VIII. Maintenance

•  Check that the device water inlet is open. It is necessary to avoid low water and air 

fl

 ows into the device 

because they could worsen its performance and reliability. You have to clean the swimming pool 

fi

 lter 

regularly to avoid damage to the device as a result of a dirty or blocked 

fi

 lter.

•  The space around the device has to be dry, clean and well ventilated. Clean the side heat exchanger regularly 

in order to maintain good heat exchange performance and save energy.

•  The cooling system may only be serviced by certi

fi

 ed maintenance engineers.

IX. Troubleshooting

* Notes: 

One minute after its activation, the water pump starts measuring the temperature of the input and output water.

If the difference in temperatures is higher than 13ºC for 10 seconds, the electronics will stop the heat pump and the control unit 
will display fault PP6; after three minutes the heat pump will start again. If it stops three times in 30 minutes because of fault PP6,
the control unit will display fault EE5. It will be possible to start the heat pump again only after disconnecting and re-connecting the power supply. When 
the pump is not operating or the device is in heating mode, the system does not monitor abnormal temperature differences.

CONTROL UNIT

FAULT

CAUSE

SOLUTION

PP 1

Input water temperature
Sensor fault

Broken or short-circuited sensor

Check or replace the sensor

PP 2

Output water temperature
Sensor fault

Broken or short-circuited sensor

Check or replace the sensor

PP 3

Fault in coil sensor 1

Broken or short-circuited sensor

Check or replace the sensor

PP 4

Fault in coil sensor 2

Broken or short-circuited sensor

Check or replace the sensor

PP 5

Fault in surrounding temperature sensor

Broken or short-circuited sensor

Check or replace the sensor

PP 6

The temperature of input and output water 
is too high

Insuf

fi

 cient water output or too small

difference in water pressure

Check water output. Check that ventilation 
is not blocked.

PP 7

Protection against freezing for cooling

Insuf

fi

 cient water output

Check water output. Check that ventilation 
is not blocked.

EE 1

High pressure protection fault or system 1 
protection fault

Defective protection of system 1

Check each place of system 1 protection, 
remove the defect as stated in the fault table 
on the system protection card 

EE 2

High pressure protection fault or system 2 
protection fault

Defective protection of system 2

Check each place of system 2 protection, 
remove the defect as stated in the fault table 
on the system protection card

EE 3

Fault in the water pressure sensor

Water circuit without water or with too little 
water

Check water output. Make sure
the installation is not blocked.

Display empty

Poor-quality or missing phase
(for a three-phase device)

Poor-quality or missing phase

Check power cable wiring.

EE 5*

PP6 fault occurs three times in 30 minutes

Insuf

fi

 cient water output or too small

difference in water pressure

Check water output. Check that installation 
is not blocked.

EE 8

Fault in communication between the control 
unit and electronics

Fault in connection between the control unit 
connected with a cable and electronics

Check wiring.

Display empty

Defrosting underway

EN

Содержание THP 100

Страница 1: ...SWIMMING POOL HEAT PUMP THP 55 THP 100 THP 120 THP 170 INSTALLATION AND USER GUIDE EN i Read the instructions...

Страница 2: ...e control unit 9 VII Connection diagram 12 VIII Maintenance 13 IX Troubleshooting 13 Thank you for choosing our product and for your trust in our company To ensure that you can fully enjoy the product...

Страница 3: ...heat from the outside air and the coolant vaporises The warm gas in the pipeline passes through the COMPRESSOR which gathers the heat and increases the temperature to generate very hot gas which then...

Страница 4: ...240 1 50 Number of compressors 1 1 1 1 Compressor Scroll Number of ventilators 1 1 1 1 Input of ventilators W 25 50 50 50 Ventilator speed RPM 950 950 950 950 Noise dB A 53 55 57 59 Mains pipe mm 50 5...

Страница 5: ...as to be firm enough to ensure smooth operation of the device Make sure the device when installed is situated vertically without any inclination Do not install the device in places where there is cont...

Страница 6: ...expert technician If needed you should place barriers next to the device to keep children away from the running heat pump air inlet air inlet air outlet min 1000 mm min 1000 mm min 1000 mm from above...

Страница 7: ...7 back pressure valve chlorinator filter trap water pump back pressure valve 5 2 Installation diagram EN...

Страница 8: ...rdance with the wiring diagram An adequate earth connection is necessary to protect from electric shocks 6 1 Picture of the control unit A On off button B Mode selector automatic heating or cooling Th...

Страница 9: ...Setting the pipeline temperature for the start of defrosting 0 30 C 7 C 4 Setting the pipeline temperature for the end of defrosting 2 30 C 13 C 5 Maximum defrosting time 1 12 min 8 min 6 Number of sy...

Страница 10: ...the timer switch on time setting mode The hour and minute digits will start flashing b Again press button to activate clock setting The hour digits will start flashing to show that they can be change...

Страница 11: ...een yellow to electricity supply to water pump electricity supply control unit connected by cable surrounding pressure water pressure sensor low pressure sensor 1 exhaust temperature regulator 2 high...

Страница 12: ...Fault in coil sensor 1 Broken or short circuited sensor Check or replace the sensor PP 4 Fault in coil sensor 2 Broken or short circuited sensor Check or replace the sensor PP 5 Fault in surrounding...

Страница 13: ...guide Install recommended electric protective devices in accordance with local regulations The heat pump has to be earthed to protect you from electric shocks due to possible short circuits This guide...

Отзывы: