•  All openings in the wall behind the

appliance or in the floor under the

appliance should be sealed.

•  Keep appliance area clear and free from

combustible materials, gasoline and other

flammable vapors.

•  Disconnect the electrical supply prior to

servicing or cleaning.

•  When removing the appliance for cleaning

or service, disconnect AC power supply

and carefully remove the appliance by

pulling forward.

•  Electrical requirements are listed in the

product specifications under the electrical

requirements section.

Recommendations for Unpacking

•  Products are shipped on pallets with foam

footings and corrugated inner-packing

and exterior hoods.

•  Products are anchored to the pallet using

metal straps that are screwed to the

bottom of the product and the pallet.

• 

DO NOT

remove protective packaging

until you are ready to perform the

installation.

•  To remove the packaging, first remove the

staples located at the bottom perimeter

of the corrugated cover.

•  Remove the corrugated cover by lifting 

it off the product and remove the inner-

packing.

•  Detach the product from the metal anchor

strip by removing the attachment screw.

• 

DO NOT 

remove the protective wrapping

from the product control panel until the

product is installed.

Recommendations for Moving

•  Only proper equipment should be used to

move products.

• 

ALWAYS

take steps to protect flooring at

the installation location when moving

products.

11

WARNING

DO NOT

use the handle or oven door 

to lift the oven. Remove door before
installation to ensure that it is not used to
lift the unit. 

DO NOT 

lift or carry the door

by the handle.

CAUTION

The oven is heavy—use extreme care
when handling.

Electrical Requirements

• Oven requires a separate, grounded 

4-wire, 240V (AC), 30 amp (single ovens)

and 50 amp (double ovens) service with

its own circuit breaker.

• Wire sizes and connections must conform

with the rating of the appliance and to the

requirements of the National Electrical

Code, ANSI/NFPA-70 – latest edition, or

Canadian Electrical Code, CSA 

C22.1-1982 and C22.2 No. 01982 –

latest edition, and all local codes and

ordinances.

• Oven must be connected to the proper

electrical voltage and frequency as

specified on the model/serial rating plate

(located inside the vent ont the right sode

of the oven).

• Oven must be connected to grounded

metal permanent wiring system. Check

with a qualified electrician to make sure

the oven is properly grounded.

DO NOT

ground to a gas pipe.

DO NOT

use an extension cord with this

appliance, because this may result in

electrical shock or other personal injury.

• This unit is equipped with a No. 10

ground wire in the conduit.

• The electrical conduit must be kept to the

top left for a flush installation. 

NEVER

cut

the conduit.

• Connect the flexible armored cable

directly to 4-wire, 240V household service.

If codes permit and separate grounding

wiring is used, we recommend that a

qualified electrician determine the

grounding path and that the wire gauge is

in accordance with local codes.

• Junction boxes installed on rear wall

directly behind oven must be recessed .

• A UL-Listed conduit connector must be

provided at the junction box.

DO NOT

install a fuse in the neutral or

grounding circuit. We recommend a time-

delayed fuse or circuit breaker. Connect

directly to the fused disconnect (or circuit

breaker box) through flexible armored, or

non-metallic sheathed, copper cable (with

grounding wire).

10

Содержание CRDDOE306

Страница 1: ...Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit us online at www brigade ca F21150 EN 030113 BRIGADE Built In Elect...

Страница 2: ...es which WILL result in severe personal injury or death DANGER Hazards or unsafe practices which COULD result in severe personal injury or death Hazards or unsafe practices which COULD result in minor...

Страница 3: ...E SUCH USE MAY RESULT IN FIRE ELECTRICAL SHOCK OR OTHER PERSONAL INJURY WARNING This appliance should not be used for space heating This information is based on safety considerations WARNING The use o...

Страница 4: ...rd 3 8 cu ft Oven volume total oven cavity 4 3 cu ft Note To install the oven in a flush mount application the flush mount accessory kit D30FTS for single ovens and D30FTD for double ovens is required...

Страница 5: ...5 2 cm B 25 1 4 64 1 cm C 51 1 2 130 8 cm Finished Surfaces Vertical Blocking E D F LEGEND Blocking Finished Surfaces Screw Screw Vertical Blocking Distance will vary depending on the cabinet A B Top...

Страница 6: ...andle CAUTION The oven is heavy use extreme care when handling Electrical Requirements Oven requires a separate grounded 4 wire 240V AC 30 amp single ovens and 50 amp double ovens service with its own...

Страница 7: ...circuit Double oven units require a 50 amp circuit Note A minimum of 2 spacing above and below the oven to any adjacent items is required for ventilation purposes It is recommended that 3 4 or thicker...

Страница 8: ...DO NOT use a metal knife spatula or any other metal tool to scrape stainless steel surfaces Scratches are almost impossible to remove 2 The interior of the oven should be washed thoroughly with hot s...

Страница 9: ...Low Broil function inner broil element only h Check Self Clean function Door will lock in approximately 30 seconds the center and outside broil elements will turn ON and the bake element will turn ON...

Страница 10: ...__________ ________________________________________________________________________________________________________________________________________________________ ____________________________________...

Отзывы: