background image

Not for 

Reproduction

 31

Only authorized service dealers may perform warranty repairs. Most 
warranty repairs are handled routinely, but sometimes requests for warranty 
service may not be appropriate. For example, warranty service would not 
apply if equipment damage occurred because of misuse, lack of routine 
maintenance, and shipping, handling, warehousing or improper installation. 
Similarly, warranty coverage will not be provided if the manufacturing date 
or serial number(s) on the equipment has been removed or the equipment 
has been altered or modified. During the warranty period, the authorized 
service dealer, at its option, will repair or replace any part that, upon 
examination, is found to be defective under normal use and service. This 
warranty will not cover the following repairs due to:
  1.  Normal Wear and Maintenance: Outdoor Power Equipment and 

engines, like all mechanical devices, need periodic parts and service 
to perform well. This warranty does not cover repair when normal 
use has exhausted the life of a part or the equipment. Typical wear 
items include engine oil, oil gauges, o-rings, filters, fuses, spark 
plugs, anti-freeze, starting batteries, etc. Normal maintenance 
such as: adjustments, loose or leaking clamps or connections, 
installation or start-up operations, fuel system cleaning and 
obstruction due to contamination.

  2.  Installation, Operation, Maintenance and Storage: This warranty 

does not apply to equipment or parts that have been subjected to 
improper or unauthorized installation or alteration and modification, 
abuse, misuse, negligence, accident, overloading, overspeeding, 
improper maintenance, repair or storage so as to adversely affect 
its performance and reliability.

  3.  Enclosure is not warranted for surface rust or corrosion or 

complete rust-through that may result due to improper installation, 
damage to painted surfaces that compromise the paint’s corrosion 
prevention properties, or if the unit is installed in environments that 
expose the generator to high levels of corrosive agents.

This warranty will not cover equipment used in:
  1.  Equipment used for prime power. For purposes of this warranty, 

Prime Power is defined as an application in which the generator is a 
source of power where no electrical power service is available from 
the UTILITY POWER GRID. If no UTILITY power is available, the 
generator is considered the prime power source.

  2.  Used, reconditioned, and demonstration equipment, or rental 

equipment. Rental use means any use of this product in a 
temporary or semi-permanently installed rental application. 
Once equipment has experienced rental use, it shall thereafter be 
considered rental equipment for purposes of this warranty.

  3.  Equipment used in life support applications.
  4.  Failures caused by any force majeure event or external force beyond 

the manufacturer’s control or Act of God such as, but not limited 
to freezing, theft, fire, collision, wars or riots, hail, water or flood 
damage, tornados, hurricanes, or terrorist acts.

  5.  Use of non-original parts and non-authorized installation or 

warranty service by unauthorized dealers.

  6.  Rodent and/or insect infestations.

This warranty also does not include:
  1.  Any and all expenses incurred investigating performance complaints 

unless defective Briggs & Stratton materials and/or workmanship 
were the direct cause of the problem.

  2.  The cost of rental equipment used while warranty repairs are being 

performed (i.e., generators, pumps, etc.)

Warranty terms effective May 1, 2014. 

ABOUT YOUR WARRANTY

80010905, Rev. A, 1 May 2014

Содержание 040351

Страница 1: ...N o t f o r R e p r o d u c t i o n Generator Systems Operator s Manual Generator System...

Страница 2: ...nerator requires professional installation before use Refer to the separate installation manual for full information Your installer should follow the instructions completely Where to Find Us You never...

Страница 3: ...Sequence 19 Setting Exercise Timer 20 Maintenance 21 Servicing the System 21 Service Code Detection System 21 Maintenance Schedule 23 Generator Maintenance 23 Engine Maintenance 24 Adjust Valve Lash...

Страница 4: ...ziness vomiting confusion seizures nausea or fainting Operate this product ONLY outdoors in an area that will not accumulate deadly exhaust gas Keep exhaust gas away from any windows doors ventilation...

Страница 5: ...ways set the generator s system switch to OFF remove the service disconnect from the disconnect box AND remove the 15 Amp fuse BEFORE working on the equipment WARNING Propane and Natural Gas are extre...

Страница 6: ...d on generator DO NOT tamper with governed speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT modify generator in any way WARNING Exhaust heat gases cou...

Страница 7: ...lp you make informed choices and communicate effectively with your installation contractor s read and understand Owner Orientation in this manual before contracting or starting your generator installa...

Страница 8: ...of 2 5 and minimum propane content of 90 Natural gas rating will depend on specific fuel but typical derates are between 10 to 20 off the LP gas rating Natural gas or LP engines are certified to opera...

Страница 9: ...positioning generator See the installation manual for full details on safe generator location WARNING Running engine gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxi...

Страница 10: ...and your installer for claim procedures Missing or damaged parts are not warranted The home generator system is supplied with Oil 5W30 Synthetic Flexible steel fuel line Installation and start up man...

Страница 11: ...h most residential codes C Alternator An electrical machine that generates an alternating current D Spark Plug A device in the cylinder head of the engine that ignites the fuel mixture by means of an...

Страница 12: ...recleaner to protect engine by filtering dust and debris out of intake air F Control Panel Used for various test operation and maintenance functions See System Control Panel G Circuit Breaker Protects...

Страница 13: ...rator is equipped with an enclosure that has several access panels as shown A Front Panel that is used to access Battery Compartment Engine Oil Drain Hose Engine Oil Filter Engine Valve Cover Spark Pl...

Страница 14: ...the unit 2 Carefully lift and remove roof from unit To remove front panel 1 Remove the two screws B that secure the panel to the unit 2 Lift and flex panel outward and off base Use caution not to dama...

Страница 15: ...he next utility outage OFF Turns off running generator prevents unit from starting and resets any detected service codes OFF must be pressed and held for more than 5 seconds in order to reset service...

Страница 16: ...PUT UNIT INTO AUTOMATIC MODE IF A UTILITY POWER OUTAGE IS SENSED THE SYSTEM WILL START THE GENERATOR WHEN UTILITY POWER IS RESTORED AUTO LETS THE ENGINE STABILIZE INTERNAL TEMPERATURES SHUTS OFF THE G...

Страница 17: ...ercise Cycle was also set at the factory The default exercise cycle occurs on Tuesdays at 2 00 P M Central Standard Time To update or change these settings follow the steps below SET DATE If set to OF...

Страница 18: ...MENU button The following will scroll across the digital display and then move to the next item Run time Date Time Exercise Cycle date and start time The user can press the LEFT ARROW or RIGHT ARROW a...

Страница 19: ...ops below about 70 percent of the nominal supply voltage the sensor energizes a 3 second timer The timer is used to sense brown outs Once the timer has expired the engine will crank and start Utility...

Страница 20: ...to the SET EXERCISE prompt and hit the OK button NOTICE Items will flash until they are selected SELECT DAY Use the left or right arrow to toggle through the days of the week Once the day is selected...

Страница 21: ...enerator to service by pressing and holding the control board AUTO button and installing the 15 Amp fuse if removed Low Battery Voltage This service code is indicated by Low Battery Voltage scrolling...

Страница 22: ...aller or an authorized dealer Engine Overspeed This service code is indicated by Engine Overspeed scrolling across the digital display To resolve the problem contact your installer or an authorized de...

Страница 23: ...t be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air louvers on the enclosure must not become clogged with snow leaves or any other foreign material To prevent generator da...

Страница 24: ...DO NOT exceed 13 7 volts when charging NOTICE DO NOT use a battery booster to quick charge a low battery 5 Connect negative battery cable to negative battery terminal indicated by NEGATIVE NEG or 6 E...

Страница 25: ...AE 30 will result in hard starting Above 80 F 27 C the use of 10W30 may cause increased oil consumption Check oil level more frequently Checking Adding Engine Oil 1 Open roof to access dipstick and oi...

Страница 26: ...re installing a new oil filter lightly lubricate the oil filter gasket with fresh clean oil 9 Install the oil filter by hand until the gasket contacts the oil filter adapter then tighten the oil filte...

Страница 27: ...tion and potential damage from dirt leaves rodents spider webs insects etc and remove Service Spark Plugs Changing the spark plugs will help your engine to start easier and run better 1 Clean area aro...

Страница 28: ...fuel valve s check propane tank 3 Replace battery 4 Clean or replace air filter Engine shuts down during operation 1 Fuel supply turned off or depleted 2 Control board digital display shows a service...

Страница 29: ...s repaired or replaced under this warranty the new part will be warranted only for the remaining warranty period If a warrantable component scheduled for maintenance fails prior to its first scheduled...

Страница 30: ...emailing or writing to salesenquires briggsandstratton com au Briggs Stratton Australia Pty Ltd 1 Moorebank Avenue NSW Australia 2170 BRIGGS STRATTON POWER PRODUCTS GROUP LLC STANDBY GENERATOR OWNER...

Страница 31: ...ersely affect its performance and reliability 3 Enclosure is not warranted for surface rust or corrosion or complete rust through that may result due to improper installation damage to painted surface...

Страница 32: ...N o t f o r R e p r o d u c t i o n 32 This page intentionally left blank...

Страница 33: ...d AC Voltage 120 240 Volts Phase Single phase Rated Frequency 60 Hertz Generator Breaker 35 Amp Normal Operating Range 20 F 28 8 C to 104 F 40 C Output Sound Level 76 8 dB A at 23 ft 7 m at normal loa...