13
The mantle fixing bracket is screwed to the top
of the box in its correct position and does not
need to be removed.
Remove the four screws that secure the burner
to the box, two at the base of the front leg and
two at the top of the rear sloping plate. Separate
the burner from the box (see diagram C.1).
Remove the two countersunk screws securing
the raised hearth to the shelf, carefully remove
the raised hearth and place to one side (see
diagram C.2).
Level the floor beneath the hearth. Fit the
hearth ensuring it is central, level left to right
and perpendicular to the wall.
Prepare the gas supply noting the entry point in
the rear of the box. Slacken the screws in the
gas inlet closure plate and remove. Offer the
box into the fireplace opening, mark the
positions of the four fixing holes in the outer
frame. Remove the box, drill and plug the fixing
holes using the plugs provided (see diagram
C.1).
Partially peel the protective plastic coating away
from the metal box anywhere it may become
trapped.
Apply a thin bead of silicon sealant around the
rear edge of the box flange. Insert the gas pipe
through the pipe entry opening and insert the
box fully into the fireplace opening. Secure to
INSTALLATION - SLAB 30, SLAB 22
C
SLAB 30
SLAB 22
Raised Hearth
2
Raised Hearth
Fixing Points
Mantle Fixing
Holes
1
Gas Inlet
Fixing
Holes
Mantle Fixing Bracket
Burner Fixing Points