12

Care, Cleaning  
& Storage

WARNING

Before cleaning or maintenance of the 

dehumidifier, ensure the power is switched  

off at the outlet, and the plug is removed.

CLEANING YOUR DEHUMIDIFIER

1.  Keep the unit upright when cleaning
2.  Wipe the dehumidifier housing, control 

panel, and air inlet and outlet grilles with  

a soft, dry cloth.

3.  To remove dirt that has built up heavily, 

wipe with a slightly damp cloth only. 

WARNING

Do not clean the control panel with a damp 

cloth. Do not clean the unit with gasoline, 

thinner or liquid detergent as chemical 

substances may damage the humidifier screen 

or change the colour of the dehumidifier.

NOTE

Using a brush may scratch the dehumidifier. 

Do not use any objects that may scratch  
the unit.

WATER TANK CLEANING 

NOTE

The dehumidifier cannot operate if the tank is 

full or is not installed correctly.
Clean the water tank once a week if used 

regularly.
1.  Using the handle, slide the water tank 

out and away from the dehumidifier, then 

remove the water tank cover from the tank.

2.  Tip any water in the water tank into a drain.
3.  Rinse the inside of the tank with clean 

water.

4.  Wipe any excess water from the outside of 

the tank and the dehumidifier with a soft, 

dry cloth.

5.  Place the water tank cover back on the  

water tank and then slide the tank back into 

the dehumidifier.

FILTER CLEANING

Clean the filter at least monthly, or more often 

if the dehumidifier is in frequent use.

NOTE

A dirty filter may cause a reduction in 

the performance of the dehumidifier. 

Clean regularly.

1.  To access and clean the dust filter, remove 

the air inlet grille from the back of the 

dehumidifier.

2.  Separate the mesh dust filter form the grille.
3.  Use a hand-tool on a vacuum cleaner (such 

as a brush or upholstery tool) to clean the 

dust from the filter or wash in soapy water. 

Ensure the filter is dry before replacing.

4.  Replace the dust filter back on the air inlet 

grille, then replace on to the dehumidifier.

STORAGE

1.  Disconnect the dehumidifier from the 

power outlet.

2.  Ensure the water tank is empty and cleaned 

as per instructions.

3.  Clean the dehumidifier as per instructions.
4.  Store the dehumidifier upright and avoid 

standing in direct sunlight if leaving for 

long periods.

5.  Never store anything on top of the 

dehumidifier.

Содержание All Climate LAD250

Страница 1: ...the All Climate Dehumidifier Instruction Book LAD250 ...

Страница 2: ...d promotionallabelsbefore usingthedehumidifier for the first time Toeliminateachokinghazard foryoungchildren removeand safelydiscardtheprotective coverfittedtothepower plug ofthisdehumidifier Whenunpackingthe dehumidifier checktoseeyou havereceivedalltheitems listedinthepartslistbefore discardingthepackaging Thedehumidifier isintended forhouseholduseonlyandnot forcommercialor industrial use Donotu...

Страница 3: ...ifierhas beendroppedordamaged inanymanner Returnthe dehumidifierto yournearest Brevilleservice centrefor examination electrical ormechanicaladjustment orrepair Donotusethedehumidifier withanexternaltimer programmer oranyother devicethatswitchesthe dehumidifieronautomatically sinceafireriskmayexistifthe dehumidifieriscovered orpositionedincorrectly Donotplaceanythingon topofthedehumidifierwhen asse...

Страница 4: ...din thecleaninginstructions Theapplianceisnotintended forusebypersons including children withreducedphysical sensoryor mentalcapabilities orlackofexperienceand knowledge unlesstheyhave beengivensupervisionor instructionconcerninguse oftheappliancebyaperson responsiblefortheir safety Childrenshouldbesupervised toensurethattheydonotplay withtheappliance Itisrecommendedtoregularly inspecttheappliance...

Страница 5: ...anceanditselectronic componentry Alwaysturntheapplianceto theoffposition switchoffat thepoweroutletandunplug atthepoweroutlet whenthe applianceisnotinuse FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS Beforecleaning alwaysturn theappliancetotheoff position switchoffatthe poweroutlet unplugatthe poweroutletandremovethe powercord ifdetachable fromtheapplianceandallow allpartstocool Donotplacethisapp...

Страница 6: ...dy D Water Level Window E Base F Carry Handle G Air Inlet and Filter H Continuous Drainage Outlet Hole I Water Tank Not Pictured Drainage Hose gravity assisted Power Cord Water Tank Cover Continuous Drainage Outlet Dust Filter A B C D F G H I E Front Back ...

Страница 7: ...ED HIGH 40 50 60 CONTINUOUS 1H ON 2H 4H 8H SPEED HUMIDITY ION FILTER TIMER Control Panel A Power On Off B Fan Speed C Humidity Setting D Timer G F A B C D E E Ion Filter On Off F Overheat Warning Light G Empty Me Warning Light ...

Страница 8: ...a percentage of the maximum amount of water vapour that the air can hold at a given temperature A comfortable RH level is between 40 60 RH Assembly BEFORE FIRST USE 1 Before using your dehumidifier for the first time remove all packaging material and promotional labels 2 Check for any missing or damaged parts as per the components list 3 Clean all parts according to the Care Cleaning Storage secti...

Страница 9: ...ty on the selected humidity level HUMIDITY SETTING The default humidity setting for this dehumidifier is CONTINUOUS The Humidity Setting allows you to manually set the relative humidity RH level between 40 50 60 and CONTINUOUS To select the humidity level press the HUMIDITY button until the light illuminates next to the desired level When the selected humidity level is reached the dehumidifier wil...

Страница 10: ...not suitable for drinking Do not drink this water and do not serve to animals or use to water plants NOTE Ensure the water tank is fitted correctly or the dehumidifier will not operate ION FILTER The inoniser produces charged negative ions that attach to floating particles such as dust and allergens removing them from the air 1 Press the ION FILTER button to turn the ioniser On or Off TIMER If a t...

Страница 11: ...ose should be above the level of the continuous drainage outlet WARNING Ensure the hose is secure in both the water outlet and the drainage outlet OVERHEAT WARNING This dehumidifier is equipped with Overheat Protection As the dehumidifier operates an obstruction blockage may occur in the air grilles causing the unit to overheat internally In this event the dehumidifier will turn off automatically ...

Страница 12: ...er in the water tank into a drain 3 Rinse the inside of the tank with clean water 4 Wipe any excess water from the outside of the tank and the dehumidifier with a soft dry cloth 5 Place the water tank cover back on the water tank and then slide the tank back into the dehumidifier FILTER CLEANING Clean the filter at least monthly or more often if the dehumidifier is in frequent use NOTE A dirty fil...

Страница 13: ... object that is blocking the air inlet or outlet Loud noises coming from the dehumidifier The dehumidifier is on an uneven surface Position the dehumidifier on a smooth and stable surface The dehumidifier suddenly stops The room temperature may be outside of the radar of the dehumidifier The dehumidifier will start automatically when it can read the room temperature again Clothing dries very slowl...

Страница 14: ...14 Notes ...

Страница 15: ...15 Notes ...

Страница 16: ...e Customer Service Centre Breville the Breville logo Master Every Moment All Climate and SenSair are trademarks of Breville Pty Ltd A B N 98 000 092 928 Copyright Breville Pty Ltd 2019 Due to continued product improvement the products illustrated photographed in this booklet may vary slightly from the actual product LAD250 ANZ A19 ...

Отзывы: