background image

18 / 24

31 Dew point

Press the INDEX button several times until DEW POINT is displayed.

Note:

The dew point is the temperature below which the water vapor in air at constant barometric pressure
condenses into liquid water at the same rate at which it evaporates. The condensed water is called
dew when it forms on a solid surface. The dewpoint temperature is calculated from the indoor temper-
ature and humidity measured at the main unit.

32 History record for the past 24 hours

The base station automatically records and displays data of the past 24 hours.

1. Press the HISTORY button to check history records of the last hour.

2. Press the HISTORY button several times to display the history records of the hours 2,3,4,5 ......

33 MAX/MIN Weather data

The base station preserves the MAX/MIN weather data records until the next manual reset. To retrieve
the data:

1. Press MAX/MIN button several times to display the stored values one after another.

2. Display order: Outdoor max temperature > Outdoor min temperature > Outdoor max humidity >

Outdoor min humidity > Indoor max temperature > Indoor min temperature > Indoor max humidity
> Indoor min humidity > Outdoor max wind chill > Outdoor min wind chill > Outdoor max heat index
> Outdoor min heat index > max dew point > min dew point > max pressure > min pressure > max
average > max gust > max rainfall

3. Press MAX/MIN button for approx. 2 seconds to delete all saved values.

34 Technical data

Base station

Power supply:

4x AA, 1.5V

Temperature measuring range

from -5°C to 50°C

Dimensions

224 x 224 x 23 mm (W x H x D)

Weight (incl. batteries)

780 g

Multisensor

Batteries

3x AA, 1.5V

Maximum number of sensors

1x wireless multisensor

Transmission frequency

868Mhz

RF Transmission range

150 m

Maximum radio-frequency power

< 25mW

Temperature measuring range

from -40°C to 60°C (from -40°F to 140°F)

Barometer measuring range

From 540 to 1100hPa (relative range: from 930 to
1050hPa)

Air humidity measuring range

From 1 to 99%

Humidity resolution

1% HR

Precipitation measuring range

From 0 to 9999 mm (from 0 to 787.3 inch)

Wind speed measuring range

From 0 to 112 mph, 50 m/s, 180km/h, 97 knots

Dimensions

343.5 x 393.5 x 136 mm (W x H x D)

Weight (incl. batteries)

673g

Содержание Weather Center XXL JC + sensor 5in1

Страница 1: ...Weather Station Weather Center XXL JC sensor 5in1 EN Instruction manual...

Страница 2: ...ant le code QR ou le lien correspondant NL Bezoek onze internetpagina via de volgende QR code of weblink voor meer informatie over dit product of de beschikbare vertalingen van deze gebruiksaanwijzing...

Страница 3: ...14 Automatic time setting 11 15 Manual time setting 11 16 Time zone setting 11 17 Receiving measurements automatically 12 18 Receiving measurements automatically 12 19 Rainfall 12 20 Manual measuremen...

Страница 4: ...4 35 EC Declaration of Conformity 19 36 Cleaning and maintenance 19 37 Disposal 19 38 Warranty 20...

Страница 5: ...in this documentation are gen erally protected by trade trademark and or patent law in Germany the European Union and or other countries 2 Validity note This documentation is valid for the products wi...

Страница 6: ...button switch between highest low est or current value display 5 HISTORY button retrieve measurements for the past 24 hours 6 UP button increase value 7 DOWN button decrease value 8 TIME button manua...

Страница 7: ...meter 7 Pipe clamp 8 Mounting shoe 9 Mounting bar 10 Battery compartment cover 11 RESET button 12 LED function indicator 13 Mounting screws with nuts 7 Scope of delivery Base station A power adapter B...

Страница 8: ...ls like temperature wind chill dew point and heat index 14 Beaufort scale for wind force classification 15 Outdoor humidity 16 Sensor signal strength indicator 17 Outdoor temperature 18 Weather foreca...

Страница 9: ...ote that the effective range is vastly affected by building materials and position of the main and re mote units Due to external influences various RC devices and other sources of interference the max...

Страница 10: ...nt to the North Assembly on a vertical or horizontal wooden element 1 Slide one end of the assembly bar into the aperture below the sensor head 2 Slide one screw through the bore hole and put on the n...

Страница 11: ...signal icon turns on If the clock fails to receive the time signal go ahead with the following steps 1 Press RCC button on the base station until radio signal symbol flashes 2 If the device is still...

Страница 12: ...rainfall Monthly rainfall Select display mode Press the RAIN key repeatedly until the desired time period is shown on the display RATE Current precipitation of the last hour DAILY Total precipitation...

Страница 13: ...ut a need to reset the clock and re establish pairing Simply press and hold the HIS TORY button for 10 seconds This will clear out any data recorded before 23 Pointing the sensor to the south The sens...

Страница 14: ...n hemisphere it moves from left to right Below are the 2 tables which illustrate how the moon will appear on the main unit A 1 2 3 4 5 6 7 8 B 1 2 3 4 5 6 7 8 Illustration 4 A Northern hemisphere B So...

Страница 15: ...next setting value 5 Press the UP or DOWN key to change the REL value according to the researched value 6 Finally press the CLOCK SET button to save the settings and exit the setting mode NOTICE ABS...

Страница 16: ...88 km h 88 km h Select wind speed unit 1 Press the WIND button for approx 3 seconds to enter the setting mode 2 Press the UP or DOWN button to change the unit between mph miles per hour m s miles per...

Страница 17: ...CHILL is displayed Note The wind chill factor is based on the common effects of temperature and wind speed The displayed wind chill is calculated solely from temperature and wind speed and is measured...

Страница 18: ...Outdoor min temperature Outdoor max humidity Outdoor min humidity Indoor max temperature Indoor min temperature Indoor max humidity Indoor min humidity Outdoor max wind chill Outdoor min wind chill O...

Страница 19: ...hermo hygro sensor 5 Unscrew the 2 screws at the bottom of the radiation shield 6 Gently pull out the shield 7 Remove carefully any dirt or insects inside the sensor casing Note The radiation shield c...

Страница 20: ...hargeable batteries are marked with a symbol of a crossed out dustbin and the chemical symbol of the pollutant Cd stands for Cadmium Hg stands for mercury and Pb stands for lead 38 Warranty The regula...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...ail sav bresser fr T l phone 00 800 6343 7000 BRESSER France SARL P le d Activit s de Nicopolis 260 rue des Romarins 83170 Brignoles France Prix d un appel local depuis la France ou Belgique Service N...

Отзывы: