Specifications
Specifications
Inlet connections:
15mm compression, with approximately 150mm between centres.
Operating pressure range:
Min. 0.1 bar - Max. 5.0 bar - Maximum recommended
imbalance between hot and cold supply should not exceed a ratio of 5:1.
Maximum outlet temp:
Factory pre-set to 41°C (can be re-set to suit site conditions).
Supply requirements:
Minimum cold water supply temperature: 5°C.
Maximum cold water supply temperature: 25°C.
Maximum hot water supply temperature: 80°C.
(a maximum hot water supply temperature of 60 - 65°C is recommended for
ablutionary purposes)
Note:
The inlet hot water temperature must be at least 10°C above the required blend
temperature (eg. shower temperature 43°C: minimum hot supply 53°C).
Minimum dynamic pressure: 0.1 bar.
Maximum dynamic pressure: 5.0 bar.
Maximum static pressure: 10.0 bar.