Electrical Requirements
Important:
You must switch off the power at the consumer unit,
isolate the electrical circuit and verify the earth before
making any electrical connections.
The Mixing Valve must only be connected to a 230-240V AC supply. This product
must be connected to a fused spur with double-pole isolation and a 3A fuse.
It is recommended that a residual current device (RCD) formerly known as an earth
leakage circuit breaker (ELCB) with a tripping current of 30mA, incorporated in the
circuit. This may be part of the existing consumer unit or a seprate unit.
For close circuit protection
DO NOT
use a rewireable fuse. Instead use a suitably
rated miniature circuit breaker (MCB) or Cartridge Fuse.
Do not turn on the electrical supply until the plumbing has been completed and the
Mixing Valve cover re-fitted (if removed).
Installation
Fixing the Mixing Valve to the
floor/wall
Please refer to ‘Positioning the Mixing
Valve’ on before starting any installation.
The Mixing Valve needs to be installed
on either a flat floor or a wall surface.
Position the Mixing Valve on the floor or
wall surface and mark all 4 fixing points.
Fixing Points
IMPORTANT
Prior to drilling
check ther
e
are no hidden
electrical cables
or water supply
pipes