Safety Notes 

 

IMPORTANT: 

Please  read  the following  precautions 
carefully  before  using  this  equipment. 

 

 

 

This appliance can be used by children age from 8 
years and above and persons with reduced 
physical, sensory or mental capabilities or lack of 
experience and knowledge if they have been given 
supervision or instruction concerning use of the 
appliance in a safe way and understand the 
hazards involved. Children shall not play with the 
appliance. Cleaning and user maintanence shall 
not be made by children without supervision.

 

If the supply cord is damaged, it must be replaced 
by the manufacturer, its service agent or similarly 
qualified persons in order to avoid hazard. 

Before Installation 

 

Ensure you have checked all parts required are 
present and inspect for any damage before 
installation. In the unlikely event your items are 
faulty, 

DO NOT 

install faulty or damaged parts as 

this unsafe and will void any warranty. Please 
return to your distributor in the original delivery 
condition including any packaging. This unit is 

ONLY

 to be installed by a suitably qualified person 

complying with local regulations. 

 
 

Quantura  
Q10 & Q10+ 

 

Peristaltic 
tubing 

× 1 
(Silicone 5mm  OR 
Norprene 3mm) 

 

Ceramic weight 
and foot filter 

× 1

 

 

Rinse or 
Detergent 
Injector 

× 1 

 

Polyethylene 
Tubing

 

3000mm × 1

 

 

Fixings Pack: 

 

Screws × 2

 

Wall plugs ×2 

 

 

 

 

 

Installation 

 

 

 

 

 

 

 

 

 

 

 

 

 
Mounting and connection 

 

Step 1:

 

Using the wall plugs and screws 

specified for this unit, fix the mounting 
bracket to the wall. There is an embedded 
spirit level to aid with this part of the 
installation. 

 
 
 

Step 2:

 

Mount the unit to the wall by 

hooking it onto the wall bracket. As you push 
the unit down you should hear a click sound. 

 
 

 
Step 3:

 

Ensure there is no power to the 

unit Remove front cover by turning thumb 
screw anti-clockwise and pulling the front 
cover towards you as shown. 

 

 

 

 

 

Step 4:

 Insert one end of the tube ensuring 

that it is slotted into the body of the 
enclosure as shown. 

 
 
 
 

Step 5:

 Now by manually rotating the pump 

head, feed the tube into the unit as shown. 

TIP 

 use some HT5 Silicone grease on the 

outer of the tube to help ease the tube in and 
prevent any snagging.  

 
 
 
 
 

Step 6:

 

 Now insert the other end of the 

tube ensuring that it is slotted into the body 
of the enclosure as shown. 

 
 
 
 
 
 
IMPORTANT INFORMATION:

 

Brightwell 

Dispensers Ltd (manufacturer) accepts no 
responsibility and/or damages caused to 
either the product or premises if the 
installation process is not complied with in 
full.

 

.

 

Connecting  Chemicals 

 

 

Step 1:

 

Ensure there is no 

power to the unit, connect the 
suction tube from the detergent 
or rinse container to 

(A)

. Now 

connect the delivery tube from 

(B)

 to the injection point.

 

 

 

 

Installation connection  

 

Should the supply cord be damaged, it should be replaced by the 
manufacturer or its service agent or a similarly qualified person in 
order to avoid a hazard.  
 
 

SPEED

 

TIMED

 

 

 

 

 

 

 

 

 

 

 

Rinse Rake 

 

Solenoid 

Valve

 

Wash Cycle 

Run Lamp 

 

Coil of Wash 

Contactor 

 

Cam Timer 

 
 

 

 

 

 
 

 

 

 

Power Supply 

 
Should the supply cord be damaged, it should be replaced by the 
manufacturer or its service agent or a similarly qualified person in 
order to avoid a hazard.  

 

 
 
 

 

This unit contains  high  voltage 
circuits that may expose you to the 
danger of electric shock. 

 

 

Means for disconnection must  be 
incorporated in accordance with  the 
wiring  rules. 

 

 

Do not

 open the enclosure without 

isolating the signal  and supply 
sources. Ensure that these sources 
have been isolated for at least 5 
minutes before entering the enclosure. 

 

 

Do not

 power the unit outside of the 

values stated on the rating label. 

 

 

Do not

 use damaged or frayed cables. 

 

 

Do not

 dismantle or modify this 

equipment. 

 

 

Never 

insert fingers into mechanisms 

without turning the power supply off 
first. 

 

 

Do not

 mount the unit to unstable, 

irregular or non-vertical surfaces. 

 

 

Do not

 place heavy objects on top of 

the unit. 

 

 

Do not

 attempt to place items (such as 

screwdrivers) into the moving parts of 
the pump head. 

 

 

Always

  ensure that care is taken when 

handling chemicals. 

 

 

Do not

 discard of the manual, this 

must be retained. 

 

 

 

This unit must be installed by suitably qualified 
personnel in accordance with local regulations, 
or in the absence of local regulations, installed 
in accordance with the applicable requirements 
in the National Electrical Code, NFPA 70, 
Canadian Electrical Code (CEC), Part 1, CSA 
C22.1, and Standard for Ventilation Control 
and Fire Protection of Commercial Cooking 
Operations, NFPA 96. 

 
 
 
 
 