SW1 = Antenna Power - Set power manually select 1 = Min to F = Max

Min.

Power

Max. 

Power

SW1

1.  Mount Masking Zone Antenna as close as possible to the location where 

you require the quiet zone.

2.  Set up Detection Zone with Detectio range as required (see ZoneSafe QSG 

for further instructions if needed).

3.  Place a tag in the closest position within vehicle detection area inside the 

quiet zone. The system will start alarming and the tag will vibrate.

4.  Position the Detection Zone in the closest proximity to the quiet zone
5.  Slowly adjust the quiet zone range using SW1 on the masking Antenna 

until tag stops sounding the alarm as per below. Your quiet zone range is 

now set.

Find the SW1 Dial located inside the  

Masking Zone Antenna.

The SW1 dial has a number and 

letter range adjusting between 1 (min)  

and F (max). You can adjust the dial 

between these figures to adjust the 

power of the quiet zone.

Setting Up The Masking Zone Antenna

VIEW A-A

SCALE 1 : 1

A

1

1

2

3

4

5

6

A

B

C

D

E

F

REV:

DATE:

CHANGE:

STATUS:

 

CUSTOMER:

SCALE @

DRAWN BY:

REV:

DRAWING NO:

TITLE:

UNCONTROLLED

 

 

 

SHEET

 

 

A0

THIS DRAWING IS THE PROPERTY OF AND MAY EMBODY PROPRIETARY INFORMATION

OWNED BY AVONWOOD DEVELOPMENTS LTD. IT IS PROVIDED UNDER A CONFIDENTIAL

RELATIONSHIP FOR A SPECIFIC PURPOSE. THE RECIPIENT AGREES TO USE IT ONLY FOR

SUCH PURPOSE.

 

AS INDICATED IN ISO 2768-1    

 TOLERANCE CLASS

LINEAR =  f

ANGULAR = f

BROKEN EDGES = f

1 / 1

UNLESS OTHERWISE STATED

73.43

20.43

8.

50

Pin 1 - 0V

CONN2

Pin 2 - +V

Wiring

The Masking Zone Antenna is wired in via CONN2 which is located inside the  

unit as shown below. To gain access to the inside of the Masking Zone Antenna, 

unscrew the six M4 40mm screws (located on the front of the box) with a  

hex drive).

The DC OUT supply is wired into Pin 1 (OU) and Pin 2 (+V). 

The +V wire can be distinguished by the white line dotted along the outside of 

the wire as shown below.

24v DC 

OUT

+V

0V

5

Power

Cable

Adjusting The Masking Zone Antenna Range

To Masking 

Zone Antenna

Connection

+V

230V

AC IN

To Fused AC Mains Supply

Masking Zone 

Antenna

Forklift

Quiet Zone

(Yellow Hatch)

Detection 

Zone

(Red Zone)

Detection Zone

Masked By

Quiet Zone

Worker Undetected by 

system

(because he is in the Quiet 

Zone which masks the 

Detection Zone) 

 

Worker detected

by system

Wall

Walkway

Warehouse

Floor

Worker Undetected 

by system

Typical Example of a Working Masking Zone Antenna system

Up to 9m

Up to 9m

AC IN

DC OUT

5