9. Repeat steps 2 through 5 to secure the third and fourth

wheels.

10. Attach handles (

H

) to brackets on generator frame as

shown, with 45 mm capscrews (

J

), flat washers (

K

),

nylon washers (

L

), and M8 lock nuts (

M

).

NOTE:

DO NOT overtighten. Handles must be able to move

up and down freely.

11. Return generator to normal operating position (resting

on wheels).

12. To apply brakes, push down firmly on handle of both

clamps until it locks in the down position and engages
the wheels.

IMPORTANT:

The generator is designed to be used on level

surfaces.

13. Loop handle pins (

N

) on generator frame just above

handle brackets.

14. Raise handles and insert handle pins to move

generator.

15. To release brakes, pull up on handle of both clamps

until it locks in the up position.

Add Engine Oil

• Place generator on a level surface.

NOTE:

Verify provided oil bottles are the correct viscosity for

current ambient temperature.

• Refer to engine operator’s manual and follow oil

recommendations and instructions.

NOTE:

Check oil often during engine break–in. Refer to

engine operator’s manual for recommendations.

Add Fuel

NOTE:

Refer to engine operator’s manual and follow fuel

recommendations.

1. Clean area around fuel fill cap, remove cap.

2. Slowly add unleaded gasoline (

A

) to fuel tank (

B

). Be

careful not to fill above the baffle (

C

). This allows

adequate space for fuel expansion as shown.

3. Install fuel cap and let any spilled fuel evaporate before

starting engine.

NOTICE

Any attempt to crank or start the engine before it has been
properly filled with the recommended oil will result in
equipment failure.

• Refer to engine manual for oil information.

• Damage to equipment resulting from failure to follow this

instruction will void warranty.

FUEL

TANK

C

B

A

8

BRIGGSandSTRATTON.COM

WARNING

Fuel and its vapors are extremely flammable and
explosive.

Fire or explosion can cause severe burns or
death.

WHEN ADDING FUEL

• Turn generator OFF and let it cool at least 2 minutes before

removing fuel cap. Loosen cap slowly to relieve pressure in
tank.

• Fill fuel tank outdoors.

• DO NOT overfill tank. Allow space for fuel expansion.

• If fuel spills, wait until it evaporates before starting engine.

• Keep fuel away from sparks, open flames, pilot lights, heat, and

other ignition sources.

• DO NOT light a cigarette or smoke.

Содержание Vox 030339

Страница 1: ...Manual No 205156GS Revision A 01 03 2008 BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A Portable Generator Operator s Manual...

Страница 2: ...l power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thorough...

Страница 3: ...cation 9 Features and Controls 10 Cord Sets and Receptacles 11 Ground Fault Protection 12 Operation 13 Starting the Engine 13 Connecting Electrical Loads 13 Stopping the Engine 14 Operating Automatic...

Страница 4: ...all safety messages that follow this symbol to avoid possible injury or death The safety alert symbol is used with a signal word DANGER WARNING CAUTION a pictorial and or a safety message to alert yo...

Страница 5: ...or fuel expansion If fuel spills wait until it evaporates before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke W...

Страница 6: ...modify generator in any way NOTICE Improper treatment of generator can damage it and shorten its life Use generator only for intended uses If you have questions about intended use ask dealer or contac...

Страница 7: ...locking plug 120 Volt 30 Amp locking plug Install Wheel Kit NOTE Wheel kit is not intended for over the road use You will need the following tools to install these components 3 8 and 13 mm wrench Soc...

Страница 8: ...ne operator s manual for recommendations Add Fuel NOTE Refer to engine operator s manual and follow fuel recommendations 1 Clean area around fuel fill cap remove cap 2 Slowly add unleaded gasoline A t...

Страница 9: ...DO NOT place generator where exhaust gas A could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes...

Страница 10: ...have these readily available if calling for assistance M Idle Control Switch Use this switch to turn the idle control feature on and off N 12 Volt DC Receptacle Use this receptacle with battery charge...

Страница 11: ...phase loads requiring up to 3 600 watts 3 6 kW of power at 30 Amps The outlet is protected by a 2 pole GFCI circuit breaker 120 Volt AC 20 Amp Duplex Receptacle The duplex receptacle is protected aga...

Страница 12: ...oads for 1 minute 2 If circuit breaker tests correctly the electrical equipment or extension cords may be faulty Replace faulty electrical equipment and cords before further use CAUTION If circuit bre...

Страница 13: ...fuel tank causing a fire DO NOT touch hot parts and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead...

Страница 14: ...ONLY distilled water to cover separators in battery cells DO NOT use tap water 2 If battery is equipped with vent caps make sure they are installed and are tight 3 If necessary clean battery terminal...

Страница 15: ...to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NE...

Страница 16: ...aning Daily or before use look around and underneath the generator for signs of oil or fuel leaks Clean accumulated debris from inside and outside the generator Keep the linkage spring and other engin...

Страница 17: ...Off position 2 Remove sediment cup A from fuel valve Remove o ring B retaining ring C and screen D from fuel valve 3 Wash sediment cup o ring retaining ring and screen in a nonflammable solvent Dry th...

Страница 18: ...ilizer in the storage container is recommended to maintain freshness Storing the Engine See the engine operator s manual for instructions on how to properly prepare the engine for storage Other Storag...

Страница 19: ...g 10 Water in fuel 11 Flooded 12 Excessively rich fuel mixture 13 Intake valve stuck open or closed 14 Engine has lost compression 1 Set switch to On position 2 Turn fuel valve to On position 3 Fill c...

Страница 20: ...20 BRIGGSandSTRATTON COM...

Страница 21: ...21...

Страница 22: ...Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty service would not apply if equi...

Страница 23: ...23 23...

Страница 24: ...gle Phase Fuel Capacity 7 U S Gallons 26 5 Liters Model 030340 Starting Wattage 8 125 Watts Wattage 6 500 Watts AC Voltage 120 240 Volts at 240 Volts 27 0 Amps at 120 Volts 54 1 Amps Frequency 60 Hz a...