LS-60 (4851)-Installation&Operation Guide - v0.3 ENG draft

.docx

 

3.2 

Sequence for Displaying or Programming 

1. Power up the unit while vehicle is stationary (no speed pulse present). 
2. 

Hold

 the pink wire to ground (0V, e. g. to black wire). 

3. Immediately release the PINK wire from ground after 3 RED/GREEN light flash cycles (within 

less than 2secs). 

4. There are then two modes available: 

4.1. Enter 

Display Mode

 - Used to view current stored speed threshold setting: 

(1)  After a 

single

 GREEN light flash, immediately touch the PINK wire to ground (within 

less than 2secs) then 3 RED/GREEN light flash cycles (Within 2 Seconds) 

(2)  The GREEN light will start to flash. Count the GREEN light flashes and refer to the 

table above for the set speed threshold. 

(3)  Followed by 5 fast GREEN light flashes to confirm the end of the 

Display Mode

(4)  Return to 

Normal Operation

 with constant GREEN light. 

4.2. Enter 

Program Mode

 - Used to change speed threshold setting: 

(1)  After a 

double

 GREEN light flash, immediately touch the PINK wire to ground (within 

less than 2secs). 

(2)  The GREEN light will start to flash up to 10 times. Immediately touch the PINK wire to 

ground once the count has reached the required number corresponding to the desired 
speed threshold, see above table. 

(3)  Followed by 5 fast GREEN light flashes to confirm the end of the Program Mode. 
(4) 

Normal Operation

 is resumed with constant GREEN light. 

(5)  It is recommended to check if the selected speed setting is correct via the 

Display 

Mode

3.3 

Further Notes on 

Display

 or 

Program

 Mode 

1.  If an input signal (speed pulse) is detected on the GREEN wire (Speed Pulse Input) the 

sequence for Displaying or Programming 

cannot

 be entered. The vehicle must be stationary. 

2.  If the correct sequence is not followed for 

Display 

or 

Program Mode

 the RED light will flash 5 

times to indicate an error and 

Normal Operation

 will resume with previous setting. 

3.  After either the 

Display

 or 

Program Modes

 have finished, the PINK wire must be 

disconnected from ground for at least 1sec before next sequence can be started again. 

Specifications 

Speed range 

0 to 60mph / 100kmp 

Speed pulse calibration 
(see also speed Threshold table) 

Based on 4 pulses per meter distance 

Max. switched power output current 

1.2A 

Operating voltage range 

9Vdc to 32Vdc 

Input current 

Typ. <0.03A (Switch Power Output off) 
Max. <1.8A (Switch Power Output on state) 

Polarity 

Negative ground 

Operating temperature range 

-40°C to +85°C 

Dimensions (without connector) 

44mm x 64mm x 16mm 

Weight (including connector tail) 

approx. 35g 

Vehicle mounting 

Housing with opening lugs for fixing e.g. with a cable tie 

Plug with cable tail, cable length 

300mm +/- 20mm 

Approvals:

 CE, ECE Regulation No. 10 Revision 4 

(“E-marking”), FCC 

 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation. 
Any change or modifications not expressly approved by the responsible party responsible for 
compliance could void the user’s authority to operate the equipment. 

Specifications subject to change. Sous réserve de modifications techniques. Änderungen der technischen Daten vorbehalten. 
Specifiche soggette a variazioni. Las especificaciones están sujetas a cambios. Wijzigingen in specificaties voorbehouden. As 
especificações estão sujeitas a alterações. Спецификация может изменяться. 