Brett Dempsey Engineering TH400 Скачать руководство пользователя страница 4

 

When all four bolts are installed and snug, verify that none of the back o-rings have 
become dislodged, preventing the adapter from sitting flat on the pump surface.   

 

     

  

Figure 5 – 

Machined housing and pump face

              Figure 6 – 

Adapter installed, torque sequence 

 

 

Torque the bolts using a 3/16” Allen drive socket to 18 ft- lbs (see Figure 6 for torque 
sequence) and wipe off any excess grease. 

 

Install the small o-rings into the remaining four (4) front adapter pockets (Figure 4), 
smear some grease onto these so the bolts don’t tear them during assembly. 

 

Bellhousing 

 

Place the bellhousing onto the adapter and rotate into position (sight through bolt 
holes 5, 6, 7, and 8 [Figure 7] which index the entire assembly). 

 

 

       Figure 7 – 

ZD30 bellhousing installed, long bolt torque sequence

           