background image

15

AUTO-ON TIMER

Auto-on can only be set when the tower fan 

is on standby mode.
Press the   button on the remote. The   

symbol will begin to flash and “0.5” will 

display on the LED display screen. Press the 

 and   buttons on either the control panel or 

the remote until the desired number flashes 

on the LED display screen. 
Press the   button again on the remote to 

set the auto-on timer. The time will display 

on the LED screen and the   symbol 

will illuminate. The timer will start on the 

last selected mode, and the fan will start 

automatically once the time has elapsed.

n

 NOTE:

If TIMER is pressed on the remote but 

no action is taken, the tower fan will exit 

TIMER. Press the   button on the remote 

to return to TIMER.
The LED display screen will not display the 

remaining auto-off time, instead the display 

will return to the set fan setting. Press the 

 button on the remote and the remaining 

time will display on the display screen.
To cancel the auto-on time anytime once the 

timer is set, touch and hold the   button for 

2 seconds and the   symbol will no longer 

illuminate. 

n

 NOTE

• 

The auto-on timer can only be set when the 

fan is on standby mode.

• 

The tower fan will turn on once the auto-on 

timer has elapsed.

• 

The tower fan will operate on the last 

selected mode.

• 

To check the pre-set time left on the LED 

display screen, press the   button on 

the remote.

OSCILLATION 

The tower fan has horizontal oscillation. 

The oscillation can be set on any MODE, 

including humidification mode.
To activate oscillation, touch the   button 

once. The tower fan will move left to 

right continuously. 
To stop and direct the orientation of your 

tower fan during oscillation, touch the 

oscillation symbol again when the airflow 

has reached your preferred position. 

HUMIDIFICATION 

The Breville Mistic 2 in 1

TM

 Connect Tower 

Fan & Humidifier comes with the added 

benefit of humidification. The humidifier 

can be set on any MODE and emits a mist at 

the same time that the fan is operating. 
To fill the water container before use, press 

the water container release button found 

on the outside of the water container on the 

back of the tower fan and it will disengage 

for easy removal. Turn the water container 

upside-down and remove the water 

container cap. Fill the water container with 

fresh water and replace the water container 

cap before reassembling the water container 

(upright) back into the tower fan.
To activate the humidifier function, touch 

the   button once. The tower fan will 

automatically release mist on low from the mist 

nozzle. The   symbol will illuminate on the 

LED display screen before setting.
To increase the mist output from LOW to 

HIGH, touch the   button again. To turn 

the humidification off, touch the   button 

again, and the mist output will automatically 

stop.
Once the water container is empty, or the 

water level is too low, the   symbol will 

begin to flash. Refill the water in the water 

container and replace the water container 

into the tower fan. The   symbol will stop 

flashing and stay off. Humidification will 

need to be re-activated.

LTF408_ANZ_IB_D20.indd   15

LTF408_ANZ_IB_D20.indd   15

15/7/20   2:14 pm

15/7/20   2:14 pm

Содержание Mistic 2 in 1 Connect LTF408

Страница 1: ...1 Instruction Book Suits all LTF408 Models the Mistic 2 in 1 Connect Tower Fan Humidifier LTF408_ANZ_IB_D20 indd 1 LTF408_ANZ_IB_D20 indd 1 15 7 20 2 14 pm 15 7 20 2 14 pm ...

Страница 2: ...er plug of this tower fan When unpacking the tower fan check to see you have received all the items listed in the parts list before discarding the packaging Do not place the tower fan near the edge of a bench or table during operation Ensure that the surface is level clean and free of water and other substances Always ensure the tower fan is properly assembled before use Follow the instructions pr...

Страница 3: ...outlet Before leaving it unattended Before attempting to move the appliance Before cleaning and maintenance unless otherwise specified in this booklet Immediately after use To prevent damage to the tower fan do not use alkaline cleaning agents when cleaning Use a soft cloth and a mild detergent Do not place anything on top ofthetowerfanwhenassembled wheninuseorwhenstored The tower fan is not inten...

Страница 4: ...Do not pour water into any openings except for the water container When filling or refilling only fill the water container with cold tap water or distilled water Do not use ground water or hot water Always use clean tap or distilled water to prevent clogging and damage to the transducer Do not put any substance other tap water into the water container Do not add fragrance or any chemical substance...

Страница 5: ...is considered to be between 40 RH to 60 RH Empty any remaining water from the water container and water inlet basin when the humidifier is not in use The humidifier is not intended to be operated by means of an external timer or separate remote control system or any other device that switches the tower fan on automatically Keep the tower fan humidifier clean Follow the cleaning instructions provid...

Страница 6: ...with the appliance It is recommended to regularly inspect the appliance To avoid a hazard do not use the appliance if power cord power plug or appliance becomes damaged in any way Return the entire appliance to the nearest authorised Breville service centre for examination and or repair Any maintenance other than cleaning should be performed at an authorised Breville Service Centre This appliance ...

Страница 7: ...ce is not in use Before cleaning always turn the appliance to the OFF position switch off at the power outlet unplug at the power outlet and remove the power cord if detachable from the appliance and allow all parts to cool Do not place this appliance on or near a heat source such as hot plate oven or heaters Position the appliance at a minimum distance of 20cm away from walls curtains and other h...

Страница 8: ...tainer I Rear Housing J Water Outlet Cap K Control Panel L LED Display Screen M Remote Control NOT PICTURED Front Pivot Grille Cover Water Inlet Basin Water Container Cap and Seal Power Cord and Plug cComponents A B D C E F K L I H G J OSC HUMIDITY MODE TIMER M LTF408_ANZ_IB_D20 indd 8 LTF408_ANZ_IB_D20 indd 8 15 7 20 2 14 pm 15 7 20 2 14 pm ...

Страница 9: ...OWER ON OFF D OSCILLATION ON OFF E UP REMOTE CONTROL PANEL F TIMER G OSCILLATION ON OFF H POWER ON OFF I UP J DOWN K HUMIDITY L MODE OSC HUMIDITY MODE TIMER F K L G H I J A D E LTF408_ANZ_IB_D20 indd 9 LTF408_ANZ_IB_D20 indd 9 15 7 20 2 14 pm 15 7 20 2 14 pm ...

Страница 10: ...10 cDisplay Screen ECO MODE NIGHT MODE NATURAL MODE FAN SPEED AMBIENT TEMPERATURE HUMIDITY TIMER Wi Fi LTF408_ANZ_IB_D20 indd 10 LTF408_ANZ_IB_D20 indd 10 15 7 20 2 14 pm 15 7 20 2 14 pm ...

Страница 11: ...he first time remove all packaging material and promotional labels Check for any missing or damaged parts as per the components list ASSEMBLE THE BASE To assemble the base to the body of the tower fan turn the body upside down Align mark 1 on the base with mark 1 on the bottom of the body Fig 1 Fig 1 Mark 1 on the base Mark 1 on the unit body To lock the base to the body turn the base clockwise so...

Страница 12: ... humidifier however can be turned on or off to operate on fan only When the tower fan is ON Wi Fi will attempt to connect automatically If a connection has been made the Wi Fi symbol will stop flashing and illuminate If a connection is not made the Wi Fi symbol will stop illuminating See Wi Fi Connectivity in this book for more details After 15 hours of non stop operation the tower fan will automa...

Страница 13: ...lowest and 12 the highest with the default speed at 5 To choose a fan speed setting touch the and buttons on either the control panel or the remote until the desired number flashes on the LED display screen 3 times then sets NORMAL mode is the default mode settings for this tower fan In NORMAL mode no light illuminates on NATURAL NIGHT or ECO on the LED display screen NATURAL MODE Continuous air f...

Страница 14: ...r 6 hours AUTO ON TIMER Example Set the auto on timer to 6 hours and the tower fan will start operating after 6 hours To confirm the setting press the timer button again AUTO OFF TIMER Touch the button on the remote and will flash along with 0 5 on the LED display screen Touch the and buttons on either the control panel or the remote control until the desired number of hours flashes on the LED dis...

Страница 15: ...idification mode To activate oscillation touch the button once The tower fan will move left to right continuously To stop and direct the orientation of your tower fan during oscillation touch the oscillation symbol again when the airflow has reached your preferred position HUMIDIFICATION The Breville Mistic 2 in 1TM Connect Tower Fan Humidifier comes with the added benefit of humidification The hu...

Страница 16: ...er to the MODE and TIMER sections of this book for more details To avoid misplacing your remote control place the remote control between the carry handle and the controls of the tower fan frame USING THE REMOTE CONTROL Your remote control requires 2 x AAA batteries NOT INCLUDED To insert the batteries open the battery compartment at the back of the remote by forming a good grip of the remote and p...

Страница 17: ... corner of the screen Follow the prompts in the app 4 If the connection is successful the tower fan will appear in the main page of the app and the Wi Fi symbol light on the purifier will illuminate The Breville Mistic 2 in 1 Connect Tower Fan Humidifier can offer remote operation by using a home Wi Fi connection and the Breville Home Connect app downloaded to a compatible mobile phone through the...

Страница 18: ...t halfway Making sure the water container cap is replaced on the container swish the solution around for a minute then fill the rest of the container up with tap water Leave to sit for 1 2 hours or even overnight Empty and rinse well with clean water WATER INLET BASIN Build up of calcification may occur in the water inlet basin and should be removed and cleaned to ensure optimum performance Remove...

Страница 19: ...water flowing or splashing into the internals of the unit possibly damaging the internal electrical parts STORAGE When not in use store the tower fan upright in a cool clean and dry location LTF408_ANZ_IB_D20 indd 19 LTF408_ANZ_IB_D20 indd 19 15 7 20 2 14 pm 15 7 20 2 14 pm ...

Страница 20: ...ks of Breville Pty Ltd Android is a trademark of Google LLC All other brands may be trademarks of their respective owners Breville s products are distributed in New Zealand under license A B N 98 000 092 928 Due to continued product improvement the products illustrated photographed in this booklet may vary slightly from the actual product LTF408 ANZ D20 LTF408_ANZ_IB_D20 indd 20 LTF408_ANZ_IB_D20 ...

Отзывы: