background image

FEET

Thread each foot into the bottom of the legs on the Conical leaving about half an inch of thread visible. Adjust feet as 
needed to level conical if the surface is uneven.

LID GASKET

  Flip the lid upside down and install a section of 

the gasket, flat side seating into the lid groove 
first. Lightly push the gasket in,  installing it in the 
groove as you go around the lid.

  Please note, the gasket is larger than the groove 

to help ensure a tight seal during fermentation. 
Continue pushing the gasket against itself and into 
the lid until it is in the groove and equally distributed 
without stretch points. Once you get the first piece 
of the gasket in the groove then you can use both 
hands to work the gasket around the lid and into 
the groove with your thumbs. (See video online)

LID CLAMP

  When installing the lid clamp, be careful to install 

it according to the pictures shown here. Improper 
installation can be hazardous to both equipment & 
user.  

  Ensure that the lid is centered on top of the conical 

body during installation. The two should be 
centered so that the clamp seals down evenly.

  Lid Clamp should be hand tightened fully.

BLOW OFF

 

Place 1.5" TC gasket into the open blow off port on the 
conical lid and fasten the Blowoff U Barb with a 1.5" TC 
clamp, ensuring that the U Barb is pointing downward 
off the side of the conical. Slide ½" Silicone tubing over 
the barbed side of the U Barb. It’s easiest to start with 
one side and then work it around until barbs are fully 
covered. The silicone should be fairly pliable to stretch over the barbs, but running it under hot water first will help make 
it even more pliable and easier to install.

THERMOWELL

Place 1.5" TC Gasket and Thermowell into the open port in front of the conical just below the etched BrewBuilt Logo 
and fasten in place using 1.5" TC clamp.

SAMPLE VALVE

Place 1.5" TC Gasket and Sample Valve into the open port halfway down the conical base on the front of the unit and 
fasten in place using 1.5" TC clamp. Make sure the Sample Valve is closed by turning it clockwise until it stops.

BUTTERFLY VALVE

The Butterfly Valve opens in one direction, so be sure to install it so the valve handle opens downward away from the 
conical bottom. Place 2" TC Gasket and Butterfly Valve on the bottom port of the conical and fasten in place using 2" 
TC clamp.

ASSEMBLING YOUR X1 

&

 X1 + CONICAL

GASKET 

ORIENTATION

FLAT SIDE INTO LID GROVE

GASKET 

INSTALLATION

WITH LID UPSIDE DOWN, PUSH FLAT END 

OF GASKET INTO LID GROOVE

IMPROPERLY INSTALLED CLAMP

MAKE SURE CLAMP IS PROPERLY ALIGNED AND 

 SECURELY CLOSED IN PLACE

PROPERLY INSTALLED IN CLOSED POSITION

BREWBUILT.COM

Содержание X1 UNI

Страница 1: ... UNI CONICAL ASSEMBLY INSTRUCTION GUIDE For X1 Uni X1 Uni CONTENTS PAGE 2 3 Cleaning Testing What s Included PAGE 4 Assembly PAGE5 How to Use The X1 Conical PAGE 6 8 HowtoUse TheX1 Conical PAGE 8 Warnings ...

Страница 2: ...ing your new conical fermenter GETTING STARTED CLEAN THE CONICAL Before your first use clean and rinse the conical along with all the parts fittings This will remove any leftover oil or dust from the manufacturing process We recommend using an alkaline cleaner like PBW WATER TEST After cleaning and rinsing we also recommend filling your conical with water and familiarizing yourself with its operat...

Страница 3: ...FLEX CHAMBER NEOPRENE JACKET PRESSURE PACK COOLSTIX Additional Parts Included With X1 Uni K F G E D J H I A B C L F G N O P M F G Q R S T U ...

Страница 4: ...lid and fasten the Blowoff U Barb with a 1 5 TC clamp ensuring that the U Barb is pointing downward off the side of the conical Slide Silicone tubing over the barbed side of the U Barb It s easiest to start with one side and then work it around until barbs are fully covered The silicone should be fairly pliable to stretch over the barbs but running it under hot water first will help make it even m...

Страница 5: ...nother added advantage is being able to harvest your yeast for use on future batches Regardless of whether you re dumping trub hops or yeast you will want to guide that slurry into a drain or receiving vessel like a bucket or jar Be sure to spray the Butterfly Valve down with sanitizer prior to dumping Also keep in mind that you will need to open one of the ports on the top of the conical to allow...

Страница 6: ...s oxygen that will be sent up through your beer If this happens post fermentation it could negatively impact the beer s flavor See below to learn how to use your Flex Chamber side ports to flush with CO2 COLLECTING AND DUMPING TRUB WITH FLEX CHAMBER The ability to remove trub and hop sediment is one of the key advantages of a conical fermenter With the butterfly valve open and the Flex Chamber att...

Страница 7: ...ure to help drop out solids we recommend using no more than 2 4 psi Prior to cold crashing you can apply around 5 psi head pressure to counteract the vacuum formed as the liquid contracts when the temperature drops significantly This would otherwise cause the tank to suck in oxygen via the blowoff You also have the option to force carbonate your beer while it s still in the tank Refer to a carbona...

Страница 8: ...s use a single rod CoolStix the 27 and 42 gallon models use the CoolStix Reactor Rod with four cooling rods The larger CoolStix Reactor Rod is made using a 4 TC fitting so you will need to remove the Pressure Pack top to insert the Reactor Rod After fermentation cooling is over you can replace the Reactor Rod with the Pressure Pack to sample and transfer under pressure Using Your CoolStix INLET OU...

Отзывы: