Quick Start Guide for Q10 & Q10+ English
M00015-EN-22/03/17-V1.1
Quantura Q10 & Q10+
Dishwash Dosing System
Safety Notes
IMPORTANT:
Please read the following precautions
carefully before using this equipment.
This appliance can be used by children age from 8
years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the
hazards involved. Children shall not play with the
appliance. Cleaning and user maintanence shall
not be made by children without supervision.
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid hazard.
Before Installation
Ensure you have checked all parts required are
present and inspect for any damage before
installation. In the unlikely event your items are
faulty,
DO NOT
install faulty or damaged parts as
this unsafe and will void any warranty. Please
return to your distributor in the original delivery
condition including any packaging. This unit is
ONLY
to be installed by a suitably qualified person
complying with local regulations.
Quantura
Q10 & Q10+
Peristaltic
tubing
× 1
(Silicone 5mm OR
Norprene 3mm)
Ceramic weight
and foot filter
× 1
Rinse or
Detergent
Injector
× 1
Polyethylene
Tubing
3000mm × 1
Fixings Pack:
Screws × 2
Wall plugs ×2
Installation
Mounting and connection
Step 1:
Using the wall plugs and screws
specified for this unit, fix the mounting
bracket to the wall. There is an embedded
spirit level to aid with this part of the
installation.
Step 2:
Mount the unit to the wall by
hooking it onto the wall bracket. As you push
the unit down you should hear a click sound.
Step 3:
Ensure there is no power to the
unit Remove front cover by turning thumb
screw anti-clockwise and pulling the front
cover towards you as shown.
Step 4:
Insert one end of the tube ensuring
that it is slotted into the body of the
enclosure as shown.
Step 5:
Now by manually rotating the pump
head, feed the tube into the unit as shown.
TIP
use some HT5 Silicone grease on the
outer of the tube to help ease the tube in and
prevent any snagging.
Step 6:
Now insert the other end of the
tube ensuring that it is slotted into the body
of the enclosure as shown.
IMPORTANT INFORMATION:
Brightwell
Dispensers Ltd (manufacturer) accepts no
responsibility and/or damages caused to
either the product or premises if the
installation process is not complied with in
full.
.
Connecting Chemicals
Step 1:
Ensure there is no
power to the unit, connect the
suction tube from the detergent
or rinse container to
(A)
. Now
connect the delivery tube from
(B)
to the injection point.
Installation connection
Should the supply cord be damaged, it should be replaced by the
manufacturer or its service agent or a similarly qualified person in
order to avoid a hazard.
SPEED
TIMED
Rinse Rake
Solenoid
Valve
Wash Cycle
Run Lamp
Coil of Wash
Contactor
Cam Timer
Power Supply
Should the supply cord be damaged, it should be replaced by the
manufacturer or its service agent or a similarly qualified person in
order to avoid a hazard.
This unit contains high voltage
circuits that may expose you to the
danger of electric shock.
Means for disconnection must be
incorporated in accordance with the
wiring rules.
Do not
open the enclosure without
isolating the signal and supply
sources. Ensure that these sources
have been isolated for at least 5
minutes before entering the enclosure.
Do not
power the unit outside of the
values stated on the rating label.
Do not
use damaged or frayed cables.
Do not
dismantle or modify this
equipment.
Never
insert fingers into mechanisms
without turning the power supply off
first.
Do not
mount the unit to unstable,
irregular or non-vertical surfaces.
Do not
place heavy objects on top of
the unit.
Do not
attempt to place items (such as
screwdrivers) into the moving parts of
the pump head.
Always
ensure that care is taken when
handling chemicals.
Do not
discard of the manual, this
must be retained.
This unit must be installed by suitably qualified
personnel in accordance with local regulations,
or in the absence of local regulations, installed
in accordance with the applicable requirements
in the National Electrical Code, NFPA 70,
Canadian Electrical Code (CEC), Part 1, CSA
C22.1, and Standard for Ventilation Control
and Fire Protection of Commercial Cooking
Operations, NFPA 96.
Detergent
Rinse Aid Dosing
A
B