Note:
It is recommended to leave
Hard AL_PA
unchecked unless you are
conversant with the lower levels of the Fibre Channel protocol, as certain
AL_PA addresses are reserved.
The
Enable tERP
check box, which is only present for 8Gb/s cards, will enable or disable the Target
Error Recovery Protocol for the port. tERP will attempt to recover frames that are missed or time
out during transfer. For tERP to correctly function, the connected initiator must also support tERP.
Clicking
Save
will save the configuration to memory for use at the next reboot.
Connected Hosts
To list which hosts are connected to the Gateway, select a port under
Fibre Channel Interfaces
,
then select the icon labelled
View all the Fibre Channel initiators which have logged into this target
port
. The following will then be displayed:
Port Map
The
Port Map
page allows the administrator to assign devices to Fibre Channel ports with a fixed
Logic Unit Number (LUN).
Once the Fibre Channel interface has been configured, the target devices can be assigned to the
Fibre Channel ports.
From the
Fibre Channel Target Management Console
page select the
Port Map
icon.