background image

 

 

 

Quantura Q10+ Laundry Dosing System

 

Safety Notes 

 

IMPORTANT: 

Please  read  the  following  precautions 
carefully  before  using  this  equipment. 

 

 

 

This appliance can be used by children age from 8 
years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience 
and knowledge if they have been given supervision 
or instruction concerning use of the appliance in a 
safe way and understand the hazards involved. 
Children shall not play with the appliance. Cleaning 
and user maintanence shall not be made by children 
without supervision.

 

If the supply cord is damaged, it must be replaced by 
the manufacturer, its service agent or similarly 
qualified persons in order to avoid hazard. 

Before Installation 

 

Ensure you have checked all parts required are 
present and inspect for any damage before 
installation. In the unlikely event your items are 
faulty, 

DO NOT 

install faulty or damaged parts as this 

unsafe and will void any warranty. Please return to 
your distributor in the original delivery condition 
including any packaging. This unit is 

ONLY

 to be 

installed by a suitably qualified person complying 
with local regulations. 

 
 

Quantura  
Q10+ 

 

Peristaltic 
tubing 

× 1 
(Silicone 5mm ) 

 

Ceramic weight 
and foot filter 

× 1

 

 

Remote dose  
controller x1

 

 

PVC Tubing

 

1 x 3m (10ft)

 

 

Fixings Pack: 

 

Screws × 2

 

Wall plugs ×2 

 

 

 

Installation 

 

 

 

 

 

 

 

 

 

 

 

 

 
Mounting and connection 

 

Step 1:

 

Using the wall plugs and screws 

specified for this unit, fix the mounting 
bracket to the wall. There is an embedded 
spirit level to aid with this part of the 
installation. 

 
 
 

Step 2:

 

Mount the unit to the wall by 

hooking it onto the wall bracket. As you push 
the unit down you should hear a click sound. 

 
 

 
Step 3:

 

Ensure there is no power to the 

unit Remove front cover by turning thumb 
screw anti-clockwise and pulling the front 
cover towards you as shown. 

 

 

 

Step 4:

 Insert one end of the tube ensuring 

that it is slotted into the body of the 
enclosure as shown.

  

INFORMATION:

 

Silicone grease provided 

must be applied to the tube and the pump & 
rotor assembly before the tube is inserted. 
Failure to apply the grease will affect the 
pump performance during operation.

 

 

Step 5:

 

Now by manually rotating the 

pump head, feed the tube into the unit as 
shown.  

IMPORTANT

 

to aid prolonging  tube life and 

efficent running, please use the 

Silicone 

Grease

 (supplied) on the outer of the tube. 

Spread liberally to the outside of the tube to 
help ease installation, this will also aid 
continuous smooth operation and help 
prevent any potential snagging. 

 
 

Step 6:

 

 Now insert the other end of the 

tube ensuring that it is slotted into the body 
of the enclosure as shown. 

 
 
IMPORTANT INFORMATION:

 

Brightwell 

Dispensers Ltd (manufacturer) accepts no 
responsibility and/or damages caused to 
either the product or premises if the 
installation process is not complied with in 
full.

 

.

 

 
 
 
 

Connecting  Chemicals 

 

 

 
Step 1:

 

Ensure there is no 

power to the unit, push the tube 
adaptors into the clamps nuts. 
Then tighten the clamp nuts. 

 
 
 
 

 

 

Step 2: 

Connect the suction 

tube from the chemical 
container to 

(A)

. Now connect 

the delivery tube from 

(B)

 to the 

injection point.

 

 
 

 

Power Supply 

 
Should the supply cord be damaged, it should be replaced by the 
manufacturer or its service agent or a similarly qualified person in 
order to avoid a hazard.  

 

 

Connecting or Replacing Handset 

 

 

 
Step 1

: Offer up the connector 

handset to the connector of the 
unit (positioned underneath the 
pump). Make sure the connector 
is lined up correctly as it will only 
fit in a certain position. 

 

 
 

 

 
Step 2:

 Tighten the connector by 

turning it clockwise until finger 
tight.  

Note:

 

Do not overtighten

  

 

.  

 
 
 

 

This  unit  contains  high  voltage 
circuits that may expose you to the 
danger of electric shock. 

 

 

Means for disconnection must  be 
incorporated in accordance with  the 
wiring  rules. 

 

 

Do not

 open the enclosure without 

isolating the signal  and supply 
sources. Ensure that these sources 
have been isolated for at least 5 
minutes before entering the 
enclosure. 

 

 

Do not

 power the unit outside of the 

values stated on the rating label. 

 

 

Do not

 use damaged or frayed 

cables. 

 

 

Do not

 dismantle or modify this 

equipment. 

 

 

Never 

insert fingers into mechanisms 

without turning the power supply off 
first. 

 

 

Do not

 mount the unit to unstable, 

irregular or non-vertical surfaces. 

 

 

Do not

 place heavy objects on top of 

the unit. 

 

 

Do not

 attempt to place items (such as 

screwdrivers) into the moving parts of 
the pump head. 

 

 

Always

  ensure that care is taken 

when handling chemicals. 

 

 

Do not

 discard of the manual, this 

must be retained. 

 

 

 

This unit must be installed by suitably qualified 
personnel in accordance with local regulations, 
or in the absence of local regulations, installed 
in accordance with the applicable 
requirements in the National Electrical Code, 
NFPA 70, Canadian Electrical Code (CEC), 
Part 1, CSA C22.1, and Standard for 
Ventilation Control and Fire Protection of 
Commercial Cooking Operations, NFPA 96. 

 
 
 
 
 
 
 

 

Wire Colours 

 

ROW 

US 

Blue 

Black 

Brown  White 

 

Отзывы: