Faultfinder

Installation

A competent person must always carry out the installation of this product in
accordance with these instructions. The installation must comply with the
current local water company regulations.
The following points should always be considered when carrying out an
installation

1) Care must be taken to prevent any risk of injury or damage to persons or

property.

2) The product has integral isolation for servicing the unit, further isolation

could be included if considered necessary.

3) To eliminate pipe debris entering the valve the system must always be

thoroughly cleaned and flushed particularly if it is new, or extensive
modification has taken place. The product must never be used without
the in line filters fitted; failure to fit the filters may invalidate the
guarantee.

4) The fitting is supplied with a single check valve in each inlet; it should

be fitted so that the relevant air gap specified in the water regulations is
achieved above the spillover level of the basin or trough.

5) The surface to which the unit is to be fixed needs two holes minimum

23mm diameter maximum 30mm diameter at 150mm to 200mm centres
(the tails are eccentric giving variable centres)

6) If fitted in a health care environment the relevant Health Technical

Memorandum must be consulted to ensure correct positioning of the
outlet in relation to the basin or trough.

7) The unit is supplied suitably configured for fitting onto a high pressure

system if a low pressure system is to be used the flow limiters (item 16
and 17) must be removed see servicing for method.

8) When viewed from the front and the unit is connected to the supplies the

Hot supply must be connected to the left hand inlet and the cold to the
right hand inlet.

Inlets

15mm Compression or ½” BSP
Male Iron

Outlet

24mm Flow Straightener

Minimum pressure drop through fitting for correct
mixing

0.1 bar

Maximum Pressure Drop Through Fitting for Correct
Mixing

5bar

Maximum static pressure to be applied to fitting

10bar

Mixed water temperature variation with nominal
variations of supply parameters

± 2ºC

Factory set maximum mixed water temperature

43ºC

Maximum hot supply temperature

80ºC

Maximum pressure loss ratio without flow limiters

5:1

Fault

Cause

Repair

No or reduced flow and/or
fluctuating temperature

One or both isolating valves not
fully open

Flow limiters incorrectly fitted

Inlet pressures below specified
values

Supply pipes blocked

Waterways in tap blocked

Supply pressures unequal

Open both valves fully

Check information and refit
correctly

Alter system to increase supply
pressures

Rectify system fault

Clear debris or call service
department

Check maximum pressure
differential, and check if flow
limiters correctly fitted

Maximum outlet temperature
too hot

Maximum mixed water
temperature incorrectly set

Reset temperature see
calibration section

Maximum outlet temperature
too cold or runs cold after a
short time

Maximum mixed water
temperature incorrectly set

Hot water temperature too low

Reset temperature see
calibration section

Increase water temperature by
adjusting storage temperature or
power input to the system

Mixed water flow too high

Flow limiters incorrectly fitted

See section on flow limiters

Only hot or cold water at outlet

Maximum mixed water
temperature incorrectly set

Inlet supplies reversed

Reset temperature see
calibration section

Re pipe supplies

Tap will not shut off or dripping

Seal damaged or worn

Scale build up in body

Inlet pressure above maximum
static pressure rating

Renew seals from spare parts kit

Service and descale fitting

Reduce pressure possibly by
fitting reducing valve

No thermostatic fail safe

Inlet temperatures outside
specification

Debris trapped in mechanism or
mechanism jammed

Inlet supplies reversed

Reset boiler or recirculation
temperatures

Strip and clean unit or call the
service dept

. Re pipe supplies