Brightline 1.4D/X Скачать руководство пользователя страница 4

4

Doc: 019-156.P65
Rev: C

Table 1

DMX Cable Layout

1 = GND
2 =  DATA -
3 =  DATA +

1 =  GND
2 =  DATA -
3 =  DATA +

RUN

UP

DOWN

DMX

DMX LED OFF =  NO SIGNAL
DMX LED ON = UNUSABLE SIGNAL
DMX LED FLASH = OK

I = 2 LAMPS
0 = OFF
II =  4  LAMPS

120 VAC
60 HZ.

10 A MAX.

DMX  LED OFF  = NO SIGNAL
DMX  LED ON =  UNUSABLE SIGNAL
DMX  LED FLASH =  OK

DOWN

DMX

RUN

1 = GND
2 =  DATA -
3 =  DATA +

1 = GND
2 = DATA -
3  = DATA +

10 A MAX.

120 VAC
60 HZ.

I = 2 LAMPS
0   =  OFF
II  = 4  LAMPS

UP

START CHANNEL

DMX LED  OFF =  NO SIGNAL
DMX LED ON = UNUSABLE SIGNAL
DMX LED FLASH = OK

1 =  GND
2 =  DATA -
3 =  DATA +

1 =  GND
2 = DATA -
3 = DATA +

RUN

DMX

UP

ON/OFF

I = 2 LAMPS
0 =  OFF
II =  4 LAMPS

AC IN

120 VAC
60 HZ.

AC THRU

10 A  MAX.

DOWN

ON/OFF

START CHANNEL

AC THRU

AC IN

START CHANNEL

ON/OFF

AC IN

AC THRU

R

R

R

MTX Cable

To Next Fixture

DMX

IN

DMX

THRU

DMX

IN

DMX

THRU

DMX

IN

DMX

THRU

Lighting Control

Console

XLR Pin Num-

DMX Wire

1

2
3

Common

DMX -
DMX +

4
5

Not Used
Not Used

DMX Networking Guidelines

If you are connecting more than one DMX fixture, you must understand how to configure a DMX network. If you
follow the guidelines below, it should reduce the possibility of networking errors.

1. Fixtures and other devices in a DMX network need to be configured in a daisy-chain fashion. The use of DMX "Y"
    devices or "twofers" is not allowed.

2. You can use up to 32 brightline DMX fixtures on a single DMX data line. If there are more than 32 units, the use
    of a DMX repeater amplifier or splitter amplifier is required. A repeater amplifier is an electronic device which
    boosts the DMX signal. A splitter amplifier is an electronic device which boosts the DMX signal and provides
    for multiple DMX outputs from a single DMX input (Using multiple DMX devices may cause signal degradation).

3. With most DMX devices, there is a "DMX Thru/DMX Terminate" switch that is set to "Terminate" for the last
    device on the data line, and "Through" for all the others. brightline DMX fixtures are self-terminating, and this
    switch is not provided.

4. brightline fixtures, as with the majority of DMX devices, use 5 pin XLR-type plugs wired according to (Table 1).
    Pins 4 & 5 are not used; and on brightline fixtures, are not connected. Pin 1 (Shield) should be connected to
    Earth Ground only at the Control Console.

5. Only cables intended for DMX operation should be used. Avoid DMX runs parallel to power cables, particularly
    those from dimmer racks.

    Note: These guidelines will help the user configure most DMX networks. For more information, contact the
    manufacturer of the control console, or a DMX manual. A useful DMX guide is "Recommended Practice for
    DMX-512" by Adam Bennette, co-published by PLASA in the United Kingdom and USITT in North America.

Содержание 1.4D/X

Страница 1: ...4D X 1 4D XE Operating Instructions supplements 1 4N 1 4D operating instructions 580 Mayer Street Building 7 Bridgeville PA 15017 phone 412 206 0106 fax 412 206 0114 www brightlines com 2001 brightline L P ...

Страница 2: ...st to reset 3 Install new lamp 4 Turn fixture ON Warning Turn fixture OFF before connecting or disconnecting fixture to DMX control cable or damage to ballast may result Do not service fixture until the appropriate service manual has been read and the unit has been completely de energized All fixtures are fuse protected To prevent fire or shock hazard do not expose the unit to water or moisture Do...

Страница 3: ...Socket F Power Inlet Module with Fuse S Reflector G Rocker Switch T Lamp Clip H Male 5 Pin XLR Receptacle U 6 32 Nut I Female 5 Pin XLR Receptacle V Nylon Spacer J Ballast Housing W 4 40 x 25 Lg Screw K Ballast X 6 32 x 25 Lg Screw L Signal Convertor Y 6 32 Tinnerman Nut M Main Housing Z 6 32 x 25 Black Oxide Screw X D N P Y O T M Q Z L W R G E F A C B J U V K H I S ...

Страница 4: ...ofers is not allowed 2 You can use up to 32 brightline DMX fixtures on a single DMX data line If there are more than 32 units the use of a DMX repeater amplifier or splitter amplifier is required A repeater amplifier is an electronic device which boosts the DMX signal A splitter amplifier is an electronic device which boosts the DMX signal and provides for multiple DMX outputs from a single DMX in...

Страница 5: ...eceptacle until locked into place 5 Route the jumper cable to the next fixture 6 Lineup the locking key on the female plug end of the jumper cable Figure 2 with the male receptacle labeled DMX IN on the next fixture Insert the plug into the receptacle until locked into place 7 Repeat steps 4 6 for remaining fixtures 8 Turn Power ON on all devices Intalling DMX Control Cables Figure 5 Figure 6 3 To...

Страница 6: ... control console Use Table 2 to evaluate the readout of the channel indicator on the LED display Figure 7 2 The DMX signal indicator is used to determine if the fixture is receiving a DMX signal while using the Console Dimming Mode The lighting control console and all necessary DMX cabling must be installed Use Table 3 to evaluate the readout of the DMX signal indicator on LED display Figure 7 3 T...

Страница 7: ...ture in DMX system 1 Turn lighting control console power ON 2 Check connections at first fixture and lighting control console or try another DMX cable No DMX signal on a single fixture or group of fixtures in the DMX system Cabling or connection problem with jumper cable Check connection of jumper cable between fixture with no signal and previous fixture in DMX system or try another DMX jumper cab...

Страница 8: ...8 Doc 019 156 P65 Rev C Wiring Diagram 1 4D X 120V Wiring Diagram 1 4D XE 230V Note Use 10 amp time delay 250 volts 5 x 20mm fuses only Note Use 10 amp time delay 250 volts 5 x 20mm fuses only ...

Страница 9: ...9 Notes ...

Отзывы: