Brilix Hidrolife Скачать руководство пользователя страница 2

2

A

B

1

3

9

10

15

16

17

8

C

Acid dosing pump 

(optional - for models with PH control)

Acid injector  

(optional - for models with PH control)

Hydrochloric acid container  

(optional, for models with PH control,  

not supplied with unit)

A
B
C

Filtration pump timer
Silex / glass / diatom filter 
Recirculation pump

1
3

4

5

Electronic box
Electrolysis cell  

(always in vertical position) 

pH probe  

(optional - for models with pH control)

redoX probe   

(optional - for models with redoX control)

8

9

10

15
16
17

Other pool equipment
Module RF or RF/WIFI or WIFI
Free chlorine control

Product

Maximum 

consumption

Recommended 

protection

gr Cl

2

/h

SAL 8

80 W

10 A

8

SAL 16

120 W

10 A

16

SAL 22

160 W

10 A

22

SAL 33

180 W

16 A

33

SAL 50

400 W

16 A

50

SAL 85

680 W

25 A

85

SAL 125

1000 W

25 A

125

SAL 175

1020 W

25 A

175

SAL 250

2880 W

25 A

250

Electrical consumption

Hidrolife synchronized with filtration

In case of using an 

external clock 

for filtration 

control, make sure that the system is synchronized with the 
filtration of the pool and stops if the water circulation comes 
to a halt. In case of using the 

internal timers

 of the device, the 

unit should permanently be connected to 230 V / 125 V (see 
guide for electrical connection).

Titanium cell connection overheating

Ensure all electrical connections are firmly fixed to 

avoid false contacts and subsequent overheating of system 
components (especially concerning the electrolysis cell with 
usage above 400 W).

SYSTEM INSTALLATION

3

INITIAL WATER ADJUSTMENTS

1

1

2

2

3

Adjust the alkalinity between 90 and 110 ppm’s.
Adjust the pH between 7,2 y 7,5.
Adjust the chlorine between 1 y 1,5 ppm’s.

Add 5 to 6 grams of salt 

(without iodine) for each liter of water in your swimming 

pool (5 to 6 kg NaCl per m

3

 water). 

Open the bottom valve of your swimming pool and add the salt directly to your 
swimming pool water. Let the circulation pump run during the first 24 hours.

 

In case the water is supplied from a well:  
Shock chlorination with trichloroisocyanuric acid  
(2 kg / 50 m

3

 of water).

 

Hidrolife system may operate while the salt is dissolving. 

 

Hidrolife system will operate without problems with salt concentrations from 2,5 g/l to 50 g/l.

 

In pools which receive large amounts of strong sunlight, it’s necessary to add 40 gr/m

3

 of  

stabiliser (isocyanuric acid).

Water adjustments

Adding salt to the water / conductivity

4

FUNCTIONING OF THE SYSTEM

4

5

Main screen 

Cover

Pol 1

LOW

22

gr/h

electrolysis

measures

pH

7.5 OFF

OFF

7.0

7.2

Rx

mV

700 OFF

FL1

700

man

off

man

off

12:30

25º

Current time

Electrolysis 

Intensity of the production in gr/h

Automatic measurements

  

pH / redoX / free chlorine / conductivity 

(according to model)

 

Communications

red

 Communication error

  

Heating ON/OFF

Manual

Automatic

Heating

Smart

Intelligent

man

aut

hea
smt

int

State filtration relay

(see section 4.3 - Filtration)

Water temperature

Production automatically reduced to 

the % selected 

(see display 

1.3

)

Pol 1

Polarity 1 / 

           

Polarity 2

Filtration stopped due to lack of water flow  

Waiting time

Flow

LOW

---

Pol 2

Lack of conductivity or salt / scale on cell /  

exhausted cell 

(check working hours)

Cover

7.5

7.0

ON/OFF

AL3

Setpoint pH maximum (acid control)

Setpoint pH minimum (base control)

Function of acid pump and base pump
Maximum dosing time exceeded 

(   to reset the alarm)

Flow alarm / 

           

Error rotameter Cl

2

700

FL 1

ON/OFF

FL 2

Function of chlorine pump

Setpoint redoX minimum

State relay lighting

Manual /            Automatic

man

aut