5  Installation and Connection 

5.1  Mechanical installation 

During  any  assembly  or  disassembly  process  the 
pumps  must  be  secured  against  tipping  trough 
ropes for example at all times.

 

Pumps must be mounted securely. Piping, tank and 
pumps must be mounted without any tension. 
The  inlet  is  at  the  bottom  of  the  immersed  pump 
body.  The  distance  between  the  inlet  and  the  tank 
bottom  must  be  so  large  that  the  inlet  can  not  be 
blocked by deposits during longer shutdowns. 
To  obtain  the  full  flow  rate  it  is  recommended  to 
choose for the pipework the nominal bore diameter 
of  the  pumps  cross  section  for  connection.  There-
fore pipe bends should be used, not pipe angles! 
The  pipework  must  be  qualified  for  occuring  hy-
draulic pressure. 

 

 ATTENTION  

Maximum  tightening  torque  for  piping  connec-
tions is 150 Nm!

 

When  installed  the  space  around  the  pump 
must  be  large  enough  to  provide  sufficient 
cooling of the motor. 

Do not prop up the pressure line via the joining 
socket. 

 

 

The  pump  must  be  mounted  in  that  way  that 
rotating  parts  under  the  cover  of  the  coolant 
tank can not be touched!

 

5.2  Electric wiring 

 

All  service  work  must  be  carried  out  by  quali-
fied  service  personnel.    Pump  must  be  discon-
nected  from  the  power  source  and  all  rotating 
parts  must  stand  still.    Reassure  that  pump  is 
disconnected from power source and cannot be 
switched  on.    Verify  that  there  is  no  voltage  at 
the terminal board!  

According  to  the  European  Standard  EN809  a 
motor  overload  must  be  installed  and  properly  set 
to  the  full  load  amps  stated  on  the  pump  name 
plate. 

It  is  the  responsibility  of  the  machine  operator  to 
decide  whether  or  not  an  additional  emergency 
switch must be installed. 

5.2.1 

Circuit 

 

Tension  voltage  and  frequency  must  correspond 
with the shown specification on the nameplate

.

 

The  pump  must  be  wired  so  that  a  solid  longterm 
electrical  connection  is  ensured.  Establish  a  solid 
ground connection. 

The electrical wiring must be performed accord-
ing  to  the  wiring  diagram  shown  inside  the 
terminal  box  cover.  (Please  see  above  sample 
wiring diagrams) 

Wiring diagram e.g. 

 

There  may  be  no  foreign  objects  such  as  dirt, 
particles or humidity inside the terminal board. 

Mount  terminal  board  cover  to  motor  tight  against 
dust  and  humidity  and  close  up  all  unused  wiring 
ports. 
 

 ATTENTION  

When Variable Frequency Drives are used interfer-
ing signals might occur. 
Non-sinus shaped supply voltage from a variable 
frequency drive might result in elevated motor 
temperatures. 

 

 

   

 

 

Star connection  

3 x 400 V, 50 Hz 

resp. 380-415 V, 50 Hz 

 

 

 

 

 

Delta connection  

3 x 230 V, 50 Hz 

resp. 220-240 V, 50 Hz

 

 

Содержание SGL331 Series

Страница 1: ...2019 Page 1 of 10 BRINKMANN Immersion Pumps SGL331 503 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sales...

Страница 2: ...l description of the pump Pumps of this type are one or multi stage rotary pumps where the impellers are fixed on the driving shaft extension The pump shaft and motor shaft are interconnected by means...

Страница 3: ...SGL333 240 320 390 470 560 670 870 1020 3 2 380 439 240 320 390 470 560 670 870 1020 40 41 42 43 45 47 53 55 2 2 2 55 SGL501 150 230 300 380 470 580 780 930 1 0 420 361 150 230 300 380 470 580 780 930...

Страница 4: ...ards they must be guarded against acci dental contact Guards for moving parts e g coupling must not be removed from the machine while in opera tion Any leakage of hazardous e g explosive toxic hot flu...

Страница 5: ...onnel Pump must be discon nected from the power source and all rotating parts must stand still Reassure that pump is disconnected from power source and cannot be switched on Verify that there is no vo...

Страница 6: ...ere is no voltage at the terminal board Open terminal box and disconnect the power leads Empty out the pump 7 Operation Liquid level According to the drawing shown below the maxi mum liquid level must...

Страница 7: ...above Clean pump mechanism repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate r...

Страница 8: ...472 22 Retaining ring DIN 471 23 Compensation disk up 1 3 kW 24 Shaft seal 25 O ring up 1 3 kW 50 Pump body 51 Shaft with rotor 52 Intake cover 53 Pump plate up SGL332 502 55 Impeller 57 Suction scre...

Страница 9: ...ust not be lubricated or oiled Set the motor down on the fan cover Position the shaft clamp 1 use a new shaft clamp in the centre of the cranked clamping di ameter 2 of the insert shaft Insert the mot...

Страница 10: ...linie 2006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines 2006 42 EC...

Отзывы: