BridgeWave AR60X Скачать руководство пользователя страница 40

AR60X Installation Manual

 

580­00517, rev B 

34

 

License Restrictions

. BridgeWave reserves all other rights to the Software not specifically licensed hereunder. Buyer has no right to, and agrees not 

to sell, transfer, rent, copy, reverse engineer, reverse compile, decrypt, or reduce to human readable form to gain access to trade secrets or confidential 
information, modify or create derivative works of, or grant to any third party any rights in the Software, or permit any third party to do any of these 
prohibited acts, without BridgeWave’s prior written consent. Buyer agrees to protect the Software licensed hereunder in a manner consistent with the 
maintenance of BridgeWave’s ownership and proprietary rights therein, including displaying of any copyright and trademark notices in all Software 
as incorporated by BridgeWave.

 

Term and Termination.

 This License is effective until terminated. Buyer may terminate this License at any time, provided that Buyer’s termination 

does  not  entitle  Buyer  to  any  refund  of  purchase  or  license  fees.  BridgeWave  may  terminate  Buyer’s  rights  under  this  License immediately  upon 
written  notice  if  Buyer  fails  to  comply  with  any  provision  of  this  License.  Upon  termination,  Buyer  must  destroy  all  copies  of  Software  in  its 
possession or control.

 

Export.

  Software and Products, including technical data, may be subject to U.S. export control laws, including the U.S. Export Administration Act 

and  its  associated  regulations,  and  may  be  subject  to  export  or  import  regulations  in  other  countries.  Buyer  agrees  to  comply strictly  with  all  such 
regulations and acknowledges that Buyer has the responsibility to obtain licenses to export, re­export, or import Software and Products.

 

Restricted Rights.

 BridgeWave’s commercial software and commercial computer software documentation is provided to United States Government 

agencies  in  accordance  with  the  terms  of  this  Limited  Hardware  Warranty  and  Software  License,  and  per  subparagraph  “©”  of  the  “Commercial 
Computer  Software – Restricted Rights” clause at FAR 52.227­19 (June 1987). For DOD agencies, the restrictions  set  forth in  the “technical Data­ 
Commercial Items” clause at DFARS 252.227­7015 (Nov 1995) shall also apply. 

LIMITATION OF REMEDY AND LIABILITY PROVISIONS

 

EXCLUSIVE REMEDIES

. THE REMEDIES SET FORTH IN THIS LIMITED WARRANTY  AND SOFTWARE LICENSE ESTABLISH THE 

ENTIRE  OBLIGATION  OF  BRIDGEWAVE  AND  BUYER’S  SOLE  REMEDY  IN  REGARD  TO  CLAIMS  RELATING  TO  BREACH  OF 
WARRANTY  OR  INTELLECTUAL  PROPERTY  RIGHTS  INCLUDING  BUT  NOT  LIMITED  TO  CLAIMS  DIRECTED  TO  THE 
INFRINGEMENT OR MISAPPROPRIATION OF PATENTS, COPYRIGHTS, TRADE SECRETS  AND OTHER PROPRIETARY RIGHTS FOR 
THE PRODUCTS.

 

NO  CONSEQUENTIAL  DAMAGES

.  IN  NO  EVENT  SHALL  EITHER  PARTY,  OR  EITHER  PARTY’S  SUPPLIERS,  OFFICERS, 

DIRECTORS,  EMPLOYEES,  AGENTS,  SHAREHOLDERS  OR  CONTRACTORS  (“RELATED  PARTIES”),  BE  LIABLE  TO  THE  OTHER 
PARTY  OR  ITS  RELATED  PARTIES  FOR  CONSEQUENTIAL,  INDIRECT,  INCIDENTAL,  SPECIAL,  PUNITIVE  OR  EXEMPLARY 
DAMAGES  OR  FOR  COST  OF  COVER,  LOST  REVENUES,  LOST  PROFITS  OR  LOST  DATA  OR  OTHER  ECONOMIC  LOSS  ARISING 
FROM  ANY  CAUSE  INCLUDING  BUT  NOT  LIMITED  TO  BREACH  OF  WARRANTY,  BREACH  OF  CONTRACT,  TORT,  STRICT 
LIABILITY,  OR  FAILURE  OF  ESSENTIAL  PURPOSE  EVEN  IF  BRIDGEWAVE  HAS  BEEN  ADVISED  OF  THE  POSSIBILITY  OF  SUCH 
DAMAGES. THE FOREGOING LIMITATIONS SHALL  APPLY  EVEN IF THE  ABOVE­STATED WARRANTY FAILS OF ITS ESSENTIAL 
PURPOSE. BECAUSE SOME STATES OR JURISDICTIONS DO NOT ALLOW LIMITATIONS OR EXCLUSIONS OF CONSEQUENTIAL OR 
INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO BUYER.

 

LIMIT  ON  LIABILITY

.  THE  MAXIMUM  LIABILITY  OF  BRIDGEWAVE,  AND  ITS  RELATED  PARTIES,  TAKEN  AS  A  WHOLE,  FOR 

ANY AND ALL CLAIMS IN CONNECTION WITH THE PRODUCTS AND SOFTWARE, INCLUDING BUT NOT LIMITED TO CLAIMS FOR 
BREACH OF WARRANTY, BREACH OF CONTRACT, TORT, STRICT LIABILITY, FAILURE OF ESSENTIAL PURPOSE OR OTHERWISE, 
SHALL  IN  NO  CIRCUMSTANCE  EXCEED  THE  PURCHASE  PRICE  PAID  BY  BUYER  TO  BRIDGEWAVE  OR  BRIDGEWAVE’S 
AUTHORIZED CHANNEL PARTNERS FOR THE PRODUCTS AND SOFTWARE.

 

Statute  of  Limitations

.  Any  action  for  breach  of  or  to  enforce  any  right  under  this  Limited  Hardware  Warranty  or  Software  License  shall  be 

commenced within one (1) year after the cause of action accrues, or reasonably could have been discovered, or it shall be deemed waived and barred.

 

Administrative Provisions.

 This Limited Hardware Warranty and Software License shall be governed by and construed in accordance with the laws 

of the State of California, without reference to principles of conflict of laws, provided that for customers located in a member state of the European 
Union, Norway  or  Switzerland, English law  shall apply. The  United Nations Convention  on the International Sale  of Goods  shall  not apply. If any 
portion hereof is found to be void or unenforceable, the remaining provisions of the Limited Hardware Warranty and Software License shall remain in 
full  force  and  effect.  Except  as  expressly  provided  herein,  the  Limited  Hardware  Warranty  and  Software  License  constitutes  the  entire  agreement 
between  the  parties  with  respect  to  warranties  on  the  Hardware  and  Licensing  of  the  Software,  and  supersedes  any  conflicting or  additional  terms 
contained in any prior or contemporaneous discussion, negotiation or agreement, including those in any purchase order or order acknowledgment.

Содержание AR60X

Страница 1: ...Making connections in a high speed world AR60X Wireless Ethernet Links Installation Manual P N 580 00517 Revision B January 2008...

Страница 2: ...e commitments to the purchaser set forth in its Standard Terms and Conditions of Sale for a delivered product This publication has been prepared for professional and properly trained personnel and the...

Страница 3: ...oor equipment must be properly grounded to provide some protection against voltage surges and built up static charges In the event of a short circuit grounding reduces the risk of electrical shock For...

Страница 4: ...device may not cause harmful interference and 2 This device must accept any interference that may cause undesired operation Equipment Precautions Water and Moisture All AR 60X links are designed to w...

Страница 5: ...a Location 3 2 6 Cabling 4 2 7 Grounding Lightning 5 2 8 Environmental 6 2 9 Cabling Diagram 7 3 Installation 8 3 1 General 8 3 2 Equipment Unpacking 8 3 3 Equipment Inventory 9 3 4 Installation Tools...

Страница 6: ...NOTE statements have been placed in various sections throughout this document to alert personnel of possible traffic affecting issues and to provide additional tips and helpful information These stat...

Страница 7: ...Customer Service for assistance Santa Clara CA USA Tel 408 567 6906 Fax 408 567 0775 Email support bridgewave com Return Material Authorization RMA Should BridgeWave equipment have to be returned for...

Страница 8: ...r operation Fortunately the links are relatively short and obstructions in the path can easily be identified Binoculars can ease viewing in poor light conditions The planning should include an investi...

Страница 9: ...roduct and region BridgeWave s Path Availability Calculator can be used To obtain the latest version of BridgeWave s Path Availability Calculator contact BridgeWave s Customer Service or search the eS...

Страница 10: ...pe Up to 270 meters 62 5 125 m Up to 500 meters 50 125 m Table 2 5 Fiber Cable Types Each radio includes a 100 240 VAC power adaptor suitable for indoor operation that converts the AC voltage from the...

Страница 11: ...per techniques in lightning prone geographic areas may pose a danger to local personnel The source and connection points for the building to earth ground in the vicinity of the antenna location should...

Страница 12: ...A surge suppressor must be placed within the radio enclosure to protect the radio electronics and at the building exit entrance to protect the indoor equipment For more information on recommended acc...

Страница 13: ...AR60X Installation Manual 7 580 00517 rev B 2 9 Cabling Diagram Following is a diagram detailing the equipment and cabling found on a typical installation of BridgeWave s 60GHz radio equipment...

Страница 14: ...s Subsections 3 9 and 3 10 contains information necessary for aligning the antennas 3 2 Equipment Unpacking The radio system equipment will arrive in two boxes one box for the low band radio and one b...

Страница 15: ...s 2 ea DC power connection set Includes 2 prong DC plug and 2 ea slip fit plugs receptacles 2 ea Antennas radios are attached to back of antenna in vertical polarization 1 ea Hard reset box AR60X Ante...

Страница 16: ...Screwdriver slotted 0 1 inch 2 5mm wide Open end wrench 11 32 9mm Open end wrench 9 16 14mm 2 ea Open end wrench 1 2 13mm Ratchet with 6 inch 15cm extension and 9 16 inch 14mm deep socket Wire stripp...

Страница 17: ...ion 2 BridgeWave Communications Inc disclaims any responsibility or liability for damage or injury resulting from incorrect or unsafe installation practices 3 The antenna has been formed to a very clo...

Страница 18: ...nual 580 00517 rev B 12 2 Attach the lower pole mount as shown Figure 3 3 Figure 3 4 Hardware Flat washer bushing inside eye flat washer lock washer bolt Confirm that the Mount is centered as shown Ti...

Страница 19: ...ration Figure 3 6 When using the left side radio mount position the antenna drain plugs must be rotated to the top drain holes and the bottom holes must be open to allow for proper drainage Note the p...

Страница 20: ...n the back of the antenna in the vertical polarization position that is the diamond marking see figure 3 8 below on the front of the radio housing is to the right when viewed from the front of the rad...

Страница 21: ...de of the link set in the vertical polarization will not operate properly It is also critically important that a high band radio is paired with a low band radio to ensure the system will operate prope...

Страница 22: ...for details Figure 3 10 Attaching the radio to the back of the antenna 8 Adjust azimuth Side to Side 1 Loosen the 4 Azimuth lock bolts 2 Adjust eyebolt length using a 9 16 open end wrench to required...

Страница 23: ...he elevation and vice versa 8 Adjust elevation up down Figure 3 12 Elevation up down adjustment Begin the alignment process with the antenna in a level attitude When adjusting elevation it is better t...

Страница 24: ...an automatic calibration once the fiber is inserted into the radio and this calibration will not operate properly if the radio is not properly aligned If this inadvertently occurs while the radio is p...

Страница 25: ...io to the network termination equipment switch or router with 10 100Base T port The cable should be looped around the inside of the enclosure to provide strain relief Connect the Ethernet cable to the...

Страница 26: ...nected to the radio and to maintain proper bend radius of the fiber cable Ground Cabling The preferred method for grounding the radio unit is to ground the mast or wall mount bracket to a ground sourc...

Страница 27: ...f the signal which in turn results in standing waves Ice layers are not likely to exist for extended periods as ice tends to melt In cold climates when the radome is below freezing temperature ice doe...

Страница 28: ...e shield on one radio Two kits are required per link Qty Description 1 ea Ice Shield Canopy 1 ea Ice Shield Clamp 6 3 8 3 Installation Instructions 1 Remove the protective liner from the plastic canop...

Страница 29: ...80 00517 rev B 5 Align the canopy to the back edge of the radome and position the clamp 1 to 3 away from the edge 6 Tighten the clamp until snug Do Not Overtighten Remove canopy when its not snowing t...

Страница 30: ...ults in the highest RSL voltage reading See Section 3 9 to determine the proper use of the supplied test cable in order to read the RSL voltage Verify that the RSL voltage falls within the expected ra...

Страница 31: ...e back cover stops i e when it hits the metal ring on the back metal plate The installation is now complete Auto Calibration States State Description Unit powered up no fiber connected Unit will be in...

Страница 32: ...ss link Quality Voltages between 1 5V and 3 0V indicate a low rate of errors that the forward error correction will correct The lower the voltage the more errors are being corrected Quality Voltages b...

Страница 33: ...op view of test cable provided to check Link Quality Receive Signal level 2 To read the Link Quality value of the radio insert GND ground and QUAL banana plugs into the voltmeter Note the Link Quality...

Страница 34: ...oltage should be 3 3V although dips in voltage are acceptable during periods of precipitation 10 100Base T LEDs each side next to socket opening left should be green if connected link up and right fla...

Страница 35: ...ured to not enter error disable state due to link up down transitions since these may occur during periods of very heavy rain It is possible to disable auto negotiation on the radio s fiber interface...

Страница 36: ...ngth of the cable or use larger gauge cable See Section 2 6 Fiber light lit at radio but not on network equipment LSP is enabled and radio link is down This is normal behavior TX and RX fibers are swa...

Страница 37: ...Section 3 6 Link exceeds maximum specified range Verify that maximum path length has not been exceeded Low link quality voltage Antennas are not aligned for maximum RSL Verify antenna alignment using...

Страница 38: ...B 32 Appendix B RSL Voltage vs Distance AR60X RSL Voltage vs Distance 0 5 1 5 2 5 500 1000 1500 2000 2500 Distance m R S L V o l t a g e V ABOVE CALIBRATED RANGE Align Ante nnas to M ax voltage and c...

Страница 39: ...ment of the replacement Product to Buyer and shall expire on the later of ninety 90 days after shipment date or the last day of the original Warranty Period with respect to the replaced Product All re...

Страница 40: ...EMENT OR MISAPPROPRIATION OF PATENTS COPYRIGHTS TRADE SECRETS AND OTHER PROPRIETARY RIGHTS FOR THE PRODUCTS NO CONSEQUENTIAL DAMAGES IN NO EVENT SHALL EITHER PARTY OR EITHER PARTY S SUPPLIERS OFFICERS...

Отзывы: