3-1 INTRODUCTION
Periodic maintenance, inspection and cleaning will help insure the ALT 170C is kept at
full readiness.
3-2 CLEANING
1. Brush loose dirt and dust from the charger. Low-pressure air may be used to
remove heavy dust from the case, connectors and power switches. Avoid
blowing dust into the unit. Low-pressure air may be blown into the left and right
air vents at the edge of the control panel to help remove internal dust.
2. Wipe surfaces with a damp (not wet) rag. Non-solvent cleaners maybe used
(Windex™, Fantastix™, 409™). Do not spray or drip water or cleaners onto the
panel or into the connectors.
3. The flush mounted adapter connectors may be cleaned with electronic grade
spray cleaner. Allow the cleaner to dry before installing the adapters or
applying power to the charger.
4. The connections on the Adapters may be cleaned with electronic grade spray
cleaner or isopropyl alcohol. Insure the Adapters are dry before using them.
.
3-3 INSPECTION
1. Inspect case for cracks and other damage.
2. Insure the lid gasket is in place.
3. Insure the Hinge Pins are fully inserted.
4. Insure the lid closes and can be properly latched.
5. Insure all Screws are in place and are not loose.
6. Inspect the panel and connectors for damage.
7. Inspect all adapters for excessive wear and damage.
a. Inspect charger connector for bent or corroded pins.
b. Inspect battery connector pins for damage or corrosion.
c. Insure all spring pins are not bent and move freely.
d. Note that spring pins can be removed and replaced.
8. Inspect power cords for damage.
9. Insure power switches move freely.
10. Insure the pressure equalization valve, located near the carrying handle is
snugly tightened.