L
N
Rear bottom left
cable entry
Top left cable entry
Rear bottom
right cable entry
Note:
Depending on cable size and entry
point used it may be necessary to strip
back outer cable sheath sufficiently to
allow cables to be directed to the terminal
connection block within the unit.
Bottom left
cable entry
*
Bottom right
cable entry
*
*
Note:
When feeding cable
through bottom entry
points remove highlighted
grey tab on pipe/blanking
cover if using 6mm cable.
For 10mm cable remove
the pipe/blanking cover
entirely.
Pipe
cover
Blanking
cover
Warning: This appliance and all connecting metal pipe work
must be earthed.
•
Ensure that an earth continuity conductor is securely and permanently connected to all exposed metal
parts of other services and appliances within the room where the shower is installed.
All cables
must
conform to the relevant tables within the current I.E.E Wiring Regulations (BS 7671). The
electrical supply cable must be either recessed or in a conduit/trunking as detailed in the current I.E.E
Wiring Regulations (BS 7671). Refer to pages 7 and 8.
Electrical Connection Entry Point Options
Select the cable inlet option most suited to your situation.
L
N
L
N
L
N
L
N
14
Need help?
Give us a call on
0330 026 6273
and speak to one of our trained advisors.
Electrical Connections