Faults

Remark

Reason

Solution

IPM module output circuit temperature 
sensor failure

EE14

The sensor output is abnormal 

Check the instrument panel or replace

Protection against excessively high IPM 
module temperatures

EE15

Check the instrument panel or replace

Protection of PFC module

EE16

Check the instrument panel or replace

DC fan error

EE17

Check the instrument panel or replace

IPM module input circuit temperature sensor 
failure 

EE18

Check the instrument panel or replace

Protection against excessively high PFC 
module temperatures 

EE19

Check the instrument panel or replace

Electrical power failure

EE20

The supply voltage is too variable 

Check the instrument panel or replace

Software check error 

EE21

The compressor runs outside of preset steps 

Check the instrument panel or replace

Current detection circuit fault 

EE22

Abnormal amplification of the output voltage 

Check the instrument panel or replace

Compressor switch fault

EE23

Check the instrument panel or replace

Ambient temperature thermometer control 
unit failure 

EE24

Compressor phase error

EE25

1. Badly connected wiring,
2. Connection of one or two phases 

Monitor the controller

Defrosting symbol, heater check is lit

Defrosting of glass

8.2 Other Malfunctions and Solutions (No display on LED wire controller)

Malfunctions 

Observing

Reasons

Solution

Heat pump is 
not running

LED wire controller
no display.

No power supply

Check cable and circuit breaker if 
it is connected

LED wire controller.
displays the actual time. 

Heat pump under standby status

Startup heat pump to run.

LED wire controller
displays the actual
water temperature.

1. Water temperature is reaching 
to setting value, HP under con-
stant temperature status.
2. Heat pump just starts to run.
3. Under defrosting.

1. Verify water temperature 
setting.
2. Startup heat pump after a few 
minutes.
3. LED wire controller should 
display „Defrosting“.

Water temperature is cooling 
when HP runs under heating 
mode

LED wire controller displays 
actual water temperature and no 
error code displays.

1. Choose the wrong mode.
2. Figures show defects.
3. Controller defect.

1. Adjust the mode to proper 
running 
2. Replace the defect LED wire 
controller, and then check the 
status after changing the running 
mode, verifying the water inlet 
and outlet temperature.
3. Replace or repair the heat 
pump unit

Short running

LED displays actual water 
temperature, no error code 
displays.

1. Fan NO running.
2. Air ventilation is not enough.
3. Refrigerant is not enough.

1. Check the cable connections 
between the motor and fan, if 
necessary, it should be replaced.
2. Check the location of heat 
pump unit, and eliminate all ob-
stacles to make good air venti-
lation.
3 Replace or repair the heat pump 
unit.

water stains

Water stains on heat pump unit.

1. Concreting.
2. Water leakage.

1. No action.
2. Check the titanium heat 
exchanger carefully if it is any 
defect.

Too much ice on evaporator

Too much ice on evaporator.

1. Check the location of heat 
pump unit, and eliminate all ob-
stacles to make good air venti-
lation.
2. Replace or repair the heat 
pump unit.

Содержание XHPFD 100 E

Страница 1: ...INVERTER SWIMMING POOL HEAT PUMP USER MANUAL Illustrative photo i Read the instructions EN VERZE 8 6 2017 REVIZE 3 11 2017...

Страница 2: ...ol heat pump for your pool heating it will heat your pool water and keep the constant temperature when ambient temperature at 10 C to 35 C Regulation EU n 517 2014 of 16 04 14 on fluorinated greenhous...

Страница 3: ...ump during winter time or when the ambient temperature drops below 0 C or else the Titanium exchanger will be damaged because of being frozen in such case your warranty will be lost WARNING Please alw...

Страница 4: ...PH Std Current Input A 3 7 4 6 5 4 Maximum Current A 6 65 Minimum fuse A 18 18 18 Water in out connection mm 50 Fan quantity 1 Ventilation type Horizontal Compressor brand GMCC GMCC GMCC Compressor t...

Страница 5: ...nt Input A 7 2 9 11 9 Maximum Current A 11 31 25 32 Minimum fuse A 31 Water in out connection mm 50 Fan quantity 1 2 Ventilation type Horizont ln Compressor brand MITSUBISHI MITSUBISHI PANASONIC Compr...

Страница 6: ...s m3 h Voltage 380 V 50 Hz 3 PH 220 240 V 50 Hz 1 PH 380 V 50 Hz 3 PH Std Current Input A 5 1 14 9 6 4 Maximum Current A 15 40 18 Minimum fuse A Water in out connection mm 50 Fan quantity 2 Ventilatio...

Страница 7: ...7 2 Dimension XHPFD 100 E XHPFD 160 E...

Страница 8: ...ation please consult more instruction from technicians 6 When install a bypass it should be not exceed 30 of nominal flow rate 7 Must make Water level higher than the circulation pump location 8 Below...

Страница 9: ...lose the valve direct 2 Make sure that the pump and the water in pipe have been filled with water 3 Start the unit 16 The location of chemical s instruction to your system is also critical to the heat...

Страница 10: ...must be running to cause the water to circulate through the heat pump The heat pump will not start up if the water is not circulating After all connections have been made and checked carry out the fo...

Страница 11: ...will trigger this time delay and prevent the unit from restarting immediately Additional power interruptions during this delay period do not affect the 3 minute duration of the delay Condensation The...

Страница 12: ...6 2 button It will be under function only with other button 6 3 and button Clock unclock the display Hold and for 5 seconds to lock Unlock the display Water temperature setting Press or to set the wa...

Страница 13: ...time All error code 6 9 Press first then press to check adjust the User parameter from P1 to P7 Parameter code Condition Range Default Remarks P1 Working mode 0 1 1 1 Heating mode 0 cooling mode P2 Ti...

Страница 14: ...will flash When in Full output the lamp of Smart is lighting the lamp of Powerful will be flash 6 12 While you choose the Silent the heat pump will just operate in Medium output and Small output When...

Страница 15: ...3 Smart 15 Powerful setT 1 Powerful 7 2 The Cooling operation logic Working status Working mode Water in temperature Heat pump working level 1 Start up of heat pump Smart setT 1 Standby 2 setT 1 a se...

Страница 16: ...ve a specialised company change add refrigerant 2 Clean air heat exchanger 3 Replace the filter 4 Check and reconnect the electrical cables from the low pressure switch 5 Replace the low pressure swit...

Страница 17: ...circuit breaker if it is connected LED wire controller displays the actual time Heat pump under standby status Startup heat pump to run LED wire controller displays the actual water temperature 1 Wate...

Страница 18: ...Heating pipe temperature F Temperature of exhaust gases G Water out temperature H Water in temperature I Display Control J Water flow switch K Defrost switch L Low Pressure switch M High Pressure swit...

Страница 19: ...ct A disconnect means circuit breaker fused or un fused switch should be located within sight of and readily accessible from the unit This is common practice on commercial and residential heat pumps I...

Страница 20: ...20 11 Exploded view...

Страница 21: ...pipes 11 Lead 36 High pressure switch 12 Drainage stopper 37 Low pressure switch 1 13 PC inverter board 38 Low pressure switch 2 14 Regulator box cover 39 Filter 16 Regulator box 40 Temperature senso...

Страница 22: ......

Отзывы: