Quantura Q10+ Laundry Dosing System
Safety Notes
IMPORTANT:
Please read the following precautions
carefully before using this equipment.
This appliance can be used by children age from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning
and user maintanence shall not be made by children
without supervision.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly
qualified persons in order to avoid hazard.
Before Installation
Ensure you have checked all parts required are
present and inspect for any damage before
installation. In the unlikely event your items are
faulty,
DO NOT
install faulty or damaged parts as this
unsafe and will void any warranty. Please return to
your distributor in the original delivery condition
including any packaging. This unit is
ONLY
to be
installed by a suitably qualified person complying
with local regulations.
Quantura
Q10+
Peristaltic
tubing
× 1
(Silicone 5mm )
Ceramic weight
and foot filter
× 1
Remote dose
controller x1
PVC Tubing
1 x 3m (10ft)
Fixings Pack:
Screws × 2
Wall plugs ×2
Installation
Mounting and connection
Step 1:
Using the wall plugs and screws
specified for this unit, fix the mounting
bracket to the wall. There is an embedded
spirit level to aid with this part of the
installation.
Step 2:
Mount the unit to the wall by
hooking it onto the wall bracket. As you push
the unit down you should hear a click sound.
Step 3:
Ensure there is no power to the
unit Remove front cover by turning thumb
screw anti-clockwise and pulling the front
cover towards you as shown.
Step 4:
Insert one end of the tube ensuring
that it is slotted into the body of the
enclosure as shown.
INFORMATION:
Silicone grease provided
must be applied to the tube and the pump &
rotor assembly before the tube is inserted.
Failure to apply the grease will affect the
pump performance during operation.
Step 5:
Now by manually rotating the
pump head, feed the tube into the unit as
shown.
IMPORTANT
to aid prolonging tube life and
efficent running, please use the
Silicone
Grease
(supplied) on the outer of the tube.
Spread liberally to the outside of the tube to
help ease installation, this will also aid
continuous smooth operation and help
prevent any potential snagging.
Step 6:
Now insert the other end of the
tube ensuring that it is slotted into the body
of the enclosure as shown.
IMPORTANT INFORMATION:
Brightwell
Dispensers Ltd (manufacturer) accepts no
responsibility and/or damages caused to
either the product or premises if the
installation process is not complied with in
full.
.
Connecting Chemicals
Step 1:
Ensure there is no
power to the unit, push the tube
adaptors into the clamps nuts.
Then tighten the clamp nuts.
Step 2:
Connect the suction
tube from the chemical
container to
(A)
. Now connect
the delivery tube from
(B)
to the
injection point.
Power Supply
Should the supply cord be damaged, it should be replaced by the
manufacturer or its service agent or a similarly qualified person in
order to avoid a hazard.
Connecting or Replacing Handset
Step 1
: Offer up the connector
handset to the connector of the
unit (positioned underneath the
pump). Make sure the connector
is lined up correctly as it will only
fit in a certain position.
Step 2:
Tighten the connector by
turning it clockwise until finger
tight.
Note:
Do not overtighten
.
This unit contains high voltage
circuits that may expose you to the
danger of electric shock.
Means for disconnection must be
incorporated in accordance with the
wiring rules.
Do not
open the enclosure without
isolating the signal and supply
sources. Ensure that these sources
have been isolated for at least 5
minutes before entering the
enclosure.
Do not
power the unit outside of the
values stated on the rating label.
Do not
use damaged or frayed
cables.
Do not
dismantle or modify this
equipment.
Never
insert fingers into mechanisms
without turning the power supply off
first.
Do not
mount the unit to unstable,
irregular or non-vertical surfaces.
Do not
place heavy objects on top of
the unit.
Do not
attempt to place items (such as
screwdrivers) into the moving parts of
the pump head.
Always
ensure that care is taken
when handling chemicals.
Do not
discard of the manual, this
must be retained.
This unit must be installed by suitably qualified
personnel in accordance with local regulations,
or in the absence of local regulations, installed
in accordance with the applicable
requirements in the National Electrical Code,
NFPA 70, Canadian Electrical Code (CEC),
Part 1, CSA C22.1, and Standard for
Ventilation Control and Fire Protection of
Commercial Cooking Operations, NFPA 96.
A
B
Wire Colours
ROW
US
Blue
Black
Brown White