WKCE 05/11 PG 4 

 

warm air exhaust includes unventilated small rooms, closets, bathrooms, hot garages, unventilated crawl 
spaces, attics and humid basements. 

 

  Make sure that the warm air exterior grille can be properly attached to the unit (see Fig. 3). 

 

  Make a hole through the wall as illustrated in Fig. 2.  Construct a shelf as shown in Fig. 3.  This shelf 
must be capable of supporting the weight indicated in the specifications.  NOTE: Insulation placed 
between the unit and the shelf will reduce noise and help reduce condensate from forming on the 
underside of the unit. 

 

If your installation cannot be performed in accordance with these instructions contact your 
dealer.

 

  Place the unit through the opening with the exhaust side flush to the outside wall.  Attach the warm side

 

exterior grille (Fig. 1&3) to unit and wall with screws supplied.  Please remember that in 

all

 cases the exterior 

grille must be directly attached to the warm side of the unit. 

 Do not

 leave an air gap between the unit's 

surface and the exterior grille.  

The unit will

 

not

 work properly without this grille.  

The warm side exterior 

grille has only a white primer coat.  If the grille is installed on an outside wall it should be coated with an 
appropriate paint to prevent rust.  

OPERATION 

  On initial start-up the cooling unit will reduce the temperature of the enclosure slowly.  The unit may run 
constantly or cycle off for short periods.  The time required to reach the desired temperature will vary, 
depending on the enclosure's construction and contents. 

  The thermostat is factory set to 55o Fahrenheit.  Unless the temperature falls below that desired, do not 
change the thermostat setting for at least 3 days. 

  During normal operation of the Sentry III thermostat the LED readout will display the temperature of the air 
entering the intake of the cooling unit.  If the optional bottle probe is installed the intake air sensor will be 
disconnected and the temperature of the probe will be displayed.  The temperature being displayed is also the 
temperature used by the control system to turn the cooling unit on and off. 

  After initial cool down, the "on-off" cycle should be relatively constant.  The percentage of "off " time will 
depend on enclosure's construction, placement of unit, contents, and surrounding outside temperatures.  If it 
is necessary to adjust the temperature of the enclosure; adjust the thermostat to a colder temperature while 
the unit is running and to a warmer temperature while the unit is off.  The set point may be set no lower than 
48°F or higher than 62°F.  NOTE:  If the enclosure is not cooling to the current set point, lowering the set point 
temperature further will not help. (See ENCLOSURE PROBLEMS section)   

  The Sentry III set point (desired enclosure temperature) may be changed by pressing and holding the "SET" 
button while pressing the "COOLER" or "WARMER" button.  When the "SET" button is pressed the readout 
will automatically change and display the current set point temperature 