VIII. Functions of Six-Way Valve and 
 

    Meaning of its Positions

 

 

 

 

 

 

 

 

 

General instructions:

1.  The valve stud is set for adjustable pressure gauge.
2.   Reparation and maintenance of the valve: (Before initiation of your work, turn the pump off and close  
 

the valve of the suction and draining pipes).

 

a.

 Set the bar in the position FILTER.

 b. 

Remove the screws from the cover.

 c.

 Pull and remove the cover and the valve separator set.

Setting up:

1.  Place the valve separator in a way that the separator opening is on the TOP neck (lever is in the position  
 FILTER). 

The 

fl

 at edge of the cover screw stud must be in the same level as the 

fl

 at edge of the body   

 screw 

stud.

2.   Put the O-ring of the cover on.
3.   Ensure the assembly on the body by screws of the cover. Tighten them equally and alternatively. Do not  
 over 

tighten.

Position of the valve 

Functions

FILTRATION

Standard 

fi

 ltration and suction.

RINSE

Cleaning the 

fi

 ltration by the inverse 

fl

 ow.

FILTRATION PROCESS (BACKWASH) 

is used to rinse out the dirt from the 

fi

 ltration after the rinse.

WASTE

Filter bypass is used for the drain suction or lowering the water level.

RECIRCULATION

Filter bypass for water pumping to the pool without 

fi

 ltration.

CLOSED

Closing of the 

fl

 ow to the 

fi

 lter or to the pool.

        FILTRATION   

 

    WASTE 

 

 

         CLOSED

 

  Waste   

 

       

       Waste 

 

 

               Waste

             Input   Output 

 

     

      Input   Output 

 

            Input   Output 

   

BACKWASH  

                 RINSE                                  RECIRCULATION

 

   Waste   

 

       

         Waste 

 

 

                Waste

             Input   Output 

 

     

      Input   Output 

 

            Input   Output 

EN

Содержание FSP350

Страница 1: ...COMPLETE SAND FILTRATION WITH SIX WAY VALVE AND PUMP ON BASE PLATE Models FSP350 FSP450 FSP500 FSP650 INSTALLATION AND USER GUIDE EN i Please read the user manual ...

Страница 2: ...ve components 6 VII List of pump components 7 VIII Functions of six way valve and meaning of its positions 8 Thank you for choosing our product and for trusting our company Please read the instructions carefully and follow the steps indicated in our user guide before the initiation of this product in order to avoid the damage of the equipment or unwanted injury EN ...

Страница 3: ...ration II Installation Assemble the filtering system including the pump the filtering tank and the six way valve The filtering system should be fitted as close to the pool as possible possibly 0 5 metre under the water level in the pool Make sure that water can run off from the place where the filter is installed PUMP 1 The pump and the electric power line should only be installed by qualified and...

Страница 4: ...ns are duly tightened to prevent water leakage III Main proportions Maximum water temperature 40 C Maximum operating pressure 200 kPa Sand grain size 0 5 0 8 mm Table of dimensions Model Weight A mm Diameter B mm Length C mm Sand kg Design discharge m3 hour Power input kW Voltage V FSP350 680 350 555 20 4 0 20 230 FSP450 813 449 760 45 8 0 50 230 FSP500 856 527 760 85 12 0 75 230 FSP650 961 627 76...

Страница 5: ...r doesn t leak from the system and the filter and if necessary tighten the connections screws or nuts 6 Write down the pressure while initiating the filtration cycle when the filtration is clean This value will vary according to the pool used pump and the length and shape of pipes After some time the pressure will increase and the water flow will reduce due to the accumulation of the dirt in the f...

Страница 6: ... wheel 10 Revolving wheel 11 Filtration bag spider 12 Body diffuser 13 O ring of the end piece 14 Adapting pipe of the end piece 15 O ring of the end piece 16 End piece adapter 17 End piece nut 18 O ring of the central pipe 19 O ring of the filter 20 Screw with a nut clamp 21 Flange clamp 22 Overflow diffuser 23 Nut plug 24 Plug with the O ring 25 Waste aperture 26 Connector EN ...

Страница 7: ...ary filter lid 3 Capillary filter 4 Pump body 5 Connecting screw coupling 6 Drain screw with O ring 7 O ring with diffuser 8 Diffuser 9 Impeller 10 Screw M 8x16 11 Complete shaft seal 12 Pump body O ring 13 Flange between pump and motor 14 Screw M 6x30 15 Dust cover 16 Supporting stud 17 Motor EN ...

Страница 8: ... level as the flat edge of the body screw stud 2 Put the O ring of the cover on 3 Ensure the assembly on the body by screws of the cover Tighten them equally and alternatively Do not over tighten Position of the valve Functions FILTRATION Standard filtration and suction RINSE Cleaning the filtration by the inverse flow FILTRATION PROCESS BACKWASH is used to rinse out the dirt from the filtration a...

Страница 9: ...n the filter cover nor the filter container with a solvent it could damage its surface tarnishing transparency etc Clean regularly the capillary filter of the pump and the skimmer basket in order to prevent the damage of the pump and ensure the proper operation of the system Do not screw out flanged connectors if the pump is running All connectors are equipped with the padding therefore there is n...

Отзывы: