28
9.3 Waste connection
D
Install an anti syphon trap to the drain connection.
D
Drain run must coply with national standards.
D
Seal the drain hosepipe at the outlet pipe and fix it.
D
The inlet and outlet hosepipes must not be twisted or crushed.
9.4 Electrical connections
D
CAUTION! The electrical connections must be carried out by a licenced
electrical installation engineer
- in accordance with the applicable national regulations and
- according to the regulations of the respective concerned power supply
company.
D
The connecting flex must be at least in accordance with national standards (H07
RN-F / 245 IEC 66).
D
The electrical switch (mains switch)
- must be mounted at an easily accessible location by the installing party.
- The switch must isolate the bremer VIVA XXL-T effectively with all phases
breaking from the electrical mains-network.
- For that, the contact opening must be (at least 3 mm) in accordance with
national standards.
D
Ensure that the machine is integrated at
the equalisation system / earth
conductor.
D
Pay attention to the data plate for the
correct electrical connection!
Earth clamp