BrickElectric BEM107 Скачать руководство пользователя страница 10

www.BrickElectric.com 

To reboot device: 

Web access URL:   

http://192.168.1.105/reboot=1 

Socket command text: 

reboot=1; 

 

4.3 DHCP Function 

BEM107 supports both DHCP and static IP Addressing. For communication reliability, we 

recommend  using  a  Static  IP  Address  when  you  feel  comfortable  doing  so.  This  will 

ensure that the device will always be where you expect it to be, when you try to connect to 

it. 

 

DHCP  stands  for  Dynamic  Host  Configuration  Protocol  and  basically  means  that  your 

router will assign the first available IP Address in the list of IP Addresses Range to your 

device. This technology makes network devices very easy to use, but it is not as reliable 

because in certain circumstances it will cause the IP Address it assigns to change. DHCP 

mode is recommended when you only use Internet control, or your local software is able 

to detect module IP changes. 

 

Assuming module current IP Address is 192.168.1.105 for all the following commands. 

 

Enable/Disable DHCP 

Note: modification only effective after parameter saving and module reboot. 

To Enable DHCP: 

Web access URL:   

http://192.168.1.105/dhcp=1 

Socket command text: 

dhcp=1; 

 

To Disable DHCP: 

Web access URL:   

http://192.168.1.105/dhcp=0 

Socket command text: 

dhcp=0; 

 

4.4 Static IP Address 

This technology is the antithesis of DHCP in that it is manually set IP address and does 

not dynamically change without direct action. The disadvantage of this method is that, if 

done  incorrectly,  can  make  the  module  unreachable  through  any  standard  means.  This 

usually happens when an IP Address is statically set to an IP Address outside of the range 

of the router, or another device on the network obtains this IP address via DHCP. If this 

happens, see the 

section of this guide titled “Reset Function”. This method is the preferred 

and more reliable way to  handle network IP Address allocation. For improved reliability, 

the IP Address assigned to this Module should be reserved on your router. 

Содержание BEM107

Страница 1: ...nnel and provide with both enclosed and open type housing Its Ethernet connector provides 10 100baseT interface It supports EasyBus TCP HTTP control and Internet control protocols suitable for being u...

Страница 2: ...onality 9 4 1 Basic Network Communications 9 4 2 Save Parameters 9 4 3 Reboot 9 4 3 DHCP Function 10 4 4 Static IP Address 10 4 5 Relay outputs control 11 4 6 Password protection 16 4 7 Http port sett...

Страница 3: ...ion Temperature 30 to 85 Module Size 75mmx50mmx20mm Weight 1 2 Connection Diagram Fig 1 1 2 Specifications 2 1 Recommended Operating Conditions Parameters At T 25 Vsuplly 5V unless otherwise specified...

Страница 4: ...ress 192 168 1 105 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 DHCP disable Latest Firmware Version V107 0 00 You can download latest firmware for free HTTP function State Enable Port 80 Internet Co...

Страница 5: ...rk by minimum steps For more information please refer to later chapters 3 1 HTTP Mode 1 Connect BEM107 with your routers or computer via a standard Ethernet cable And then power it on with 5 24VDC pow...

Страница 6: ...2 2 Open any TCP test tool if you don t have any or you don t know what a TCP test tool is you can use BE Manager it is within our software package Open it and see the following Fig 1 2 Fig 1 2 3 Cli...

Страница 7: ...www BrickElectric com Fig 1 3...

Страница 8: ...ee fig 1 1 at page 2 2 Open Hello Brick app for android at any android phone register a user and then have fun with Internet control 3 If you need online help or need to contact us for customized func...

Страница 9: ...ual delivered together with module package 4 2 Save Parameters After power cycle BEM107 will lose its parameter modifications if you don t actively require it to save modified parameters into internal...

Страница 10: ...Assuming module current IP Address is 192 168 1 105 for all the following commands Enable Disable DHCP Note modification only effective after parameter saving and module reboot To Enable DHCP Web acce...

Страница 11: ...on only effective after parameter saving and module reboot To set static Gateway Address to 192 168 2 1 Web access URL http 192 168 1 105 gateway 192 168 2 1 Socket command text gateway 192 168 2 1 Se...

Страница 12: ...ands No timing features included Switches To switch off ch1 output Web access URL http 192 168 1 105 k01 0 Socket command text k01 0 To switch on ch1 output Web access URL http 192 168 1 105 k01 1 Soc...

Страница 13: ...ommands and wait for a predefined time period then automatically switches to opposite status Switches To pulse on ch1 output you can input by require web access Web access URL http 192 168 1 105 k01 3...

Страница 14: ...imer K0xT1 timer supports from 1ms to 4294967295 second K0xT1 needs to be set for time value and K0xU1 needs to be set for timer value unit Default value for K0xT1 is 1000 and default unit for K0xU1 i...

Страница 15: ...6 Timing Features To set up customized timer for relay cycle outputs timer T1 and T2 are used and need to be set Each relay channel has two independent timers K0xT1 and K0xT2 time period supports from...

Страница 16: ...Mode Read current relay output status for feedback control Module will return the current status in web content or socket text depending on how do you send the command To read relay ch1 current status...

Страница 17: ...eeded for port forwarding or any other reasons For example you can force your web browser to access http content at port 8080 to do so you need to enter http url 8080 This module is able to customize...

Страница 18: ...cation customized information When more than one modules are installed in the field it is necessary to be able to read the identification information from module for example serial number Except for s...

Страница 19: ...vice firmware version you can read device firmware version by communication for the purpose of better identification the device or diagnosis To read device firmware version Web access URL http 192 168...

Страница 20: ...output module When one input is mapped to one or more outputs then if this input is triggered all the outputs that it mapped will also be triggered immediately 5 1 X Connect Map Setting Each BEM Seri...

Страница 21: ...ct 1 8 105 4 VWSL4 X Connect CH4 input select 1 8 106 5 VWSL5 X Connect CH5 input select 1 8 107 6 VWSL6 X Connect CH6 input select 1 8 108 7 VWSL7 X Connect CH7 input select 1 8 109 8 VWSL8 X Connect...

Страница 22: ...61 8 VWSIP81 X Connect CH8 target IP 1 0 255 162 8 VWSIP82 X Connect CH8 target IP 2 0 255 163 8 VWSIP83 X Connect CH8 target IP 3 0 255 164 8 VWSIP84 X Connect CH8 target IP 4 0 255 165 9 VWSIP91 X C...

Страница 23: ...5 Relay 1 output control Write Read 00000 1 02 Input 1 status read Read To look into Modbus TCP frame structure or create your own Modbus TCP program here are the detailed message frame for each comma...

Страница 24: ...e old fashioned and very detailed industry automation communication protocol before they can really start to do anything How to send a correct switch command Example switch on relay channel 1 K01 1 Ex...

Страница 25: ...192 range 0 255 011 SIP2 module IP address 2 default value 168 range 0 255 012 SIP3 module IP address 3 default value 1 range 0 255 013 SIP4 module IP address 4 default value 105 range 0 255 014 Reser...

Страница 26: ...ved parameter default value range 027 Reserved parameter default value range 028 Reserved parameter default value range 029 K1U1 Relay K1 timer T1 unit selector 0 ms 1 second default value 0 range 0 1...

Страница 27: ...rved parameter default value range 040 Reserved parameter default value range 041 Reserved parameter default value range 042 Reserved parameter default value range 043 Reserved parameter default value...

Страница 28: ...range 054 Reserved parameter default value range 055 Reserved parameter default value range 056 Reserved parameter default value range 057 Reserved parameter default value range 058 Reserved paramete...

Страница 29: ...K2T2 Relay K2 timer T2 value default value 1000 range 0 65535 069 Reserved parameter default value range 070 Reserved parameter default value range 071 Reserved parameter default value range 072 Rese...

Страница 30: ...rved parameter default value range 084 Reserved parameter default value range 085 Reserved parameter default value range 086 Reserved parameter default value range 087 Reserved parameter default value...

Страница 31: ...P Device model type default value 107 range 100 DEVSN Device serial number default value range 101 PIP1 1 Ping monitor 1 IP address 1 default value 192 range 0 255 102 PIP1 2 Ping monitor 1 IP address...

Страница 32: ...d parameter default value range 113 Reserved parameter default value range 114 Reserved parameter default value range 116 Reserved parameter default value range 117 Reserved parameter default value ra...

Страница 33: ...rameter default value range 130 Reserved parameter default value range 131 Reserved parameter default value range 132 Reserved parameter default value range 133 PNAME1 Ping monitor 1 domain name max 5...

Страница 34: ...AIT 5 K02 0 range 143 Reserved parameter default value range 144 Reserved parameter default value range 145 Reserved parameter default value range 146 Reserved parameter default value range 147 Reserv...

Страница 35: ...r 2 max allowed no response failure times before reboot default value 3 range 0 65535 159 Reserved parameter default value range 160 Reserved parameter default value range 161 Reserved parameter defau...

Страница 36: ...lector after reboot 0 ms 1 second default value 0 range 0 1 174 PDU2 Ping monitor 2 delay timer unit selector after reboot 0 ms 1 second default value 0 range 0 1 175 Reserved parameter default value...

Страница 37: ...ult value 0 range 0 1 183 Reserved parameter default value range 184 Reserved parameter default value range 185 Reserved parameter default value range 186 Reserved parameter default value range 187 Re...

Страница 38: ...t us Email brickelectric hotmail com WhatsApp Online Support 86 182 1730 3961 Call Us 86 182 1730 3961 If you have any questions or any customized software hardware requirement please send an email to...

Отзывы: