Maintenance

General Cleaning 

Your fitting has a high quality finish and 

should be treated with care to preserve 

the visible surfaces. All surfaces will 

wear if not cleaned correctly, the only safe 

way to clean your mixer is to wipe with a 

soft damp cloth. Stains can be removed 

using washing up liquid. All bath cleaning 

powders and liquids will damage the 

surface of your fitting, even the non-

scratch cleaners.

 

Note:

 Never use abrasive detergents or 

disinfectants or those containing alcohol, 

hydrochloric acid or phosphoric acid.

Bristan recommend E-cloth for 

cleaning all of our bathroom 

& kitchen products. Using 

just water, E-cloth gives a 

smear free, deep clean by breaking up 

and holding dirt, which normal cloths 

leave behind. Order through your Bristan 

stockist (order code: ECLOTH).

 

Cartridge Maintenance 

We advise that the shower valve is 

regularly serviced in hard water areas to 

maintain the flow of water (see Map of 

Hard Water Regions in the UK on page 25).

Isolate both hot and cold water supplies to 

the shower valve by either:

• Turning the water supply off at the 

mains stopcock or

• Turning off the isolation valves to the 

shower valve

1. 

Remove the temperature control cover, 

undo the screw, remove the handle and 

plastic stop.

Important:

 Take note of the positions of 

the plastic stop and handle - they must be 

refitted in the same positions.

2. 

Unscrew the cartridge anti-clockwise 

and remove from the valve body.

3. 

Place the cartridge in a bowl and 

carefully add hot water (just off the boil) 

and vinegar to de-scale the cartridge. 

Leave in the solution until the water has 

cooled and rinse with clean water.

4. 

Grease the seals with a silicon grease 

supplied by Bristan (part number: SP-

495-0002) and carefully refit.

5. 

Reset the maximum temperature and 

refit the handle and cover. 

Note:

 For step by step video guidance on 

how to service this shower valve please 

visit

 http://

www.bristan.com/howto

Cleaning the Showerhead 

Your Bristan showerhead has rub-clean 

nozzles for easy cleaning. Simply rub 

your fingers across the rubber spray jets 

regularly and before you  turn the shower 

on to remove any scale or debris. 

The hardness of the water in your area 

will determine how often you should clean 

your showerhead. Build up of scale in 

particularly hard water areas combined 

with constant use means you may need 

to clean your showerhead once a week. 

To ensure continued performance of 

your shower the showerhead needs to be 

regularly descaled.

Содержание AR2 SHXMTFF

Страница 1: ...nce Installer when you have read these instructions please ensure you leave them with the user Installation Instructions and User Guide Artisan Thermostatic Surface Mounted Bar Shower Valves Models co...

Страница 2: ...by Bristan are safe providing they are installed correctly and receive regular maintenance in accordance with these instructions Important Safety Information 3 General Information 4 Product Features 5...

Страница 3: ...itions Do not crush or kink the shower hose this could damage the hose and cause leaks Remove all packaging and check the contents for damage before starting installation Before starting any installat...

Страница 4: ...ture of 60 C is considered sufficient to meet all normal requirements and will minimise the build up of lime scale in hard water areas see Map of Hard Water Regions in the UK on page 25 If the fitting...

Страница 5: ...low settings Off Medium eco and High Controls the amount or flow of water from the showerhead When in medium eco setting the button must be pressed to increase the water flow 2 Temperature Control Adj...

Страница 6: ...old cold mains supply cold mains supply Important If you install this shower valve with a gravity fed system there must be a minimum head vertical distance from the underside of the cold water storage...

Страница 7: ...ntaneous Water Heater Pumped System cold mains supply cold mains supply cold mains supply Pumped System with Essex flange cold mains supply 1m min Key 1m min 50mm If less than 1m see note Isolating Va...

Страница 8: ...hbasins 38 C for bidets The mixed water temperatures must never exceed 46 C The maximum mixed water temperature can be 2 C above the recommended maximum set outlet temperatures Note 46 C is the maximu...

Страница 9: ...hot water supply to the shower valve during winter months in the UK when the mains cold water supply is at its coldest In the event that this shower valve is not installed with an instantaneous water...

Страница 10: ...approved double check valve assembly or some other no less effective backflow prevention device immediately upstream of the inlet b so that it draws water by gravity only from a cistern or cylinder ha...

