Product features

Water Efficient

When the users hands enter the sensing 

range, the indicator light in the sensor 

will illuminate. Water will flow out 

immediately until the user draws their 

hands back from the sensor.

The water will automatically stop after  

a maximum of 30 seconds 

±

 5 seconds 

to avoid wasting water. If more water is 

required wait 3 seconds and then place 

hands back in the sensing range.

Temperature Control

Manual temperature control lever allows 

users to set preferred temperature. 

 

More Hygienic 

The proximity sensor removes the need to 

touch the spout body, reducing the spread 

of germs and reducing the chance of 

cross infection. 

Battery Override

In the event of a power failure, the product 

will automatically switch to battery 

operated mode to ensure the spout 

continues to function. The tap can also 

operate on the battery alone if no mains 

power source is available.

Low Battery Warning

When the batteries run low and the 

power falls below 3.9V the sensor light 

will flicker to indicate the batteries are 

running low and need replacing. 

When the batteries are exhausted the 

sensor light will not light up.

Need help? 

Give us a call on 0844 701 6273 and speak to one of our trained advisers. 

        

Sensor

Содержание IRBS4-BN

Страница 1: ...reference Installer when you have read these instructions please ensure you leave them with the user Installation Instructions and User Guide Infrared Temperature Control Automatic Basin Spout Models...

Страница 2: ...tive requirements Providing they are installed correctly and receive regular maintenance in accordance with these instructions your user experience will not be affected For a safe and successful insta...

Страница 3: ...ns Remove all packaging and check the contents for damage before starting installation Before starting any installation please consider the following before drilling into walls check that there are no...

Страница 4: ...er temperature of 60 C is considered sufficient to meet all normal requirements and will minimise the build up of limescale in hard water areas This product should be installed in compliance with the...

Страница 5: ...ienic The proximity sensor removes the need to touch the spout body reducing the spread of germs and reducing the chance of cross infection Battery Override In the event of a power failure the product...

Страница 6: ...isers Specifications Operating Pressure Range Min 1 0 Bar Max 5 0 Bar Maximum Static Pressure 10 Bar Inlet Water Supply Temperature Range 5 C 45 C Power Supply AC 220V 240V 50 60HZ DC 6V 4 x AA alkali...

Страница 7: ...a switched fused spur off the ring main The wires in the mains lead are coloured in accordance with the following code Blue Neutral Brown Live As the colours of the wires in the mains lead of this app...

Страница 8: ...ner 3 Connect Sensor Cable See Electrical Connections installation on page 10 4 Connect Water Supplies Before connecting the water supply to the spout flush through the pipework to ensure removal of d...

Страница 9: ...es will override the mains power supply to ensure the spout continues to function 1 Insert Batteries Insert 4 x AA batteries into the battery box ensuring they are inserted the correct way Note Only u...

Страница 10: ...the factory supplied power cable Power Sensor Cable Connection Connect the transformer cable to the sensor and battery box connectors Attach The Wall Bracket Attach the wall bracket to the wall by us...

Страница 11: ...sure it does not bend sharply and kink or twist See below for recommended ways to fit the flexible connecting hose Important Failure to follow these guidelines may result in poor performance and damag...

Страница 12: ...owing If the user requires more water remove hands from the sensing range and wait 3 seconds then place the hands back into the sensing range and the water will flow again Note The sensing range for a...

Страница 13: ...s or disinfectants or those containing alcohol hydrochloric acid or phosphoric acid Cleaning the Inlet Filter Before carrying out any maintenance turn off the mains water supply and close any isolatin...

Страница 14: ...sponsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling...

Страница 15: ...ter Inlet water supply pressure too low Refer to Specifications section on page 6 No power to the power supply box No Mains power to the power supply box Connect power supply cable Refer to Electrical...

Страница 16: ...get wet Contact Bristan Customer Services on 0844 701 6273 Batteries are exhausted Replace batteries Short cycles of batteries Incorrect batteries fitted Replace batteries Ensure batteries are 1 5V AA...

Страница 17: ...lease use this space to add any notes you or your installer may have regarding the plumbing system installation of this product Need help Give us a call on 0844 701 6273 and speak to one of our traine...

Страница 18: ...e original purchaser with proof of purchase The installation must allow ready access to all products for the purpose of inspection maintenance or replacement Repair under this guarantee does not exten...

Страница 19: ...nce checks or recommend the best course of action to fix any problems with a product Expert advice Find easy to follow how to video guides and technical FAQs online at www bristan com Our guides take...

Страница 20: ...B78 1SG Web www bristan com Email enquire bristan com A Masco Company Part Number FI Infrared Ext 2 Issue D1 Useful contact details Customer Service 0844 7016273 Customer Service Email Customercare b...

Отзывы: