INSTALLATION GUIDE
PORTABLE
COLOR
DISPLAY
(TFT)
WORLDWIDE
REMOTE
CONTROL
WIFI and
MODBUS
SEA
WATER
SELF
CLEAN
UPGRADE
POSSIBLE
from
SALT/L
3g
Optional automatic controls
Conductivity
Metering and control of
the conductivity of the
water in Msiemens.
Flow detector
Temperature
Mechanic security
flow switch. Stops the
electrolysis if there is no
water flow.
Temperature probe
0 - 100° C necessary
to activate the filtration
modes: heating /
intelligent / smart.
1
The salt water electrolysis produces
chlorine on the bases of salt water of low
salinity (approximately 5 g salt per liter).
As the swimming pool water containing
the salt flows through the electrolysis
cell, the salt is converted to sodium
hypochlorite (liquid chlorine). Organic
matter present in the water is oxidized
and eliminated by the chlorine. The
sodium hypochlorite reconverts into salt
on its way back to the swimming pool.
DESCRIPTION
Electronic box
Ventilation
grid
8
3.15 A fuse
250 mA fuse
Fuse relays 3.15 A
5
6
7
Electrolysis
RCA flow detector
Main connection 220 V
ON/OFF switch
1
2
3
4
1
2
3
4
5
6
7
8
8
Cell
1
2
3
4
5
Electrolysis cell
RCA flow detector
Cell connector
Flow/gas detector
Cell housing
1
2
3
4
5
redoX control
Free chlorine control
pH control
Metering and control
of the pH of the water.
Metering and control of
the redoX as check value
of the free chlorine.
Metering and control in
ppm of the free chlorine
of the water.
Electrical connections of the electronic box
Conductivity probe
Temperature probe
RELAY 1 - pH
(pH Control)
Connection WIFI / RS module
Device control SLAVE
Digital inputs / outputs
Connection display
RELAY 2 - Filtr
(Filtration control)
RELAY 3 - Lighting
(Lighting control)
RELAY 4 - AUX 1
(Base)
RELAY 5 - AUX 2
(Chlorine / RedoX / Ozone)
RELAY 6 - AUX 3
(CD / UV)
RELAY 7 - AUX 4
(Heat pump)
pH
redoX
Free
Chlorine
Chlorine probe
detector
(rotameter)
Cover
ATTENTION:
230 V
Output