5
General Information
3. 0 Te c h n i c a l In f o r m a t i o n
3.1 Appliance Certification
This appliance was listed by QAI Laboratories Inc to the following USA and Canadian gas appliance standards.
- ANSI Z21.88-2019 / CSA 2.33-2019 Vented Gas Fireplace Heaters
- CSA-2.17-2017, Gas-Fired Appliances for Use at High Altitudes
- CSA P.4.1-15 testing method for measuring annual fireplace efficiency.
- CSA C22.2 No.3 - M1998(R.2014) - Electrical Features of Fuel-Burning Equipment
The listing label is attached to the appliance on the bottom right side of the appliance.
A copy is shown on
Se c t i o n 4 . 0
.
C o m m o n w e a l t h o f Ma s s a c h u s e t t s
: This appliance has been manufactured in accordance with Massachusetts code 248 CMR 5.00.
Approval Code: G1-0617-596. (https://licensing.reg.state.ma.us/pubLic/pl_products/pb_pre_form.asp).
Please contact
Ar c h g a r d In d u s t r i e s Lt d
., if you have any questions regarding the certification of this appliance.
3. 2 In s t a l l a t i o n C o d e s
This appliance must be installed by a qualified gas appliance installer. The installation must conform with the local codes or, in
the absence of local codes, with the current National Fuel Gas Code ANSI Z223.1/ NFPA 54 in the US, or Installation Code CAN/
CGA-B149.1 in Canada. Electrical connections and grounding must conform with local code, or current National Electrical code ANSI/
NFPA No. 70-1987 in the US, and in Canada the current Canadian Electrical Code CSA C22.1.
We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the
Na t i o n a l F i r e p l a c e In s t i t u t e ® ( NF I) a s NF I Ga s Sp e c i a l i s t s .
3.3 Specifications
Na t u r a l Ga s ( NG)
Pr o p a n e ( LP)
Ma n i f o l d Pr e s s u r e
1.1 - 3.8 in. W.C. (0.3 - 0.9 kPa)
2.9 - 11.0 in. W.C. (0.7 - 2.7 kPa)
Mi n . Su p p l y Pr e s s u r e
Ma x Su p p l y Pr e s s u r e
5.0 in. W.C. (1.2 kPa)
14.0 in. W.C. (3.5 kPa)
12.0 in. W.C. (2.98 kPa)
14.0 in. W.C. (3.5 kPa)
Orifice Size
#35 DMS (2.794 mm dia)
#52 DMS (1.613 mm dia)
In p u t Ra t i n g
16,000 - 31,000 BTU/hr (4.4- 9.1kW)
P.4 Fireplace Efficiency
( F E)
75.48%
El e c t r i c a l Ra t i n g
120 VAC, 60Hz less than 2 A.
Ga s C o n t r o l
SIT 885 Proflame II Dynamic Start Advantage with Continuous Pilot on Demand
Al t i t u d e
0 - 4,500 ft. (0 - 1372 M)
Pr i m a r y Ai r Op e n i n g
1/4” (6 mm) OPEN
FULLY OPEN
3. 4 Hi g h Al t i t u d e In s t a l l a t i o n
When installing this appliance beyond 4500 ft. (1372 M) above sea level, the appliance must be properly derated and installed
according to local codes, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or
Installation Code, CAN/CGA-B149.1, in Canada.