Functions in details 

DMX channels: 

The XLED may be set to use 3, 4, 6 or 9 DMX channels. 
The channel order is the same for all modes:  

(Please refer to the DMX Charts for detailed description) 

 

Inbuilt Automatic Programs: 

Pr01:  RGBW hard chase 

Sp000:  Stop 

Pr02:  15 Colors hard chase 

Sp001:  Slow 

Pr03:  RGBW soft chase  

 

↓ 

Pr04:  15 Col. soft chase 

Sp100:  Fast 

Pr05:  Random colorfades 

   

Pr06:  Special chaser mode 

   

 

 

   

Special Chaser Mode 

(program Pr06)

 

This mode enables cascading delay being applied to connected slave units, to 
create “running lights” chaser effects without a Lighting console (up to 255 
groups.)  

Settings for the master XLED 

1. Set the DMX address to total number of groups (e.g. 003) 
2. Set Auto Program to 

Pr06 

(master is always part of group 1) 

Settings for the slave XLED’s 

1. Set the DMX address to the desired slave group (e.g. 001, 002 or 003),  
2 Set the fixtures to Slave mode,  

 

 

 

Dim 

Strobe 

Color 

Auto 

Speed 

Содержание 437613

Страница 1: ...1 by Software version 1 4 ...

Страница 2: ...02 287 Ø200 219 263 Width 590 XLED Tourpack 1 x Flightcase 10 x Bright XLED 10 x Hook clamp 10 x Schuko PowerCon 10 x Safety wire Art no XLED basic 1 x Bright XLED 1 x Hook clamp 1 x Schuko PowerCon Art no 437613 ...

Страница 3: ...idity may affect it O Do not connect this device to a dimmer or other regulated power O Only connect this device to a grounded and protected circuit O Switchmode powers has high inrush currents do not exceed 8A on the output Powercon when daisy chaining fixtures 16 units 230V Main Features O High Output 12x8w 4in1 RGBW led engine O Flicker free high speed PWM dimming O Industry standard 5pin XLR a...

Страница 4: ...he main menu with the Up Down buttons and use the Enter Confirm button to select a menu item The XLED will return to its previous state if no new setting or mode has been confirmed within 10 seconds DMX start Address Use Up Down to alter the DMX start Address 001 512 then press Enter Confirm to set the chosen start address permanently O Setting the DMX start Address will activate DMX Mode DMX Chan...

Страница 5: ... Enter to adjust the color temperature W1 W11 then set intensity value D100 000 then press Enter confirm to set Manual White permanently O Setting a manual white will activate Color Set Mode Automatic Programs Use Up Down to select the built in program Pr01 Pr06 press Enter Confirm then use Up Down to select the operating speed of the program Sp000 Sp100 and press Enter Confirm to start Auto Progr...

Страница 6: ...und static or manual color with Master enabled the Master fixture will transmit and remote control any fixtures set to Slave Mode O Setting Master Slave to Slave will activate Slave MODE Factory Reset Use Up Down to select Y for yes then press Enter confirm to reset the fixture to factory default settings O Resetting the fixture will activate DMX Mode ...

Страница 7: ...lorfades Pr06 Special chaser mode Special Chaser Mode program Pr06 This mode enables cascading delay being applied to connected slave units to create running lights chaser effects without a Lighting console up to 255 groups Settings for the master XLED 1 Set the DMX address to total number of groups e g 003 2 Set Auto Program to Pr06 master is always part of group 1 Settings for the slave XLED s 1...

Страница 8: ...8 Photometrics R G B W RGBW 1m 3957 3900 4690 6000 15740 2m 977 1092 1200 1700 4310 3m 430 485 558 747 1911 4m 245 280 308 428 1056 5m 160 185 205 282 693 Beam Angle 22º Field Angle 35º Center Lux ...

Страница 9: ...9 ...

Страница 10: ...9 Red 0 Green 100 0 Blue 100 100 119 Red 0 100 Green 0 Blue 100 120 139 Red 100 Green 0 Blue 100 0 140 159 Red 100 Green 0 100 Blue 0 100 160 179 Red 100 0 Green 100 0 Blue 100 180 200 Red 100 Green 100 Blue 100 White 100 201 255 Color Temperature Warm Cool 8 000 009 No Function 010 049 Auto Program 1 R G B W hard chase 050 090 Auto Program 2 15 colors hard chase 091 131 Auto Program 3 R G B W sof...

Страница 11: ...Constant Current Driver 2940Hz Flicker Free Fuse T2A 250V Optics Light Source 12 pcs of 4in1 RGBW 8W LED Luminous Flux 1m R3957 G3900 B4690 W6000 RGBW15740 Beam Field Angle 22 35 Functions Control Modes DMX512 Static Color Auto Sound Master Slave DMX Channels 3 4 6 9CH Operation Temperature Max ambient temperature Ta 40 C Max housing temperature Tc steady state 80 C Distance Min distance from flam...

Страница 12: ...iliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual Bright Norway AS Brenneriveien 11 N 0182 Oslo Norway brightgroup no ...