8
BRIGGSandSTRATTON.COM
7. Tip generator so that engine side is up.
8. Using a 9/16” or 14 mm socket wrench, remove one
existing hex nut (
E
) and lock washer (
F
) from engine
vibration mounts.
9. Slide support leg (
G
) onto engine vibration mount stud
and attach with the lock washer and hex nut. DO NOT
fully tighten.
10. Repeat steps 8 and 9 for second existing hex nut and
lock washer on engine vibration mounts.
11. Using a 9/16” or 14 mm socket wrench, tighten both
hex nuts and lock washers.
12. Repeat steps 8 through 11 for second support leg on
other side.
13. Return generator to normal operating position (resting
on wheels and support leg).
14. Check each fastener to ensure it is secure and the tires
are inflated between 15-40 PSI.
Attach Negative Battery Cable
Your unit is equipped with electric start capability but can be
started manually. If you choose not to use the electric start
feature, you do not need to connect the negative battery
cable.
The sealed battery on the generator pre–installed except for
the negative (black) battery cable.
To install:
1. Cut off tie wrap securing loose end of negative (black)
cable.
2. Using an 8 mm or 5/16” socket wrench, remove
screw (
A
), lock washer (
B
) and flat washer (
C
) on
negative battery terminal.
3. Slide lock washer, flat washer and negative battery cable
(
D
) over screw as shown.
4. Reattach screw to negative battery terminal and tighten.
5. Verify that connections to battery and generator are
tight and secure.
NOTE:
If your battery is discharged, charge prior to use
following the instructions in the section
Battery Charger
.
A
D
C
B