background image

Not for 

Reproduction

7

Operation

Operation

Step 1: Safe Location

Before starting the portable generator there are two equally 

important safety concerns regarding carbon monoxide  

poisoning and fire that must be addressed.

Operation Location to Reduce the Risk of  

Carbon Monoxide Poisoning

The engine exhaust of all fossil fuel burning equipment, 

such as a portable generator, contains carbon monoxide, 

a poisonous gas that could kill you in minutes. You cannot 

smell it, see it, or taste it. Even if you do not smell exhaust 

fumes, you could still be exposed to carbon monoxide gas. 
By law it is required in many states to have a carbon 

monoxide alarm in operating condition in your home. 

A carbon monoxide alarm is an electronic device that 

detects hazardous levels of carbon monoxide. When there 

is a buildup of carbon monoxide, the alarm will alert the 

occupants by flashing visual indicator light and alarm. 

Smoke alarms cannot detect carbon monoxide gas.

WARNING! 

  Engine exhaust contains carbon 

monoxide, a poisonous gas that could kill you in 

minutes. You cannot smell it, see it, or taste it. 

Even if you do not smell exhaust fumes, you could still be 

exposed to carbon monoxide gas. 

•  Operate this product only outdoors far away from 

windows, doors and vents to reduce the risk of carbon 

monoxide gas from accumulating and potentially being 

drawn towards occupied spaces. 

•  Install battery-operated carbon monoxide alarms or 

plug-in carbon monoxide alarms with battery back-up 

according to the manufacturer’s instructions. Smoke 

alarms cannot detect carbon monoxide gas. 

•  Do not run this product inside homes, garages, 

basements, crawlspaces, sheds, or other partially-

enclosed spaces even if  using fans or opening doors 

and windows for ventilation. Carbon monoxide can 

quickly build up in these spaces and can linger for 

hours, even after this product has shut off. 

•  Always place this product downwind and point the 

engine exhaust away from occupied spaces. 

If you start to feel sick, dizzy, or weak while using this 

product, get to fresh air right away. See a doctor. You may 

have carbon monoxide poisoning.

Carbon monoxide alarm

Install carbon monoxide alarms inside 
your home. Without working carbon
monoxide alarms, you will not realize
you are getting sick and dying from
carbon monoxide poisoning

.

CARBON MONOXIDE ALARM(S)

USE OUTDOORS - AVOID CARBON MONOXIDE POISONING 

point away

from home

MUFFLER

Содержание 030694-00

Страница 1: ...Number ______________________________ Revision ___________________________________ Serial Number _______________________________ Date Purchased _____________________________ Copyright 2017 Briggs Str...

Страница 2: ...ighting appliances tools and motor loads The voltage regulator within the generator is designed to automatically maintain output voltage level The portable generator produces power that can be used fo...

Страница 3: ...aving jurisdiction for grounding requirements in your area Identification Label Provides model and serial number of generator Oil Drain Plug Drain engine oil here Oil Fill Cap Dipstick Check and add e...

Страница 4: ...ructions 3 Extension cords running directly into the home increase your risk of carbon monoxide poisoning through openings Install carbon monoxide alarm s 4 Before your next home power outage install...

Страница 5: ...s switch to ON I before starting engine Set switch to OFF 0 to shut off engine Low Oil Shutdown This unit is equipped with a low oil protection device Oil must be at proper level for engine to run If...

Страница 6: ...N o t f o r R e p r o d u c t i o n 6 BRIGGSandSTRATTON com au Features and Controls Features and Controls...

Страница 7: ...te it Even if you do not smell exhaust fumes you could still be exposed to carbon monoxide gas Operate this product only outdoors far away from windows doors and vents to reduce the risk of carbon mon...

Страница 8: ...least 1 5 m 5 ft from any structure overhang trees windows doors any wall opening shrubs or vegetation over 30 5 cm 12 in in height Do not place portable generator under a deck or other type of struct...

Страница 9: ...p This allows adequate space for fuel expansion 7 Install fuel cap and let any spilled fuel evaporate before starting engine High Altitude At altitudes over 1524 m 5 000 ft a minimum 85 octane 85 AKI...

Страница 10: ...Total running watts 2355 Highest Starting Watts 2000 Total generator watts required 4355 3 Estimate the Starting Watts you will need Because not all motors start at the same time total Starting Watts...

Страница 11: ...ulated debris Keep area around muffler free from any debris Use a soft bristle brush to loosen caked on dirt or oil Use a damp cloth to wipe exterior surfaces clean NOTICE Improper treatment of genera...

Страница 12: ...pstick 4 If needed slowly pour oil into oil fill opening to the point of overflowing 5 Replace and tighten dipstick NOTICE Do not attempt to crank or start engine before it has been properly serviced...

Страница 13: ...recommended replacement spark plug See Common Service Parts 4 Check electrode gap with wire feeler gauge and reset spark plug gap to recommended gap if necessary see Specifications 5 Install spark pl...

Страница 14: ...it must be drained into an approved container Run the engine until it stops from lack of fuel The use of a fuel stabilizer in the storage container is recommended to maintain freshness WARNING Fuel an...

Страница 15: ...0 030 in Fuel Capacity 11 4 Liters 3 U S Gallons Oil Capacity 0 6 Liters 20 Ounces Sound Pressure 7 m 71 dBA Power Ratings The gross power rating for individual gasoline engine models is labeled in a...

Страница 16: ...ry if equipped 3 months consumer use none commercial use In Australia Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refu...