TOP / LIGHT DIRECTION
INSTALLATION GUIDE
Actual product characteristics may vary. Bright Light reserves the right to improve, modify or update the product designs without prior notice.
ENCAPSULATED LED RIBBON | CURVE | RGB
COLOUR
CODE
LUMENS
RGB
BL-LS-4350-RGB
R 45lm/m
G 180lm/m
B 50lm/m
LED WATTS
12W/m
INPUT VOLTS
24V DC constant voltage
OPERATING TEMP.
-25°C ~ +60°C
MAX. RUN
10m
DIMENSIONS
W10.25 × H17mm
(W12mm for connectors)
CUTTING LENGTH
50mm
MINIMUM BEND
RADIUS
25mm
BEND DIRECTION
Horizontal bending
BEAM ANGLE
180°
SOURCE LIFE
50,000 hours
WARRANTY
3 years
INGRESS
PROTECTION
Protection established by use of
IP65 connections
CONTROL
Requires 3-channel RGB controller
1. Cut Encapsulated LED Ribbon only at
the cut lines shown on Side A of product.
Be conservative to avoid over cutting.
See No. 5 for shortening ribbon.
2.
To fit a connector:
Cut out a notch
(approx 3 × 3mm) from Side A to expose
the underside PCB solder pads. Take
care not to cut or damage the PCB and
LEDs.
SIDE A
Cut mark are visible as darker lines on this side
When connecting cable, notch out from this side
to expose solder pads
INSIDE VIEW - EXPOSE SOLDER PADS
50
SIDE A VIEW - CUT MARKS
CROSS SECTION
1
2
3. Cut and trim the cable to the appropriate length and feed
through connector. Solder the wires onto the solder pads of
the Encapsulated LED Ribbon PCB
ensuring the c,
R,G, B polarity
4.
Insert silicone into connector before fitting over connection.
The silicone is required to complete the IP65 rating.
Failure to
do this will result in warranty becoming void.
5.
Shortening ribbon / fitting new end cap:
Cut Encapsulated
LED Ribbon to length then fit end cap and silicone in place.
SAFETY NOTES
–
Before making any cuts, installation,
maintenance, or connection, be sure
the mains power is disconnected.
–
All connector joints must be connected
correctly to achieve connector IP rating.
–
Check the polarity of the connector
before inserting the front connector and
switching on the mains power.
–
Cut and connect Encapsulated
LED Ribbon correctly. Any incorrect
operation can cause damage.
–
Use a certified Bright Light 24V DC
power supply.
ENCAPSULATED LED RIBBON | CURVE
CAN BE CURVED AS SHOWN BELOW:
CUT OUT NOTCH TO EXPOSE
SOLDER PADS
TOP VIEW - EXPOSE SOLDER PADS
2A
CUT OUT NOTCH
TO EXPOSE
SOLDER PADS
DO NOT TWIST THE LIGHT
OR BEND AGAINST THE
LIGHT SURFACE
0800 952 000 | www.brightlight.co.nz |
BRIGHT
LIGHT
CUTTING RIBBON & CONNECTING BOOT CONNECTORS
ADD SILICONE INTO
CONNECTOR BOOT
BEFORE FITTING
ENSURE THE
C, R,G, B
POLARITY
SOLDER WIRES
SILICONE CONNECTOR
3
CUT MARK
OFFCUT SIDE
CONSERVATIVE CUT
4
17
10.25
BRIGHT LIGHT RECOMMENDS CONNECTIONS ARE MADE IN-HOUSE
LIGHT DIRECTION
HORIZONTAL BENDING
MINIMUM BEND RADIUS
25MM