Acid dosing pump
(optional - for models with PH control)
Acid injector
(optional - for models with PH control)
Hydrochloric acid container
(optional, for models with PH control,
not supplied with unit)
A
B
C
Filtration pump timer
Silex / glass / diatom filter
Recirculation pump
1
3
4
5
Electronic box
Electrolysis cell
(always in vertical position)
pH probe
(optional - for models with pH control)
redoX probe
(optional - for models with redoX control)
8
9
10
15
16
17
Other pool equipment
Module RF or RF/WIFI or WIFI
Free chlorine control
Product
Maximum
consumption
Recommended
protection
gr Cl
2
/h
SAL 8
80 W
10 A
8
SAL 16
120 W
10 A
16
SAL 22
160 W
10 A
22
SAL 33
180 W
16 A
33
SAL 50
400 W
16 A
50
SAL 85
680 W
25 A
85
SAL 125
1000 W
25 A
125
SAL 175
1020 W
25 A
175
SAL 250
2880 W
25 A
250
Electrical consumption
Hidrolife synchronized with filtration
In case of using an
external clock
for filtration
control, make sure that the system is synchronized with the
filtration of the pool and stops if the water circulation comes
to a halt. In case of using the
internal timers
of the device, the
unit should permanently be connected to 230 V / 125 V (see
guide for electrical connection).
Titanium cell connection overheating
Ensure all electrical connections are firmly fixed to
avoid false contacts and subsequent overheating of system
components (especially concerning the electrolysis cell with
usage above 400 W).
SYSTEM INSTALLATION
3
INITIAL WATER ADJUSTMENTS
1
1
2
2
3
Adjust the alkalinity between 90 and 110 ppm’s.
Adjust the pH between 7,2 y 7,5.
Adjust the chlorine between 1 y 1,5 ppm’s.
Add 5 to 6 grams of salt
(without iodine) for each liter of water in your swimming
pool (5 to 6 kg NaCl per m
3
water).
Open the bottom valve of your swimming pool and add the salt directly to your
swimming pool water. Let the circulation pump run during the first 24 hours.
•
In case the water is supplied from a well:
Shock chlorination with trichloroisocyanuric acid
(2 kg / 50 m
3
of water).
•
Hidrolife system may operate while the salt is dissolving.
•
Hidrolife system will operate without problems with salt concentrations from 2,5 g/l to 50 g/l.
•
In pools which receive large amounts of strong sunlight, it’s necessary to add 40 gr/m
3
of
stabiliser (isocyanuric acid).
Water adjustments
Adding salt to the water / conductivity
4
FUNCTIONING OF THE SYSTEM
4
5
Main screen
Cover
Pol 1
LOW
22
gr/h
electrolysis
measures
pH
7.5 OFF
OFF
7.0
7.2
Rx
mV
700 OFF
FL1
700
man
off
man
off
12:30
25º
Current time
Electrolysis
Intensity of the production in gr/h
Automatic measurements
pH / redoX / free chlorine / conductivity
(according to model)
Communications
red
Communication error
Heating ON/OFF
Manual
Automatic
Heating
Smart
Intelligent
man
aut
hea
smt
int
State filtration relay
(see section 4.3 - Filtration)
Water temperature
Production automatically reduced to
the % selected
(see display
1.3
)
Pol 1
Polarity 1 /
Polarity 2
Filtration stopped due to lack of water flow
Waiting time
Flow
LOW
---
Pol 2
Lack of conductivity or salt / scale on cell /
exhausted cell
(check working hours)
Cover
7.5
7.0
ON/OFF
AL3
Setpoint pH maximum (acid control)
Setpoint pH minimum (base control)
Function of acid pump and base pump
Maximum dosing time exceeded
( to reset the alarm)
Flow alarm /
Error rotameter Cl
2
700
FL 1
ON/OFF
FL 2
Function of chlorine pump
Setpoint redoX minimum
State relay lighting
Manual / Automatic
man
aut