SAE 30

:  

40 °F and higher (5 °C and higher)

is good

for all purpose use above 40°F, use below 40°F will
cause hard starting.

10W-30

:  

0 to 100 °F (-18 to 38 °C)

is better for

varying temperature conditions. This viscosity
improves cold weather starting, but may increase oil
consumption above 80ºF (27ºC).

Synthetic 5W-30

:  

-20 to 120 °F (-30 to 40 °C)

provides the best protection at all temperatures as
well as improved starting with less oil consumption.

5W-30

40 °F and below (5 °C and below)

is

recommended for winter use, and works best in cold
conditions.

Checking Oil Level

Oil level should be checked prior to each use or at
least every 5 hours of operation. Keep oil level
maintained.

1.

Make sure generator is on a level surface.

2.

Clean area around oil fill and remove oil fill cap.

3.

Verify oil is at the point of overflowing at oil fill
opening.

4.

Replace and tighten oil fill cap.

Adding Engine Oil

1.

Make sure generator is on a level surface.

2.

Check oil level as described in 

Checking Oil

Level

.

3.

If needed, slowly pour oil into oil fill opening to the
point of overflowing at oil fill.

4.

Replace and tighten oil fill cap.

Changing Engine Oil

Change the oil after the first 5 hours of operation.
Change oil every 50 hours thereafter. If you are using
your generator under extremely dirty or dusty
conditions, or in extremely hot weather, change the oil
more often.

KEEP OUT OF REACH OF CHILDREN.
DON’T POLLUTE. CONSERVE
RESOURCES. RETURN USED OIL TO
COLLECTION CENTERS.

Change the oil while the engine is still warm from
running, as follows:

1.

Make sure unit is on a level surface.

2.

Disconnect the spark plug wire from the spark
plug and place the wire where it cannot contact
spark plug.

3.

Clean area around oil drain plug (

A

). The oil drain

plug is located at base of engine, opposite
carburetor (Figure 11).

4.

Remove oil drain plug and drain oil completely
into a suitable container.

5.

Reinstall oil drain plug and tighten securely.
Remove oil fill cap.

6.

Slowly pour oil (about 28 oz.) into oil fill
opening (

B

) to the point of overflowing (

C

) at oil fill

cap (Figure 11). DO NOT overfill.

7.

Reinstall oil fill cap. Finger tighten cap securely.

8.

Wipe up any spilled oil.

Used motor oil has been shown to cause skin cancer in
certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

Avoid prolonged or repeated skin contact with
used motor oil.

CAUTION

Figure 11 — Change Oil

A - Oil Drain Plug
B - Oil Fill Opening
C - Point of Overflowing

B

A

C

Содержание 30235

Страница 1: ...vision 08 10 2006 Failure to read and follow the Operator s Manual and all operating instructions can result in death bodily injury and or property damage WARNING Si no se leen y siguen las indicaciones del Manual del Operario y todas las instrucciones de uso se pueden producir daños materiales lesiones o incluso la muerte ADVERTENCIA ...

Страница 2: ...pendable service This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them Because Briggs Stratton does not necessarily know all the applications this generator could be used for it is important that you read and understand these instructions Keep this manual near the generator for convenient reference This generator...

Страница 3: ...6 Generator Location 6 Features and Controls 7 Receptacles 8 Generator Adapter Cord Set 8 Operation 9 Starting the Engine 9 Connecting Electrical Loads 10 Stopping the Engine 10 Don t Overload Generator 11 Maintenance 12 Oil 13 Service Air Cleaner 15 Service Spark Plug 15 Clean Spark Arrester Screen 15 Engine Air Cooling System 16 Check Valve Clearance 16 Storage 17 Troubleshooting 18 Specificatio...

Страница 4: ...lation intakes or other openings DO NOT operate generator inside any building or enclosure even if doors or windows are open including the generator compartment of a recreational vehicle RV Running generator gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cause nausea fainting or death WARNING The engine exhaust from this product contains chemicals known to...

Страница 5: ...alve OFF Disconnect spark plug wire When storing fuel or equipment with fuel in tank Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death WARNING This generator does not meet U S Co...

Страница 6: ... an e ring D in axle groove 1a E G D B F A C A B Figure 1 Install Wheel Kit A Axle B Wheel C Flat Washer D E Ring E Support Leg F M8 x 16 mm Capscrews G Hex Nuts Equipment Description Read this manual carefully and become familiar with your generator Know its applications its limitations and any hazards involved The generator is an engine driven revolving field alternating current AC generator It ...

Страница 7: ...ine is EM Engine Modifications 1 Clean area around fuel fill cap remove cap 2 Slowly add unleaded gasoline A to fuel tank B Be careful not to overfill Allow at least 1 5 4 cm of tank space C for fuel expansion as shown in Figure 2 3 Install fuel cap and let any spilled fuel evaporate before starting engine High Altitude At higher altitudes over 5 000 feet 85 octane 85 AKI 89 RON gasoline is recomm...

Страница 8: ...m any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Figure 3 Prevailing winds and air currents should be taken into consideration when positioning generator When using generator for backup power notify utility company Use approved transfer equipment to isolate generator from electric utility Use a ground fault circuit interrupter GFCI ...

Страница 9: ...ole circuit breaker is provided to protect all the receptacles and generator against electrical overload G Fuel Tank Capacity of five 5 U S gallons 18 9 l H Fuel Valve Used to turn fuel supply on and off to engine I Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area J Oil Fill Add engine oil here K Recoil Starter Used to start the engine L Engi...

Страница 10: ...t Use cord sets that are rated for 125 Volt AC loads at 20 Amps or greater Inspect cord sets before each use Generator Adapter Cord Set The generator comes with a 25 generator adapter cord set designed to provide two sets of 120 Volt 20 Amp outlets from one 120 Volt 20 Amp duplex receptacle Figure 6 The maximum load on each outlet is 20 Amps The maximum total load on both black wire outlets or whi...

Страница 11: ...l level in the crankcase This unit may be equipped with a low oil protection device Figure 8 Choke Lever Figure 7 Fuel Valve A Off Position B On Position DO NOT touch hot surfaces and avoid hot exhaust gases Allow equipment to cool before touching Keep at least 5 ft 152 cm clearance on all sides of generator including overhead Code of Federal Regulation CFR Title 36 Parks Forests and Public Proper...

Страница 12: ...top engine with electrical devices plugged in and turned ON 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Push engine rocker switch to Off position Figure 9 4 Move fuel valve to Off position A Figure 7 See Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OF...

Страница 13: ...ator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattages listed are approximate only Check tool or applian...

Страница 14: ...placement or repair of the emissions control devices and systems may be performed by any non road engine repair establishment or individual See Emissions Control System Warranty in the Warranties section Maintenance Maintenance Schedule Follow the hourly or calendar intervals whichever occurs first More frequent service is required when operating in adverse conditions noted below 1 Change oil afte...

Страница 15: ...s must be kept clean and unobstructed Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris Use a damp cloth to wipe exterior surfaces clean Use a soft bristle brush to loosen caked on dirt or oil Use a vacuum cleaner to pick up loose dirt and debris Oil Oil Recommendations NOTE When adding oil to the engine crankcase use a high quality detergent oi...

Страница 16: ...fill cap Changing Engine Oil Change the oil after the first 5 hours of operation Change oil every 50 hours thereafter If you are using your generator under extremely dirty or dusty conditions or in extremely hot weather change the oil more often KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Change the oil while the engine is still warm from ru...

Страница 17: ...o start easier and run better 1 Clean area around spark plug 2 Remove and inspect spark plug 3 Check electrode gap with wire feeler gauge and reset spark plug gap to recommended gap if necessary see Figure 13 and Specifications 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use the recommended replacement spark plug See Specifications 5 Install spark plug and tighten ...

Страница 18: ...buretor Adjustment The carburetor on this engine is low emission It is equipped with a non adjustable idle mixture valve Top speed has been set at the factory If adjustment is required see an authorized service dealer Figure 15 Air Cooling System A Clean These Areas Figure 14 Service Spark Arrester A Heatshield B Muffler C Spark Arrester Screen DO NOT touch hot surfaces and avoid hot exhaust gases...

Страница 19: ...tain freshness Change Oil While engine is still warm drain oil from crankcase Refill with recommended grade Oil Cylinder Bore Remove spark plug and pour about 1 2 ounce 15 ml of clean engine oil into the cylinder Install spark plug and pull starter handle slowly to distribute oil Other Storage Tips 1 DO NOT store fuel from one season to another unless it has been treated as described in Long Term ...

Страница 20: ... set to Off 2 Fuel Valve is in Off position 3 Dirty air cleaner 4 Out of fuel 5 Stale fuel 6 Spark plug wire not connected to spark plug 7 Bad spark plug 8 Water in fuel 9 Flooded 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to On 2 Turn fuel valve to Open position 3 Clean or replace air cleaner 4 Fill fuel tank 5 Drain fuel tank...

Страница 21: ... Capacity 5 U S gallons Shipping Weight 170 lbs Engine Specifications Gross Horsepower 10 at 3600 rpm Bore 3 120 in 79 23 mm Stroke 2 438 in 61 67 mm Displacement 18 64 cu in 305 cc Spark Plug Type Champion RC12YC or Equivalent Set Gap To 0 030 in 0 76 mm Armature Air Gap 0 010 0 014 in 0 25 0 36 mm Valve clearance with valve springs installed and piston 1 4 in 6 mm past top dead center of compres...

Страница 22: ... road engine but B S cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance As the small off road engine owner you should however be aware that B S may deny you warranty coverage if your small off road engine or a part has failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for pre...

Страница 23: ... California Air Resources Board CARB Tier 2 Emission Standards must display information regarding the Emissions Durability Period and Air Index The engine manufacturer makes this information available to the consumer on emission labels The Emissions Durability Period describes the number of hours of actual running time for which the engine is certified to be emissions compliant assuming proper mai...

Страница 24: ...anty repair and apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty service would not apply if equipment damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper installati...

Страница 25: ...This page reserved ...

Страница 26: ...de buen funcionamiento Este manual contiene información sobre seguridad para hacerle consciente de los riesgos asociados a los generadores y mostrarle cómo evitarlos Briggs Stratton no conoce necesariamente todas las aplicaciones que este generador puede tener por ello es importante que lea y entienda estas instrucciones Conserve este manual para futuras consultas Este generador requiere montaje f...

Страница 27: ...nerador 6 Controles y características 7 Tomas eléctricas 8 Juego de cables del adaptador del generador 8 Operando 9 Encienda el motor 9 Conexión de cargas eléctricas 10 Parada del motor 10 No sobrecargar el generador 11 Mantenimiento 12 Aceite 13 Servicio del depurador de aire 15 Servicio del bujía 15 Limpie la pantalla apagachispas 15 Sistema de refrigeración de aire 16 Comprobación de holgura de...

Страница 28: ... notifique a la compañía de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad eléctrica Use un interruptor para la falla del circuito de tierra GFCI en cualquier área bastante húmeda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o receptáculos NO use un generador con cables eléctricos q...

Страница 29: ...lica obliga a instalar una pantalla apagachispas en los equipos con motor de combustión interno y a mantenerla en buenas condiciones de funcionamiento conforme a la norma 5100 1C o posterior del Servicio Forestal de la USDA En el Estado de California la ley exige el uso de una pantalla apagachispas Sección 4442 del Código de Recursos Públicos de California En otros estados puede haber leyes simila...

Страница 30: ... 4115 Si llamar para la ayuda tiene por favor el modelo la revisión y el número de serie de etiqueta de datos disponible Consulte la ubicación en la sección Controles y características Desembalaje del generador 1 Coloque la caja de cartón en una superficie rígida y plana 2 Abra completamente la caja de cartón cortando cada una de sus esquinas de arriba abajo 3 Saque todo el contenido de la caja de...

Страница 31: ... área alrededor de la tapa de llenado del combustible retire la tapa 2 Añada lentamente gasolina sin plomo A al depósito de combustible B NO añada combustible en exceso Deje aproximadamente 4 cm 1 5 de espacio en el depósito C para permitir la expansión del combustible como se muestra en la Figura 2 3 Instale la tapa del tanque de combustible y la espera para algún combustible rociado para evapora...

Страница 32: ...Tenga en cuenta los vientos y las corriente de aire preponderantes cuando elija la ubicación del generador El usar un generador en espacios interiores le causará la muerte en unos minutos Los gases de combustión contienen monóxido de carbono un gas venenoso que usted no puede ver ni oler NUNCA lo use dentro del hogar ni en lugares parcialmente cerrados tales com garajes SOLO úselo al aire libre y ...

Страница 33: ...a medida que penetra en el motor D Palanca Estranguladora Usada cuando se está dando arranque a un motor frío E Etiqueta de Datos Proporciona el modelo revisión y el número de serie de generador Tenga por favor estos prontamente disponible cuándo llamar para la ayuda F Disyuntor Basculante Un disyuntor basculante que protege el generador contra sobrecargas eléctricas G Tanque del Combustible El ta...

Страница 34: ...es que son calificados para cargas de 125 Voltios AC a 20 Amps o mayores Juego de cables del adaptador del generador El generador está equipado con un Juego de Cables del Adaptador del Generador de 25 pies diseñado para un circuito neutro a tierra de 120 voltios 20 Amperios Figura 6 La carga máxima en cada tomacorriente es de 20 Amperios La carga máxima total tanto en el tomacorriente de cable ama...

Страница 35: ...vel de aceite En caso afirmativo el nivel del aceite debe ser adecuado para que el motor arranque NO toque las superficies calientes y evite los gases del escape a alta temperatura Permita que el equipo se enfríe antes de tocarlo Deje un espacio mínimo de 152 cm 5 pies alrededor del generador incluida la parte superior El Código de Normativa Federal CFR Título 36 Parques Bosques y Propiedad Públic...

Страница 36: ...endidos 2 Deje que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador 3 Sitúe el interruptor On Off en la posición Off 4 Gire la válvula de combustible blanca hasta la posición Off Vea No sobrecargue generador Encienda su generador y deje que el motor se estabilice antes de conectar las cargas eléctricas Conecte las cargas eléctrica...

Страница 37: ...y encienda la próxima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA añada cargas que sobrepasen la capacidad del generador Tenga especial cuidado en contar con las cargas adicionales en la capacidad del generador como se describe arriba La potencia que aparece en la lista es aproximada Compruebe la herramienta o apa...

Страница 38: ...igencia del operador Para recibir el valor completo de la garantía el operador deberá mantener el generador de la forma descrita en este manual Se deberán llevar a cabo algunos ajustes periódicamente para mantener correctamente su generador Todos los ajustes de la sección Servicio y Ajustes de este manual deberán ser hechos por lo menos una vez en cada estación Cumpla con los requisitos de la tabl...

Страница 39: ...s y despejadas Mantenga limpios los componentes del generador para reducir el riesgo de sobrecalentamiento e ignición de los residuos acumulados Utilice un trapo húmedo para limpiar las superficies exteriores Puede usar un cepillo de cerdas suaves para retirar la suciedad endurecida aceite etc Puede usar una máquina aspiradora para eliminar suciedad y residuos sueltos Aceite Recomendaciones sobre ...

Страница 40: ... firmemente Cambio de Aceite del Motor Cambie el aceite después de las primeras 5 horas de operación Cambie el aceite cada 50 horas de ese momento en adelante Si está utilizando su generador bajo condiciones de extrema suciedad o polvo o en un clima demasiado caliente haga el cambio de aceite más frecuentemente MANTENER FUERA DEL ALCANCE DE LOS NIÑOS NO CONTAMINE CONSERVE LOS RECURSOS DEPOSITE EL ...

Страница 41: ...arrancar más fácilmente y funcionar mejor 1 Limpie la zona de alrededor de la bujía 2 Retire e inspeccione la bujía 3 Compruebe la separación del electrodo con un calibrador de alambre y ajuste el espacio de la bujía a la medida recomendada si fuera necesario véase la Figura 13 y Especificaciones 4 Cambie la bujía si los electrodos están picados o quemados o si la porcelana está agrietada Utilice ...

Страница 42: ... emisión Está equipado con una válvula de mezcla de ralentí no ajustable y en algunos casos con ralentí regulado Los niveles de ralentí regulado y velocidad máxima se ajustan en la fábrica Si es necesario modificarlos acuda a un distribuidor de servicio Figura 15 Sistema de Refrigeración de Aire A Limpie estas Areas Figura 14 Servicio del Pantalla Apagachispas A Protección del Silenciador B Silenc...

Страница 43: ...eite Con el motor todavía caliente drene el aceite de la caja del cigüeñal Vuelva a llenarlo con el grado de aceite recomendado Aceite el Diámetro Interior del Cilindro Quite la bujía y vierta aproximadamente 15 ml 1 2 onza de aceite de motor limpio en el interior del cilindro Coloque la bujía y arranque lentamente para distribuir el aceite Otras Sugerencias Para el Almacenamiento 1 NO guarde comb...

Страница 44: ... aire sucio 4 Sin gasolina 5 Gasolina vieja 6 El cable de la bujía no está en malas la bujía 7 Bujía defectuosa 8 Agua en la gasolina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 11 La válvula de entrada está atascada está cerrada 12 El motor ha perdido compresión 1 Gire la válvula del combustible a la posición On 2 Coloque del interruptor On Off en On 3 Limpie o reemplace el depurado...

Страница 45: ...dad de Gasolina 5 galones americanos Peso que Embarca 170 lbs Especificaciones del Motor Potencia bruta 10 0 a 3600 rpm Diámetro de camisa 79 23 mm 3 120 pulgadas Carrera 61 67 mm 2 438 pulgadas Desplazamiento 305 cc 18 64 pulgadas Bujía Tipo Briggs Stratton 491055 Calibrar Separación a 0 030 pulgadas 0 76mm Entrehierro del inducido 0 25 0 36 mm 0 010 0 014 pulgadas Holgura de la válvula con muell...

Страница 46: ...acturas relativas al mantenimiento del motor pero B S no puede denegar la garantía basándose únicamente en la falta de facturas o en la imposibilidad por parte del propietario de asegurar la correcta realización de todas las operaciones de mantenimiento Como propietario del pequeño motor para máquinas de servicio debe ser consciente de que B S puede denegar la cobertura de la garantía si el motor ...

Страница 47: ...alifornia Air Resources Board CARB deben mostrar información sobre el período de durabilidad de las emisiones y el índice de aire El fabricante del motor ofrece esta información al consumidor mediante etiquetas de emisiones El período de durabilidad de las emisiones indica el número de horas durante las cuales el motor puede funcionar cumpliendo las normas sobre emisiones siempre que se realicen l...

Страница 48: ...rvicio público y los equipos sanitarios destinados al mantenimiento de las constantes vitales Esta garantía excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WI EE UU Segundo año sólo piezas POLÍTICA DE GARANTÍA PARA EL PROPIETARIO DE UN GENERADOR PORTÁTIL BRIGGS STRATTON ...

Отзывы: