Adjusting the Temperature 

The mixer tap has been factory set 

with equal (balanced) hot and cold 

water supply pressures with the hot 

water supply at 65˚C.
If your operating conditions are 

different from those above, the outlet 

water temperature may differ from 

the factory setting.
If required the mixer tap can be 

re-calibrated to suit your own 

temperature requirements.
Turn the temperature control anti-

clockwise (hotter) fully until it stops 

and check the temperature of the 

water with a thermometer.  

If the temperature is not correct,  

re-calibrate the mixer tap:

1. Turn the flow of water on.
2. Remove the temperature control 

lever. Remove the cap, undo the grub 

screw and carefully remove the lever 

handle.
3. Insert a 2.5mm hexagonal key 

into the temperature control screw, 

located at the centre of the cartridge 

spindle. 
Turn clockwise to decrease the 

temperature and anti-clockwise to 

increase the temperature. 
Check the temperature and adjust 

until you achieve the required 

temperature.
4. Replace the handle ensuring  it is in 

the same position as when removed.
5. To finish, tighten the grub screw 

and push-fit the cover cap into 

position.

Hotter

Cooler

Need help?

 Give us a call on

 0330 026 6273

 and speak to one of our trained advisors.  

Maintenance

16

Содержание H64DMT2

Страница 1: ...Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user Installation Instructions and User Guide Single Sequential D08...

Страница 2: ...ve been created to give you all of the information you need and if you need any further help please do not hesitate to give us a call on 0330 026 6273 Contents Important Safety Information 3 Specifica...

Страница 3: ...e maintenance Before installing this product the water supply must be thoroughly flushed in order to remove any swarf solder etc Full access must be made available for future maintenance servicing pur...

Страница 4: ...er will work adequately however the TMV3 scheme may not apply Supply requirements Minimum cold water supply temperature 5 C Maximum cold water supply temperature 25 C Maximum hot water supply temperat...

Страница 5: ...disassemble the mixer valve or reset the mixed water temperature Easy Clean Filters This TMV has easy clean filters which once removed isolate the water supply to the mixer body TMV3 Approved This TMV...

Страница 6: ...connecting the mixer tap Debris will reduce the performance and life of the mixer This mixer tap must be installed in compliance with current water regulations If you have any doubts about the water r...

Страница 7: ...ply Pumped System with Essex flange cold mains supply cold mains supply 2m min Key 2m min 50mm If less than 1m see note Isolating Valve Reducing Valve Mixer Tap Pump Essex Flange Need help Give us a c...

Страница 8: ...ackflow prevention device immediately upstream of the inlet b so that it draws water by gravity only from a cistern or cylinder having a permanently open vent pipe and the distributing pipe supplies n...

Страница 9: ...ns and user preference To Fit the Flow Straightener Insert the chosen flow straightener into the casing ensuring the sealing washer is placed on top of the flow straightener Using a suitable span ner...

Страница 10: ...backnuts fully using a suitable spanner 3 Connect Pipework Push the nuts and olives onto the pipework Push the pipework into the connections ensuring the olives are against the connections and tighte...

Страница 11: ...work Push the nuts and olives onto the pipework Push the pipework into the connections ensuring the olives are against the connections and tighten the compression nuts to create a water tight seal 4 T...

Страница 12: ...neutral liquid soap and polished with a soft cloth Any residues from soap toothpaste shampoos and shower gels can cause blemishes if not rinsed off straight after use Household bleaches and cleaners c...

Страница 13: ...are available if required in order to minimise down time for the mixer during this process We recommend that the valve should be thermally disinfected using the integral flushing process following an...

Страница 14: ...y result in seizing of the filters 1 Remove the control handle lever remove the cap and undo the screw and remove the lever 2 Unscrew the cartridge nut anti clockwise using a 30mm socket and remove th...

Страница 15: ...pliers pull the internal tube from the inlets 4 Replace Internal Tube Replace the internal tube using a new spare part supplied from Bristan Note Internal tube with yellow flow regulator must be fitte...

Страница 16: ...ot correct re calibrate the mixer tap 1 Turn the flow of water on 2 Remove the temperature control lever Remove the cap undo the grub screw and carefully remove the lever handle 3 Insert a 2 5mm hexag...

Страница 17: ...sing a 2 5mm hexagonal key open the hot water bypass flushing screw turning anti clockwise until it stops completely 4 Turn the flow of water on by turning the flow handle to the On position 5 Hot wat...

Страница 18: ...ausing pressure changes or instantaneous boiler temperature changes Do not use other water outlets when using the mixer Make sure the maintained inlet pressures are nominally balanced and sufficient R...

Страница 19: ...tantaneous water heater not igniting because water flow rate is too low Increase water flow rate through the system Refer to the Maintenance section to clean the cartridge Contact the boiler manufactu...

Страница 20: ...w bristan com register For any other queries please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice For full guarantee terms...

Отзывы: