OPERATION INSTRUCTIONS

Read and understand this entire 
manual before operating this gas 
cylinder warmer.

VOLTAGE:
120VAC; 240VAC

5

STEP 1

Remove heater from box.  Make visual 
inspection of heater.  Do not use if 
torn or damaged.

STEP 2

Gas cylinder should be placed on 
a clean, dry surface.  

2A.)

 Open 

VELCRO

®

 closure on heater and 

position around cylinder with the 
power lead exit on the bottom of 
the heater.  

2B.) 

Heater should be 

positioned on cylinder such that it is 
covering the cylinder from the 

fl

 oor 

to the top of the cylinder. 

2C.) 

Attach 

VELCRO

®

 closure so heater is tight 

against the cylinder with no sagging 
or bundling. Cover any valves on top 
of cylinder with optional insulating 
blanket. (sold separately)

STEP 3 

(see page 3 for electrical 

compliance)

Terminate power cord to appropriate 
electrical power supply. The power 
cord consists of three color-coded 
conductors, black, white, and non-
insulated. The black wire should be 
connected to incoming hot line.  The 
white wire should be connected 
to the neutral (for 120V) or power 
return (for 240V).  The non-insulated 
wire should be connected to earth 
ground.  The power connections must 
be adequately rated to electrically 
support the voltage and amperage 
of the heater.  Follow all local 
electrical codes for proper electrical 
connections. 

2A.) 

2B.) 

2C.) 

SPECIFICATIONS

4

Operating conditions:

Operating Ambient Temperature Range: 

 

30

o

F-95

o

F (-1

o

C – 35

o

C)

Temperature Range maintained on Bottom of Cylinder: 

90

o

F-130

o

F (32

o

C – 54

o

C)

Temperature Range maintained on Top of Cylinder: 

80

o

F-120

o

F (27

o

C – 49

o

C)

Self-Regulating Grounded Heating Element

120 or 240 Volts Models

Up to 150 Watts

Water Resistance

Oil and Some Chemical Resistance

Both Indoor and Outdoor Use

GCW Series: Ordinary Locations
HCW Series: CSA Class I Division I Groups C & D

2"

(51mm)

1/2"

(13mm) ON

TOP

»

3

1/2"

(88mm)

Part Drawing

Содержание GCW Series

Страница 1: ...nd understand this material before operating or servicing these gas cylinder warmers Failure to understand how to safely operate these heaters could result in an accident causing serious injury or death These heaters should only be operated by qualified personnel ...

Страница 2: ...inder Warmer is installed Explosion hazard Do not disconnect equipment unless power has been switched off or the area is known to be non hazardous The end user is responsible for providing a suitable disconnecting device The end user is responsible for providing suitable over protection device It is highly recommended that a ground fault circuit breaker be used TABLE OF CONTENTS INTRODUCTION The s...

Страница 3: ...ctrical compliance Terminate power cord to appropriate electrical power supply The power cord consists of three color coded conductors black white and non insulated The black wire should be connected to incoming hot line The white wire should be connected to the neutral for 120V or power return for 240V The non insulated wire should be connected to earth ground The power connections must be adequa...

Страница 4: ...Heat s obligation under this warranty shall be conditioned upon BriskHeat s receiving written notice of any defect within fifteen 15 days after its discovery and at BriskHeat s option return of such equipment or parts prepaid to its factory at 1055 Gibbard Ave Columbus Ohio 43201 Disclaimer BRISKHEAT MAKES NO WARRANTY WHATSOEVER EXPRESS OR IMPLIED EXCEPT AS IS EXPRESSLY SET FORTH ABOVE NO AGENT EM...

Страница 5: ...BriskHeat Corporation 1055 Gibbard Ave Columbus OH 43201 Toll Free 800 848 7673 Phone 614 294 3376 Fax 614 294 3807 Email bhtsales1 briskheat com Web site www briskheat com PN 11612 Rev D ...

Отзывы: