10.
Install the UL listed junction box with terminal block inside of the lower pedestal (skip this step if it is factory
installed). Pull the incoming power wires into the UL listed box and properly terminate them to the terminal
block.
11.
Bring incoming power feed wires into the UL listed box, terminate them to the terminal block, attach cover
to UL listed box and attach front cover to lower pedestal. Attach J1772 holsters in proper locations
(depending on single, dual, or side by side install). Install non-cable management rain cover to the top of
the pedestal. Install provided black plastic hole covers to fill any unused holes in the pedestal for a clean
appearance.
12.
Wrap charging cables around the chargers for clean appearance.