SREH Silicone Rubber Enclosure Heaters 

CONNECTING HEATER TO AC POWER 

 
 



The heater is designed to operate at a specific voltage:

 Refer to the lead 

wire label or stamp located on the heater for rated voltage and wattage. 
Failure to operate the heater at its rated voltage could cause damage to the 
heater, surface being heated, or contents. 



All electrical connections must be made by qualified personnel and in 
accordance with all local codes and regulations. 

Two wires (same color) 

should be connected to the power source directly, through a junction box, or 
to a connector that is mated to a receptacle connected to the power source. 
BriskHeat

®

 SREH Silicone Rubber Enclosure Heaters are non-polarized, 

allowing either wire to be connected to the neutral or hot. 



Properly sized circuit breakers must be used.

 The end-user is 

responsible for providing suitable electrical protection device. It is highly 
recommended that a ground fault circuit breaker be used. 

© BriskHeat

®

 Corporation.  All rights reserved.

 

 

SREH Silicone Rubber Enclosure Heaters 

TROUBLESHOOTING GUIDE 

Please read this guide prior to contacting BriskHeat

®

. This guide is designed to 

answer the most commonly asked questions. If you are unable to identify the 
problem or need additional assistance, please contact your local distributor/ 
representative or us at 

1-800-848-7673

614-294-3376

, or 

[email protected]

PROBLEM 

SOLUTION(S) 

Heater does not warm up  Verify heater is connected to proper voltage. 

Check to see if there is a resistance reading (not 
an open circuit) in heater using an ohm meter. 

Circuit breaker is tripping  Validate that the circuit breaker is capable of 

handling the amp requirement of heater. The 
identification label located on the power cord 
displays the heater’s amperage requirement. 

Examine heater and cord for any damage. 

Check to see if there is a resistance reading 
between power leads and the ground lead. 