tools are used do not forget to:  
 

- Wear eye protection

 

- Unplug equipment after use

If in doubt, contact a registered plumber or your Local Water Authority or  
the Secretary of the Institute of Plumbing, address as follows:-

The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791

Prior to Installation

60-65°C Recommended

Hot

Hot

Cold

Cold

On

On

Off

Off

x2

x2

x1

x1

x1

x1

x1

x1

x1

x1

150mm C

entr

es