EN
ELUM Sp. z o.o.
1A Wilanowska Str., 05-520 Konstancin-Jeziorna, Poland
www.elum24.pl
Floodlights
INSTALLATION AND OPERATING MANUAL
ADVIVE PLUS – LED floodlights
ADVIVE PLUS
ADVIVE PLUS, 50W
ADVIVE PLUS, 30W
ADVIVE PLUS, 100W
ADVIVE PLUS, 70W
ADVIVE PLUS, 150W
220 ÷ 240VAC
50/60Hz
IP 65
4000K
25000h
120
+45
-25
C
o
1m
CRI
>
80
30W, 50W, 70W
100W, 150W
Model
A [mm] B [mm] C [mm] D [mm] E [mm]
ADVIVE PLUS, 30W
150
105
25
75
160
ADVIVE PLUS, 50W
203
160
25
120
160
ADVIVE PLUS, 70W/100W
290
206
32
140
160
ADVIVE PLUS, 150W
330
250
35
160
160
DIMENSIONS (mm)
A
B
C
D
E
Table 1.
Model
ADVIVE PLUS
Power of the luminaire
30W
50W
70W
100W
150W
Supply voltage
220 ÷ 240V AC
Frequency
50/60Hz
Power factor (cos φ)
0,9
Beam angle
120°
Protection rate
IP 65
Protection class
I
Type of light source
LEDs SMD type
Light colour
neutral white
Correlated colour temperature
4000K
Colour rendering index (CRI)
> 80
LEDs lifespan*
25 000 hours
Luminous flux of the luminaire**
2700 lm
4400 lm
5600 lm
8600 lm
12000 lm
Ambient temperature
-25°C ÷ +45C
Weight
0,35kg
0,80kg
1,35kg
1,50kg
2,20kg
*
provided parameter is based on LEDs manufacturer’s data / **
parameter is provided with ± 10% tolerance margin
TECHNICAL DATA
INSTALLATION
Fig.1.
Fig.2.
CHARACTERISTIC
ADVIVE PLUS floodlights are energy-saving and universal LED luminaires for applications both
indoors and outdoors, due to the high IP 65 protection rating.
They are perfect for illumination of various objects and surfaces like: buildings elevations,
yards, entrances, gates, gardens, architectural facilities, parking lots, boards, billboards, store
windows, interior spaces with conditions of increased humidity and pollination level.
The housings of ADVIVE PLUS luminaires are made of ribbed aluminum casting that provides
efficient heat dispersion. The tempered glass shield provides high protection rating as well
as effective protection of LEDs against mechanical impact.
Due to metal movable mounting bracket those luminaires are adapted for installation with
various inclination angles. Minimum distance from the illuminated object: 1m between the
floodlight and the object or illuminated surface.
LED panel with LEDs SMD type is used as the light source in ADVIVE PLUS floodlights, it allows
significant energy saving comparing to traditional luminaires and keeps the same luminous
parameters. The light sources of the luminaires are not replaceable, once the light source is
used up full luminaire should be replaced.
Light colour: neutral white (4000K).
The luminaires are equipped with power cable that is lead out of the luminaire through tight
gland. The lenght of power cable is shown in Table 1. The luminaires are power supplied
directly from mains ~230V. Terminal block / hermetic cable connector for current ~230V are
not included in the set.
1. Mark and drill properly spaced installation holes on the mounting surface.
Screw the floodlight to the mounting surface [Fig.1.].
3. Stabilize the floodlight in chosen position.
2. Connect the power cable to terminal block or hermetic connector [Fig. 2.], accordingly:
- phase cable (brown) to the slot marked “L”,
- neutral cable (blue) to the slot marked „N”,
- safety cable (yellow-green) to the slot marked .
Recommended hermetic connectors ELGO brand ZH1-3P25, ZH2-3P25 and ZH3-3P25.
The terminal block and hermetic connector are not included in the set with the luminaire.
CAUTION!
1. Installation of the luminaire should be done by the certified and experienced electrician.
Before
starting the installation you must absolutely turn off the main power supply, where the
luminaire should be connected to, to avoid accidental voltage connection! Electrical cables must
be connected according to the instruction and regulations in force.
Performing any operations
inside the luminaire with the power supply switched on may result in an electric shock!
2. Do not look directly at LED light beam.
3. Product can only be supplied by rated voltage or voltage within the range provided.
4. It’s forbidden to use the product with damaged protective cover.
5. We take no responsibility for any damages due to improper installation.
6. We reserve the right to apply changes in the construction of the product.
7. The information included in this document may undergo changes without warning.Possible
changes will be taken into consideration while working with other issues of the instructions
for use or complementary documents.
8. We take no responsibility for faults resulting from non-compliance with the above instructions.
According to article 568 pt 1 of the Polish Civil Code, the right resulting from a warranty for
physical defects are extinct after the lapse of 2 (two) years after delivery of the luminaire
to the Buyer.
9. To keep the optimal technical parameters of the luminaire the periodical maintenance should be
carried out. Before cleaning the product, disconnect it from power supply. Ignoring this warning
can cause danger of electric shock. Clean only with soft and dry cloths. Do not use corrosives
chemicals and solvents. Do not use stream of water under pressure.
This symbol stands for selective collecting of the electrical and electronic equipment, therefore,
this product cannot be treated as other household’s waste. It has to be left at a special
used-equipment collection point. The appropriate dealing with the collection of used electrical
and electronic equipment is crucial, especially if the equipment includes dangerous
components which have a negative influence on the environment
and on the health of people.