Страница 11: ...The Riser rail wall brackets can be positioned up or down the riser rail as required This allows any existing holes to be reused or covered by the wall brackets The brackets can also be adjusted to si...

Страница 12: ...site conditions Supply requirements Minimum cold water supply temperature 5 C Maximum cold water supply temperature 25 C Maximum hot water supply temperature 80 C a maximum hot water supply temperatu...

Страница 13: ...13 Pack Contents AR2 SHXVOFF C 1 Shower valve 2 Wall plates x2 3 Olives x2 4 Fixing bridges x2 5 Covers x2 6 Filter washers x2 7 Wall plate fixings x4 4 8 Plastic inserts x2 1 2 3 4 5 6 7 8...

Страница 14: ...ates x2 3 Olives x2 4 Fixing bridges x2 5 Covers x2 6 Filter washers x2 7 Wall plate fixings x4 4 8 Plastic inserts x2 9 Showerhead single function 10 Rubber washers x2 11 Shower hose 12 Riser rail 13...

Страница 15: ...plates x2 3 Olives x2 4 Fixing bridges x2 5 Covers x2 6 Filter washers x2 7 Wall plate fixings x4 4 8 Plastic inserts x2 9 Showerhead 3 function 10 Rubber washers x2 11 Shower hose 12 Riser rail 13 R...

Страница 16: ...e check for any hidden pipes and cables before drilling holes in the wall Drill suitable holes and insert the wall plugs Securely attach the wall plates 2 to the wall using the screws 7 3 Attach olive...

Страница 17: ...ilter washers 6 into the shower valve fixing nuts Position the shower valve 1 against the fixing bridges and carefully tighten the shower valve fixing nuts onto the fixing bridges Do not overtighten N...

Страница 18: ...pipes and cables before drilling holes in the wall Drill suitable holes and insert the wall plugs Securely attach the wall brackets to the wall using the screws 13 Tips A piece of insulation or maski...

Страница 19: ...et Push the slider down onto the riser ensuring it is the correct way up as shown Then push the riser rail up through the top wall bracket 5 Tighten rail clamps Centre the riser rail within the wall b...

Страница 20: ...he shower hose ribbed nut end onto the mixer ensuring that the rubber washer is fitted 8 Connect shower hose to showerhead Screw the shower hose conical end onto the showerhead ensuring that the rubbe...

Страница 21: ...ress the button and turn the control when a water temperature over 38 is required Riser rail Turning the slider handle will allow the slider to be raised and lowered and the angle of the showerhead to...

Страница 22: ...er supply to the TMV wait for five seconds if water is still flowing check that the temperature is below 46 C If there is no significant change to the set outlet temperature 2 C or less change from th...

Страница 23: ...lves to the shower valve 1 Remove the temperature control cover undo the screw remove the handle and plastic stop Important Take note of the positions of the plastic stop and handle they must be refit...

Страница 24: ...er with a thermometer If the temperature is not correct re calibrate the shower valve 1 Remove the temperature control cover undo the screw and carefully remove the handle but do not remove the plasti...

Страница 25: ...quivalent LU LL LL CH CW SY SA LD CF HR OX BS GL SN SP BA TA EX PL TQ TR DT BH SO PO PO GU BN RH RG SL HP AL KT SG MK NN PE CB LE WR TF WV WS ST SK DE B CV DY HG LN S DN YO HG NE CA LA DL DH PR L WN B...

Страница 26: ...tantaneous boiler temperature changes Do not use other water outlets when using the shower Make sure the maintained inlet pressures are nominally balanced and sufficient Refer to Installation Requirem...

Страница 27: ...set Hot water temperature is less than 10 C above the required blend temperature Adjust hot water temperature or wait for water to reheat if stored system is used Instantaneous water heater not igniti...

Страница 28: ...ts with a manufacturing fault A deferred payment will be necessary in order to secure any visits by our engineers which will be charged if the problem is found not to be a manufacturing fault If the f...

Страница 29: ...e fully qualified to advise on correct installation procedures and will be able to diagnose whether the fault will require a replacement part or a visit from a Bristan engineer If required a service c...

Страница 30: ...30 Notes Please use this space to add any notes you or your installer may have regarding the plumbing system installation of this product...

Страница 31: ...31 Notes...

Страница 32: ...32 Bristan Group Ltd Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web www bristan com Email enquire bristan com A Masco Company Part Number FI AR2 SHX Issue D1...

Отзывы: