Release Note: BreezeNET PRO.11 

Version 4.4 

 

General

 

BreezeCOM is pleased to announce the release of BreezeNET Version 4.4. This version adds the 
following features to the BreezeNET product line: Authentication and power save. Better 
accommodation for the wide range of countries where BreezeNET is used (see Hopping Standard 
and DL unit). Please find below a description of these new features, and others that are specific for 
the BreezeNET units and the SA-PCR.

 

An updated BreezeVIEW management application is now available. 

 

Authentication

 

Wired Equivalent Privacy (WEP) authentication algorithm protects authorized Wireless LAN users 
against eavesdropping and access by un-authorized users. When enabled in an AP-10, only a station 
adapter that has the privacy option implemented and an identical encryption key will be able to 
associate to the access point. Authentication has been implemented as defined in the 802.11 

 

This feature is an orderable option. You can either order a BreezeNET unit (including SA-PCR) with 
the privacy option factory installed, or you can upgrade to add the Privacy feature to existing units, it 
is also possible to return the units to BreezeCOM for upgrading. 

 

When ordering new units or upgrading existing ones please use the following catalog numbers for the 
Privacy option:

 

811104   For AP-10, WB-10, SA-40 and SA-10

 

811105   For SA-PCR

 

The authentication parameters are configurable using the monitor or a SNMP management station. 

 

Power Save 

 

Power Save mode is primarily intended for the SA-PCR, usually installed on laptops or handheld 
computers, in order to conserve battery energy. The Power Save mode allows the SA-PCR to go into 
a Doze state for a predefined period that will reduc e the PCMCIA power consumption. The settings 
for this option are made per cell and per station. Power Save needs to be configured in both the AP-
10 and the SA-PCR. Performance of the whole cell will be effected even if only the AP and one 
station are set to Power Save Mode. 

 

Power Save Mode has been implemented as defined in the 802.11 standard. The power save in the 
AP also works with Symbol's station adapter.

 

Country Standards Support

 

The BreezeNET PRO.11 including the PC card can now be ordered for the following standards:

 

US, Europe, Japan, France, Canada, Russia (Site proprietary), Australia, 
Netherlands, Israel, Spain, Korea

 