TO CLEAN EXTERNAL PARTS

1.  Use a clean, dry cloth to clean all external 

surfaces of the humidifier.

2.  A soft, slightly-damp cloth may be used to 

wipe the external housing of the humidifier 

if more thorough cleaning is required. Do 

not allow any water to come in contact with 

the control buttons. Never use chemical 

substances or scourers as this could damage 

the housing and the button controls.

3.  Dry thoroughly before storing or using the 

humidifier.

TO CLEAN INTERNAL PARTS

1.  To clean internal parts of the humidifier,  

create a cleaning solution of 1-part vinegar  

to 1-part water.

WATER TANK 

1.  It is important to clean the water tank 

regularly and ensure it is thoroughly  

dry before using the humidifier. 

2.  To clean, create a vinegar and water solution 

enough to fill the tank about half way. Making 

sure the cap is replaced on the tank, swish the 

solution around for a minute. Fill the rest of 

the tank up with tap water, replace the cap  

and then let sit for 1–2 hours, or even 

overnight, before emptying.

3.  Empty and rinse well with clean or distilled 

water.

4.  Allow the water tank time to dry thoroughly 

before using the humidifier.

NOTE

To assist with emptying all the water from the 

water tank, it may help to slightly shake the tank 

over a sink or drain.

MIST NOZZLE

1.  If the mist output is declining due to 

calcification, turn the cover over and immerse 

the nozzle in a vessel filled with a vinegar and 

water solution and soak for a period, or at least 

10 minutes.

2.  Rinse well with clean or distilled water  

and allow to dry.

WATER INLET BASIN

1.  The water inlet basin includes the water 

reservoir in the base of the unit that also 

houses the transducer and the heating 

element.

2.  Clean the water basin with a soft cloth. If there 

is excess film or calcification on the surface, 

then soak the cloth with the vinegar and water 

solution and repeat the process.

3.  If there is film or calcification in any of the 

depressions along the basin, drop a bit of 

vinegar and water solution into the depression 

and lightly clean it with the brush provided or 

a cotton swab.

4.  Rinse well with clean or distilled water  

and allow to dry.

OPTIONAL CLEANING SOLUTION 
FOR CALCIFICATION ISSUES

1.  If a build-up of calcification on the transducer 

or heating element occurs and cannot 

be removed with a simple vinegar and 

water solution, use a de-calcifying agent 

or citric acid. STRICTLY FOLLOW THE 

INSTRUCTIONS ON THE PACKAGING 

FOR THESE CLEANING PRODUCTS.

2.  Brush off any scale deposits from the 

transducer and heating element surfaces 

using the brush provided or a cotton swab.

3.  Rinse well with clean or distilled water and 

allow to dry.

IMPORTANT

Never use sharp or solid objects to clean the 

transducer and heating element. Avoid touching 

the transducer and heating element with your 

fingers. 

NOTE

The heating element in the base of the humidifier 

will lose its stainless steel finish over time; this 

is normal. It is still recommended to de-calcify 

as per instructions noting that cleaning may not 

bring it back to its original shine.

STORAGE

• 

Never store the humidifier with water in the 

unit.

• 

Clean as per instructions and make sure that all 

parts are dry before storing.

• 

Keep the humidifier in a dry cool place.

• 

Do not place anything on top of the humidifier.

Содержание Easy Mist LAH300

Страница 1: ...the Easy MistTM Humidifier Instruction Book LAH300...

Страница 2: ...ny packaging material and promotional labels before using the humidifier for the first time To eliminate a choking hazard for young children remove and safely discard the protective cover fitted to th...

Страница 3: ...cations Never place the humidifier where it may fall into a bath or other water container Do not use or store where it may get wet or in the immediate surroundings of a bath a shower or a swimming poo...

Страница 4: ...me clean and dry the water tank before storage Clean the water tank every week Always disconnect the humidifier from the power supply and empty the water tank before moving Always carry the humidifier...

Страница 5: ...NT SAFEGUARDS FOR ALL ELECTRICAL APPLIANCES Fully unwind the power cord before use Connect only to a 230V or 240V power outlet Do not let the power cord hang over the edge of a bench or table touch ho...

Страница 6: ...should be disconnected from the power source at the wall socket to prevent any electrical surges that may arise during the storm and which may inadvertently cause damage to the appliance and its elec...

Страница 7: ...r Level Window E Water Tank F Water Tank Cap G Aroma Tray H Air Outlet I Water Buoy J Cleaning Brush K Power Indicator Light L Water Inlet Basin M Heating Element N Transducer O Power Cord NOT PICTURE...

Страница 8: ...8 MIST LEVEL POWER WARM MIST Control Panel A Power On Off B Mist Level C Warm Mist C A B...

Страница 9: ...components list 3 Clean all parts according to the Care Cleaning Storage section 4 Place the humidifier on a flat surface that will not be damaged by exposure to water or moisture IMPORTANT It is rec...

Страница 10: ...o increase to medium mist intensity There will be one beep and the mist level light will turn blue Press again to increase to high mist level intensity There will be one beep and the light will turn g...

Страница 11: ...n on the surface of transducer will reduce the reliability of the unit WARM MIST This humidifier has a warm mist feature When selected a small internal heating element will heat the water to create a...

Страница 12: ...o dry WATER INLET BASIN 1 The water inlet basin includes the water reservoir in the base of the unit that also houses the transducer and the heating element 2 Clean the water basin with a soft cloth I...

Страница 13: ...essential oil used is not the cause of the odour and or too much oil has been added Abnormal noise Vibration in the water basin because the water level is too low Fill the water tank with clean water...

Страница 14: ...14 NOTE...

Страница 15: ...15...

Страница 16: ...ville Customer Service Centre Breville the Breville logo Master Every Moment and Easy Mist are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2019 Due to continued prod...

Отзывы: