Generator Location

The actual physical location of your backup generator has a
direct affect on the amount of wiring required to control
and connect your generator.

NOTE: Specific location guidelines are discussed in the
Installation Manual. Acquaint yourself with that information
and confer with your installer. Be sure to ask how your site
might affect installation costs and compliance with local
codes and standards.

Generator Clearances

The generator must be a minimum of 3 ft. (92 cm) from
combustible material (NFPA 37). Leave at least 3 ft. (92 cm)
all around for access to the generator.

The unit’s exhaust port must be at least 5 ft. (152 cm) from
any building opening (window, door, vent etc.), and the
exhaust must not be able to accumulate in any occupied
area (Figure 1).

Figure 2 identifies system components and shows typical
installation details.Variations to this illustration are related
to code issues and materials.

Figure 1 — Home Generator System Clearances

Exhaust port must be

5 ft (152 cm) minimum

distance from building

openings

Exhaust

Port

Figure 2 — Typical Completed Semi-Automatic Transfer Switch Installation

Utility Power Line

Utility Meter

Connection Box

Electrical
Load
Center

Utility Power

Semi-Automatic
Transfer Switch

Содержание 1678

Страница 1: ...da es justa un momento lejos Vous avez des questions Vous n avez pas besoin d aller loin pour trouver de l aide Call Home Standby Helpline Llamada L nea Directa de Reserva de Hogar Appelez Ligne Direc...

Страница 2: ...symbol indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The engine exhaust from this product contains chemicals known t...

Страница 3: ...id and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER Do not touch hot surfaces Allow equipment to cool before touching Running engines produce heat Temperatur...

Страница 4: ...formed choices and communicate effectively with your installation contractor s Read and understand the Owner Orientation Section of this manual BEFORE contracting or starting your HGS installation To...

Страница 5: ...92 cm from combustible material NFPA 37 Leave at least 3 ft 92 cm all around for access to the generator The unit s exhaust port must be at least 5 ft 152 cm from any building opening window door vent...

Страница 6: ...hts can be taken from light bulbs The rated wattage of tools appliances and motors can usually be found on a data plate or decal affixed to the device If the appliance tool or motor does not give watt...

Страница 7: ...t the power transfer system components and conduit 3 Conduit fittings wire nuts and insulated copper wire for connecting the semi automatic transfer switch to the outside connection box Delivery Inspe...

Страница 8: ...n valve facing outward 3B Place one end of the needle nose pliers on the bottom of the axle and the other end of the pliers on top of the e ring Seat the e ring by pressing the pliers closed 4 Slide t...

Страница 9: ...fill fuel tank when engine is running or hot Allow unit to cool for two minutes before refueling Do Not light a cigarette or smoke when filling the fuel tank WARNING Do Not overfill the fuel tank Alwa...

Страница 10: ...of dirt and dust that gets in the engine Choke Lever Used when starting a cold engine Circuit Breakers AC Each receptacle is provided with a circuit breaker to protect the generator against electrical...

Страница 11: ...rovided Figure 7 to make the grounding attachment Connecting a No 12 AWG American Wire Gauge stranded copper wire to the grounding wing nut and to an earth driven copper or brass grounding rod electro...

Страница 12: ...o Not connect 3 phase loads to the generator Do Not connect 50 Hz loads to the generator DO NOT OVERLOAD THE GENERATOR When not used with the semi automatic transfer switch add up the rated watts or a...

Страница 13: ...rator is running How to Use the Battery Charger Use the battery float charger jack to keep the starting battery charged and ready for use Battery charging should be done in a dry location such as insi...

Страница 14: ...the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device ope...

Страница 15: ...enerator control panel Start the generator using instructions given in the section Operating the Generator on page 11 5 Close the generators main circuit breaker 6 After a ten second delay the transfe...

Страница 16: ...the house connector box see Figure 15 4 At the generator connect the other end of the power cord to the generator see Figure 16 Make sure the circuit breaker on the generator is open OFF 5 Start the g...

Страница 17: ...ON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry e...

Страница 18: ...ge See engine owner s manual for instructions Other Storage Tips To prevent gum from forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh gaso...

Страница 19: ...gasoline 9 Overchoking 10 Low oil level 11 Excessively rich fuel mixture 12 Intake valve stuck open or closed 13 Engine has lost compression 14 Failed battery 1 Set switch to On 2 Turn fuel valve to...

Страница 20: ...20 Briggs Stratton Power Products Home Generator System Owners Manual NOTES...

Отзывы: