BrickElectric BEM11000 Скачать руководство пользователя страница 31

www.BrickElectric.com 

035  - 

reserved parameter 

default value: - 

range: - 

036  - 

reserved parameter 

default value: - 

range: - 

037  - 

reserved parameter 

default value: - 

range: - 

038  - 

reserved parameter 

default value: - 

range: - 

039  - 

reserved parameter 

default value: - 

range: - 

040  - 

reserved parameter 

default value: - 

range: - 

041  - 

reserved parameter 

default value: - 

range: - 

042  - 

reserved parameter 

default value: - 

range: - 

043  - 

reserved parameter 

default value: - 

range: - 

044  - 

reserved parameter 

default value: - 

range: - 

045  IOVAL01 

I/O value channel 1, 0 = off, 1 = on 

default value: - 

range: - 

046  IOVAL02 

I/O value channel 2, 0 = off, 1 = on 

default value: - 

range: - 

047  IOVAL03 

I/O value channel 3, 0 = off, 1 = on 

default value: - 

range: - 

048  IOVAL04 

I/O value channel 4, 0 = off, 1 = on 

default value: - 

range: - 

049  IOVAL05 

I/O value channel 5, 0 = off, 1 = on 

default value: - 

Содержание BEM11000

Страница 1: ...M11000 is POE Supply Input Ethernet Remote I O Module with 2 output Relays channels remote control module Its Ethernet connector provides 10 100baseT interface It supports EasyBus simple solution HTTP...

Страница 2: ...cations 7 4 2 Save Parameters 7 4 3 Reboot 7 4 3 DHCP Function 8 4 4 Static IP Address 8 4 5 Relay outputs control 9 4 7 Http port setting 11 4 8 Hardware reset button 12 4 9 Identification customized...

Страница 3: ...to 85 Module Size 91mm x 53mm x 18mm Weight 1 2 Connection Diagram Fig 1 1 2 Specifications 2 1 Recommended Operating Conditions Parameters At T 25 unless otherwise specified Symbol Values Unit Min Ty...

Страница 4: ...ault Settings IP Setting IP address 192 168 1 105 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 DHCP disable Latest Firmware Version V100 0 02 You can download latest firmware for free HTTP function S...

Страница 5: ...e is to make it work by minimum steps For more information please refer to later chapters 3 1 HTTP Mode 1 Connect BEM11000 with your routers or computer via a standard Ethernet POE cable see fig 1 1 a...

Страница 6: ...tool if you don t have any or you don t know what a TCP test tool is you can use BE Manager it is within our software package Open it and see the following Fig 1 2 Fig 1 2 3 Click Connect button and w...

Страница 7: ...the module at the simple start manual delivered together with module package You can also change the MAC address to use your own MAC address 4 2 Save Parameters After power cycle BEM11000 will lose i...

Страница 8: ...t IP Address is 192 168 1 105 for all the following commands Enable Disable DHCP Note modification only effective after parameter saving and module reboot To Enable DHCP Web access URL http 192 168 1...

Страница 9: ...168 1 105 setpara 4 100 Socket command text setpara 1 192 setpara 2 168 setpara 3 2 setpara 4 100 Set static Gateway Address Note modification only effective after parameter saving and module reboot T...

Страница 10: ...ara 46 Normal ON OFF TOGGLE Normal on off toggle operation changes the relay output status immediately after receiving commands No timing features included Switches To switch off ch1 output Web access...

Страница 11: ...45 1 Socket command text getpara 45 1 4 7 Http port setting In default conditions HTTP port is always 80 if you enter directly in web browser a URL without any additional parameters But in some applic...

Страница 12: ...green and red LEDs are both on then continue to press the button for 10 seconds Module will erase its firmware and try to download latest firmware from Internet Please connect to internet when you do...

Страница 13: ...s both TCP Server and TCP Client mode both mode has its application advantage Additionally one configurable communication watchdog can be setup to monitor the connection between Ethernet relay module...

Страница 14: ...for example to 5000 Web access URL http 192 168 1 105 setpara 131 5000 Socket command text setpara 131 5000 EasyBus Client Mode For applications it is better to listen at the server and let the relay...

Страница 15: ...ss URL http 192 168 1 105 setpara 130 5000 Socket command text setpara 130 5000 EasyBus Client DNS Enable For some applications the remote server IP address is assigned by DHCP so to get the actual ad...

Страница 16: ...rtain moment the TCP connection will be lost You can actively access http interface to reboot the relay module so it will try to connect to server again but you can also use the additional watchdog pr...

Страница 17: ...to ping mode select default is fixed IP mode 2 Configure Fixed IP or Domain Name default is your gateway IP 3 Configure programmable reboot sequence default is no action 4 Set time between pings defau...

Страница 18: ...nnel 1 Web access URL Write http 192 168 1 105 setpara 101 192 setpara 102 168 setpara 103 1 setpara 104 100 Read http 192 168 1 105 getpara 101 192 getpara 102 168 getpara 103 1 getpara 104 100 Socke...

Страница 19: ...ase of remote IP device becomes unresponsive auto ping function will run a pre set reboot sequence to make a customized reboot action according to your application For this function the following comm...

Страница 20: ...65535 seconds Normally 60 seconds should be useful for most applications To setup time you need to set 2 parameters time unit and time Auto Ping Channel 1 1 To set time unit to millisecond setpara 45...

Страница 21: ...xt Write setpara 158 5 Read getpara 158 1 6 Delay time after reboot After auto ping detected an external controller unresponsive failure and running a reboot sequence it is naturally necessary that th...

Страница 22: ...ping function please make sure your every other setting is finished so it can work correctly If you save settings after auto ping start when power on the device auto ping will automatically start aga...

Страница 23: ...multiple output module When one input is mapped to one or more outputs then if this input is triggered all the outputs that it mapped will also be triggered immediately 6 1 X Connect Map Setting Each...

Страница 24: ...3 VWSL3 X Connect CH3 input select 1 8 105 4 VWSL4 X Connect CH4 input select 1 8 106 5 VWSL5 X Connect CH5 input select 1 8 107 6 VWSL6 X Connect CH6 input select 1 8 108 7 VWSL7 X Connect CH7 input...

Страница 25: ...CH7 target IP 4 0 255 161 8 VWSIP81 X Connect CH8 target IP 1 0 255 162 8 VWSIP82 X Connect CH8 target IP 2 0 255 163 8 VWSIP83 X Connect CH8 target IP 3 0 255 164 8 VWSIP84 X Connect CH8 target IP 4...

Страница 26: ...5 Relay 2 output control Write Read To look into Modbus TCP frame structure or create your own Modbus TCP program here are the detailed message frame for each command To switch on relay channel 1 outp...

Страница 27: ...lic 192 168 1 105 1 3 6 SNMP get command read a SNMP entry for example to read relay channel 1 snmpget v 1 c public 192 168 1 105 1 3 6 1 4 1 55333 1 1 45 SNMP get command read a SNMP entry for exampl...

Страница 28: ...earning the old fashioned and very detailed industry automation communication protocol before they can really start to do anything How to send a correct switch command Example set parameter 45 to valu...

Страница 29: ...mask 4 default value 0 range 0 255 013 MAC1 MAC address 1 default value XX unique by every device range 0 255 014 MAC2 MAC address 2 default value XX unique by every device range 0 255 015 MAC3 MAC a...

Страница 30: ...max 48 chars 026 TIMEOP total operation time in seconds default value range 027 TSYSON operation time in seconds after power on reset to 0 after each reboot default value range 028 SAVE save parameter...

Страница 31: ...041 reserved parameter default value range 042 reserved parameter default value range 043 reserved parameter default value range 044 reserved parameter default value range 045 IOVAL01 I O value channe...

Страница 32: ...value channel 10 0 off 1 on default value range 055 IOVAL11 I O value channel 11 0 off 1 on default value range 056 IOVAL12 I O value channel 12 0 off 1 on default value range 057 IOVAL13 I O value c...

Страница 33: ...brickelectric com Skype Online Support 86 182 1730 3961 WhatsApp Online Support 86 182 1730 3961 Call Us 86 182 1730 3961 If you have any questions or any customized software hardware requirement plea...

Отзывы: