Duct Cover Installation 

 

6.  Use 6” round steel pipe for 30” and 36” models 

or  8”  round  steel  pipe  for  48”  models  (follow 
building  codes  in  your  area)  to  connect  the 
exhaust  on  the  hood  to  the  ductwork  above.  
Use duct tape to make all joints secure and air 
tight.  Refer Figure 5.   

7.  Use four 4mm x 8mm screws (included) to attach 

duct cover to hood. Refer to Figure 6. 

 
 
 

Install Accessories

 

 

8.  Attach oil tunnel.  Refer to Figure 7.  
9.  Refer to Figure 8.  

 Slide the baffle filter into 

the  hood.   

  Push  the  baffle  filter  upward.   

 

Slide  forward.   

  Pull  downward.   

  Fit  into 

place. 

10. Repeat  until  all  baffle  filters  and  spacers  are 

resting against oil tunnel.  Refer to Figure 8. 

 
 
 

Final Assembly 

 

11. Turn power ON in control panel.  Check all lights 

and fan operation. 

12. Make  sure  to  leave  this  manual  for  the 

homeowner. 

 
 
 
 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 

 

  Figure 7 

 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 8 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 

Содержание RAX95 SQB-1

Страница 1: ...Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom 30 36 Hood Recommended 27 to 30 48 Hood Recommended 30 to 36 A B D E D Height of Hood E Height of Duct Cover SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE ...

Страница 2: ...ay reduce the performance of the hood Temporarily wire the hood to test for proper operation before installing Important Peel protective film off the hood and the duct cover if any If necessary prepare back wall frame with cross framing lumber for secure installation Refer to Table 1 and measurements on Page 12 to decide the level of the lumber Figure 2 Loosen hood mounting brackets at the back of...

Страница 3: ...ower Supply SAFETY WARNING RISK OF ELECTRICAL SHOCK THIS RANGE HOOD MUST BE PROPERLY GROUNDED MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES BEFORE CONNECTING WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY 5 Connect the electrical wires Connect three wires b...

Страница 4: ...s included to attach duct cover to hood Refer to Figure 6 Install Accessories 8 Attach oil tunnel Refer to Figure 7 9 Refer to Figure 8 Slide the baffle filter into the hood Push the baffle filter upward Slide forward Pull downward Fit into place 10 Repeat until all baffle filters and spacers are resting against oil tunnel Refer to Figure 8 Final Assembly 11 Turn power ON in control panel Check al...

Отзывы: